The “Absolute Maximum Ratings” are those values beyond which
the safety of the device cannot be guaranteed. The device should not be
operated at these limits. The parametric values defined in the Electrical
Characteristics tables are not guaranteed at the absolute maximum rating.
The “Recommended Operating Conditions” table will define the conditions
for actual device operation.
Note 2:
ESD testing conforms to MIL-STD-883, Method 3015.
Commercial Version
DC Electrical Characteristics
(Note 3)
V
EE
= −
4.2V to
−
5.7V, V
CC
=
V
CCA
=
GND, T
C
=
0°C to
+85°C
Symbol
V
OH
V
OL
V
OHC
V
OLC
V
IH
V
IL
I
IL
I
IH
Parameter
Output HIGH Voltage
Output LOW Voltage
Output HIGH Voltage
Output LOW Voltage
Input HIGH Voltage
Input LOW Voltage
Input LOW Current
Input HIGH Current
I
0X
–I
3X
S
0
, S
1
, E
I
EE
Power Supply Current
−75
340
300
−39
mA
Inputs Open
µA
V
IN
=
V
IH
(Max)
−1165
−1830
0.50
Min
−1025
−1830
−1035
−1610
−870
−1475
Typ
−955
−1705
Max
−870
−1620
Units
mV
mV
mV
mV
mV
mV
µA
V
IN
=V
IH
(Max)
or V
IL
(Min)
V
IN
=
V
IH
(Min)
or V
IL
(Max)
Guaranteed HIGH Signal
for All Inputs
Guaranteed LOW Signal
for All Inputs
V
IN
=
V
IL
(Min)
Conditions
Loading with
50Ω to
−2.0V
Loading with
50Ω to
−2.0V
Note 3:
The specified limits represent the “worst case” value for the parameter. Since these values normally occur at the temperature extremes, additional
noise immunity and guardbanding can be achieved by decreasing the allowable system operating ranges. Conditions for testing shown in the tables are cho-
sen to guarantee operation under “worst case” conditions.
DIP AC Electrical Characteristics
V
EE
= −
4.2V to
−
5.7V, V
CC
=
V
CCA
=
GND
Symbol
t
PLH
t
PHL
t
PLH
t
PHL
t
PLH
t
PHL
t
TLH
t
THL
Parameter
Propagation Delay
I
0x
–I
3x
to Output
Propagation Delay
S
0
, S
1
to Output
Propagation Delay
E to Output
Transition Time
20% to 80%, 80% to 20%
T
C
=
0°C
Min
0.45
0.90
0.65
0.35
Max
1.50
2.40
2.30
1.20
T
C
= +25°C
Min
0.45
0.90
0.65
0.35
Max
1.50
2.40
2.30
1.20
T
C
= +85°C
Min
0.45
1.00
0.75
0.35
Max
1.60
2.60
2.40
1.20
Units
ns
ns
ns
ns
Figures 1, 2
Figures 1, 2
(Note 4)
Conditions
Note 4:
The propagation delay specified is for single output switching. Delays may vary up to 300 ps with multiple outputs switching.
3
www.fairchildsemi.com
100371
Commercial Version
(Continued)
SOIC and PLCC AC Electrical Characteristics
V
EE
= −
4.2V to
−
5.7V, V
CC
=
V
CCA
=
GND
Symbol
t
PLH
t
PHL
t
PLH
t
PHL
t
PLH
t
PHL
t
TLH
t
THL
t
OSHL
Parameter
Propagation Delay
I
0x
–I
3x
to Output
Propagation Delay
S
0
, S
1
to Output
Propagation Delay
E to Output
Transition Time
20% to 80%, 80% to 20%
Maximum Skew Common Edge
Output-to-Output Variation
Data to Output Path
t
OSLH
Maximum Skew Common Edge
Output-to-Output Variation
Data to Output Path
t
OST
Maximum Skew Opposite Edge
Output-to-Output Variation
Data to Output Path
t
PS
Maximum Skew
Pin (Signal) Transition Variation
Data to Output Path
Note 5:
The propagation delay specified is for single output switching. Delays may vary up to 300 ps with multiple outputs switching.
