Technical Data Sheet
7-16
Calibration Kit
Full Version
60CK001-150
Picture may differ from original product
Contents
Device
Open circuit plug
Open circuit jack
Short circuit plug
Short circuit jack
Calibration load plug
Calibration load jack
Calibration adaptor plug/plug
Calibration adaptor jack/jack
Calibration adaptor RPC-N
plug to 7-16 plug
Calibration adaptor RPC-N
jack to 7-16 jack
Combi wrench
Torque wrench
Gauge jack
(including gauge block)
Part number
60S12L-000S3
60K12L-000S3
60S12S-000S3
60K12S-000S3
60S150-C10S3
60K150-C10S3
60S121-S20S3
60K121-K20S3
05S160-S20S3
05K160-K20S3
60W013-000
60W000-003
60W00K-000
60W00S-000
Quantity
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Calibration Option
a
FC / AC
FC / AC
FC / AC
FC / AC
FC / AC
FC / AC
FC / AC
FC / AC
FC / AC
FC / AC
-
FC
FC
FC
Gauge plug
a.
(including gauge block)
See “Declaration of calibration options” for explanation.
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Fax : +49 8684 18-499
Email : info@rosenberger.de
Page
1/3
Technical Data Sheet
7-16
Calibration Kit
Full Version
60CK001-150
Documentation
This
kit is delivered with
•
USB-Stick
Standard Definitions as data files for Vector Network Anaylzer Families PNA (Keysight/Agilent) and ZVA
(Rohde&Schwarz). Calibration Certificate as PDF-file.
•
Standard Definitions Cards
Printed Standard Definitions that can be used on nearly all Vector Network Analyzers.
•
Kit Info Card
Handling precautions and information for installing Standard Definitions on a Vector Network Analyzer.
•
Calibration Certificate
Details see “Declaration of calibration options”
•
Operating Manual
Electrical specifications
This specification covers electrical key values for the main calibration standards of the calibration kit.
Specific datasheets are available for each component among the part number.
Calibration standard
b
Frequency
DC
> 4 GHz
DC
> 4 GHz
DC
> 4 GHz
DC
> 4 GHz
DC
> 4 GHz
DC
> 4 GHz
to
to
to
to
to
to
to
to
to
to
to
to
≤
4 GHz
≤
8 GHz
≤
4 GHz
≤
8 GHz
≤
4 GHz
≤
8 GHz
≤
4 GHz
≤
8 GHz
≤
4 GHz
≤
8 GHz
≤
4 GHz
≤
8 GHz
Parameter
Error from
Nominal Phase
Error from
Nominal Phase
Specification
≤
1.0°
≤
1.5°
≤
1.0°
≤
1.5°
≥
40 dB
≥
38 dB
≥
40 dB
≥
36 dB
≥
38 dB
≥
34 dB
≥
36 dB
≥
33 dB
Opens
(plug and jack)
Shorts
b
(plug and jack)
Calibration loads
(plug and jack)
Return Loss
Calibration adaptors
(plug/plug)
Return Loss
Calibration adaptors
(jack/jack)
Return Loss
Calibration adaptors
RPC-N to 7-16
(plug/plug and jack/jack)
b.
Return Loss
The specifications for opens and shorts are given as allowed deviation from nominal model as defined in calibration certificate
included with your kit.
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Fax : +49 8684 18-499
Email : info@rosenberger.de
Page
2/3
Technical Data Sheet
7-16
Calibration Kit
Full Version
60CK001-150
Declaration of calibration options
Factory Calibration
Standard delivery for this kit includes a Factory Calibration. All devices marked with “FC” in the Content
table above are reported in a Calibration Certificate with their individual calibration results, traceable to
national / international standards. Model based definitions of the calibration standards are reported in
Agilent/Keysight, Rohde & Schwarz and Anritsu compatible VNA format.
Accredited Calibration
Optional this kit can be delivered with an Accredited Calibration (DAkkS) having the highest confidence in
the traceability. All devices marked with “AC” in the Content table above are reported in a DAkkS Calibration
Certificate with their individual calibration results in a complex format, traceable to national / international
standards. Model based definitions of the calibration standards are reported in Agilent/Keysight, Rohde &
Schwarz and Anritsu VNA format as well as in dense data sets needed for data based calibration kits. The
uncertainties are a little bit smaller than in a Factory Calibration.
All devices marked with “FC” only cannot be calibrated under accreditation. They are factory calibrated as
described above.
For further, more detailed information see application note AN001 on the Rosenberger homepage.
Calibration interval
Recommendation
12 months
Recommended accessories
- Rosenberger Test Port Adaptor
- Rosenberger VNA Test cable kit and Microwave Cable Assemblies
For further, more detailed information please visit our homepage
www.rosenberger.com.
While the information has been carefully compiled to the best of our knowledge, nothing is intended as representation or warranty on
our part and no statement herein shall be construed as recommendation to infringe existing patents. In the effort to improve our
products, we reserve the right to make changes judged to be necessary.
Draft
Martin Moder
Date
12.10.15
Approved
H. Babinger
Date
01.08.16
Rev.
b00
Engineering change number
16-1267
Name
M. Knoll
Date
01.08.16
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Fax : +49 8684 18-499
Email : info@rosenberger.de
Page
3/3