P
RODUCT
O
VERVIEW
The VIPAC Array is a highly flexible system of DC input, power
building-blocks that can be configured with as many as four
user definable outputs on a low profile, coldplate chassis.
VIPAC Array offers the convenience of a prepackaged, chassis
mount solution with the performance and power density of
Vicor’s Maxi, Mini, Micro Series modules, DC-DC converters.
Using Vicor’s VCAD configuration tool, (vicorpower.com/vcad),
designers are able to quickly specify VIPAC Arrays with stan-
dard inputs of 24, 28, 48, 72, 110, 150, 300 or 375 Vdc and
standard outputs from 2 to 48 Vdc at power levels up to 600
Watts per output. A total of 8 standard chassis configurations
offers the user a choice of power and mechanical options to fit
most designs. Short cycle time and rapid delivery make VIPAC
Array a valuable tool for power system prototyping and devel-
opment efforts as well.
For technical information refer to “Design Guide & Applications
Manual for Maxi, Mini, Micro Family DC-DC Converters and
Accessory Modules”
Vicor’s VCAD configuration tool provides expedited part config-
uration, part number, price and delivery information by selecting
standard Maxi, Mini, and Micro modules for use within the VIPAC
Array based on the application requirements. The modules are
chosen based on the input and output requirements and the
closest, but higher power level that is available to that specified.
Specifications for these can be found on their respective
data sheets.
Vicor’s Maxi, Mini, Micro Series
DC-DC Converters
Output Voltages 0.5 – 48 Vdc
50 – 600 W / Output
(1/4 Brick Modules Shown)
Features
Optional current share (single output)
Onboard fusing
Global enable / disable
VIPAC Arrays are ideal for use in distributed and modular
power systems where power density and reliable operation are
critical. A current share option is available on single output mod-
els enabling them to be used in applications requiring either
redundant operation or kilowatts of power. The 300 and 375
Vdc input versions can be coupled to a bulk AC Front-end to
create a modular, scaleable power supply serving a variety of
power architectures from centralized to distributed. VIPAC Arrays
include internal fusing, a global enable / disable function and
connectorized input and output terminations to speed system
installation while a versatile coldplate chassis simplifies thermal
management and mounting.
Choice of Output Termination
LugMate
PlugMate
Standard Output Voltages:
2,3.3,5,8,12,15,24,28,36,48 Vdc
Standard Input
Voltage Ranges
10 – 36 Vdc*
18 – 36 Vdc*
36 – 75 Vdc*
43 – 110 Vdc*
66 – 154 Vdc*
100 – 200 Vdc*
180 – 375 Vdc
250 – 425 Vdc
Low Profile Coldplate
Wide Operating Temperture Range
Up to 95°C Chassis
* Note: 24, 28, 48, 72, 110, and 150 V input VIPAC Arrays
are designed primarily for military COTS and industrial
applications and do not carry safety agency approvals.
2
v
i
c
o
r
p
o
w
e
r
.
c
o
m
/
v
c
a
d
Input / Output Connections
J1
1
11
Input Connector
(View looking into J1)
10
20
Pin#
1-4
5-7
8
9
10
11-13
14-17
18
19
20
Funct.
– Vin
+Vin
NC / PR bus
PE protective earth
Neg. enable
– Vin
+Vin
NC / PR bus
PE protective earth
Pos. enable
J1
3
1
3
1
3
1
VA-J and VA-K configurations only
(300 and 375 Vin single Maxi or single Mini)
Pin#
1-3
4-6
7
8
9
10
11-13
14-16
17
18
19
20
Funct.
– Vin
+Vin
NC
NC / PR bus
PE protective earth
Neg. enable
– Vin
+Vin
NC
NC / PR bus
PE protective earth
Pos. enable
Discrete Output
Parallel Output
Shown with the output(s) of two modules
connected in parallel using factory installed
bus bar.**
Factory installed Micro LugMate
Solder
Pad
Pin #
1
Rd
Ru
SC
Function
– Vout
1
Rd
SC
Ru
3
Trim Down
Secondary Control
Trim Up
+ Vout
To disable output(s) apply +5 Vdc between pins
10 and 20 in the polarity indicated
3
Mating Connector
Vicor part #
Housing
Contacts
Kit
24795
24796
24828
Amp part#
2-794657-0
1-106529-2
Factory installed Mini/Maxi LugMate
Consult design calculator for Rd/Ru trim resis-
tor values located at vicorpower.com
Pin # Conn.
1
1
1
5
J4-1
J4-2
1
5
Function
– Vout
– Vout
– Sense
Mating Conn.
*Removable
Jumper
*
J4-3
–S
P/N 16385
+S
Secondary Control
*Removable
Jumper
P/N
J1
1
5
J4
16385
J4-4
J4-5
5
+ Sense
+ Vout
+ Vout
5
*Removable jumpers in J4 are factory installed for local
sensing. For remote sensing the +Sense pins should be
tied to the same point on the +Out power bus;
the -Sense pins should be tied to the same point the -
Out power bus.
4
v
i
c
o
r
p
o
w
e
r
.
c
o
m
/
v
c
a
d