Technical Data Sheet
P-SMP
Calibration Kit
Industrial Version
119CK010-150
Dieses Dokument ist urheberrechtlich geschützt ● This document is protected by copyright ● Rosenberger Hochfrequenztechnik GmbH & Co. KG
Contents
Device
Open circuit plug
Open circuit jack
Short circuit plug
Short circuit jack
Calibration load plug
Calibration load jack
Calibration adaptor plug/plug
Calibration adaptor jack/jack
Calibration adaptor plug/jack
Calibration adaptor
RPC-3.50 plug to SMP plug
Calibration adaptor
RPC-3.50 jack to SMP jack
a.
Part number
119S12L-000D3
119K12L-000D3
119S12S-000D3
119K12S-000D3
119S150-C10D3
119K150-C10D3
119S101-S20D3
119K101-K20D3
119S101-K20D3
03S119-S20S3
03K119-K20S3
Quantity
1
1
1
1
1
1
1
1
1
1
1
Calibration Option
a
FC
FC
FC
FC
FC
FC
FC
FC
FC
FC
FC
See “Declaration of calibration options” for explanation.
RF_35/05.10/6.1
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Fax : +49 8684 18-499
Email : info@rosenberger.de
Page
1/3
Technical Data Sheet
P-SMP
Calibration Kit
Industrial Version
119CK010-150
Documentation
This
kit is delivered with
•
USB-Stick
Standard Definitions as data files for Vector Network Analyzer Families PNA (Keysight/Agilent) and ZVA
(Rohde&Schwarz). Calibration Certificate as PDF-file.
•
Standard Definitions Cards
Printed Standard Definitions that can be used on nearly all Vector Network Analyzers.
•
Kit Info Card
Handling precautions and information for installing Standard Definitions on a Vector Network Analyzer.
•
Calibration Certificate
Details see “Declaration of calibration options”
•
Operating Manual
Dieses Dokument ist urheberrechtlich geschützt ● This document is protected by copyright ● Rosenberger Hochfrequenztechnik GmbH & Co. KG
Electrical specifications
This specification covers electrical key specifications for the calibration standards of the calibration kit.
Specific and more detailed datasheets are available for each kit device among the part number.
Calibration standard
DC
>4
DC
>4
DC
> 4
DC
>4
DC
>4
> 10
> 18
Frequency
to
to
to
to
to
to
to
to
to
to
to
to
4 GHz
10 GHz
4 GHz
10 GHz
4 GHz
10 GHz
4 GHz
10 GHz
4 GHz
10 GHz
18 GHz
26.5 GHz
Parameter
Error from
Nominal Phase
Error from
Nominal Phase
Specification
2.0
4.0
2.0
4.0
38 dB
26 dB
30 dB
26 dB
32 dB
28 dB
23 dB
19 dB
Opens
b
(plug and jack)
Shorts
b
(plug and jack)
Calibration loads
(plug and jack)
Return Loss
Calibration adaptors
(plug/plug , jack/jack, plug/jack)
Return Loss
Calibration adaptors
RPC-3.50 to P-SMP
(plug/plug and jack/jack)
Return Loss
b.
The specifications for opens and shorts are given as allowed deviation from nominal model as defined in calibration certificate
included with your kit.
RF_35/05.10/6.1
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Fax : +49 8684 18-499
Email : info@rosenberger.de
Page
2/3
Technical Data Sheet
P-SMP
Calibration Kit
Industrial Version
119CK010-150
Declaration of calibration options
Factory Calibration
Standard delivery for this kit includes a Factory Calibration. The Calibration Certificate issued reports
individual calibration results,
traceable to Rosenberger standards,
national / international standards are
not available. Model based standard definitions of the calibration standards are reported in Agilent/Keysight,
Rohde & Schwarz and Anritsu compatible VNA format.
Accredited Calibration
Not available.
For further, more detailed information see application note AN001 on the Rosenberger homepage.
Dieses Dokument ist urheberrechtlich geschützt ● This document is protected by copyright ● Rosenberger Hochfrequenztechnik GmbH & Co. KG
Calibration interval
Recommendation
12 months
Recommended accessories
- Rosenberger Test Port Adaptor
- Rosenberger VNA Test cable kit and Microwave Cable Assemblies
For further, more detailed information please visit our homepage
www.rosenberger.com.
While the information has been carefully compiled to the best of our knowledge, nothing is intended as representation or warranty on
our part and no statement herein shall be construed as recommendation to infringe existing patents. In the effort to improve our
products, we reserve the right to make changes judged to be necessary.
RF_35/05.10/6.1
Draft
H. Babinger
Date
25.04.16
Approved
Martin Moder
Date
05.07.18
Rev.
a01
Engineering change number
18-0004
Name
M. Rahberger
Date
05.07.18
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Fax : +49 8684 18-499
Email : info@rosenberger.de
Page