Note 6:
Output-to-Output Skew is defined as the absolute value of the difference between the actual propagation delay for any outputs within the same pack-
aged device. The specifications apply to any outputs switching in the same direction either HIGH-to-LOW (t
OSHL
), or LOW-to-HIGH (t
OSLH
), or in opposite
directions both HL and LH (t
OST
). Parameters t
OST
and t
PS
guaranteed by design.
T
C
=
0°C
Min
0.45
0.90
0.65
0.35
Max
1.30
2.20
2.10
1.10
T
C
= +25°C
Min
0.45
0.90
0.65
0.35
Max
1.30
2.20
2.10
1.10
T
C
= +85°C
Min
0.45
1.00
0.75
0.35
Max
1.40
2.40
2.20
1.10
Units
Conditions
ns
ns
ns
ns
Figures 1, 2
PLCC only
Figures 1, 2
(Note 5)
400
400
400
ps
(Note 6)
PLCC only
490
490
490
ps
(Note 6)
PLCC only
490
490
490
ps
(Note 6)
PLCC only
430
430
430
ps
(Note 6)
www.fairchildsemi.com
4
100371
Industrial Version
PLCC DC Electrical Characteristics
(Note 7)
V
EE
= −
4.2V to
−
5.7V, V
CC
=
V
CCA
=
GND, T
C
= −40°C
to
+85°C
T
C
= −40°C
Symbol
Parameter
Min
Max
V
OH
V
OL
V
OHC
V
OLC
V
IH
V
IL
I
IL
I
IH
Output HIGH Voltage
Output LOW Voltage
Output HIGH Voltage
Output LOW Voltage
Input HIGH Voltage
Input LOW Voltage
Input LOW Current
Input HIGH Current
I
0X
–I
3X
S
0
, S
1
, E
I
EE
Power Supply Current
−75
340
300
−35
−75
340
300
−39
mA
Inputs Open
µA
V
IN
=
V
IH
(Max)
−1170
−1830
0.50
−1085
−1830
−1095
−1565
−870
−1480
−1165
−1830
0.50
−870
−1575
T
C
=
0°C to
+85°C
Min
−1025
−1830
−1035
−1610
−870
−1475
Max
−870
−1620
Units
mV
mV
mV
mV
mV
mV
µA
Conditions
V
IN
=V
IH
(Max)
or V
IL
(Min)
V
IN
=
V
IH
(Min)
or V
IL
(Max)
Guaranteed HIGH Signal
for All Inputs
Guaranteed LOW Signal
for All Inputs
V
IN
=
V
IL
(Min)
Loading with
50Ω to
−2.0V
Loading with
50Ω to
−2.0V
Note 7:
The specified limits represent the “worst case” value for the parameter. Since these values normally occur at the temperature extremes, additional
noise immunity and guardbanding can be achieved by decreasing the allowable system operating ranges. Conditions for testing shown in the tables are cho-
sen to guarantee operation under “worst case” conditions.
PLCC AC Electrical Characteristics
V
EE
= −
4.2V to
−
5.7V, V
CC
=
V
CCA
=
GND
Symbol
t
PLH
t
PHL
t
PLH
t
PHL
t
PLH
t
PHL
t
TLH
t
THL
Parameter
Propagation Delay
I
0x
–I
3x
to Output
Propagation Delay
S
0
, S
1
to Output
Propagation Delay
E to Output
Transition Time
20% to 80%, 80% to 20%
T
C
= −40°C
Min
0.40
0.70
0.65
0.20
Max
1.30
2.20
2.10
1.60
T
C
= +25°C
Min
0.45
0.90
0.65
0.35
Max
1.30
2.20
2.10
1.10
T
C
= +85°C
Min
0.45
1.00
0.75
0.35
Max
1.40
2.40
2.20
1.10
Units
ns
ns
ns
ns
Figures 1, 2
Figures 1, 2
(Note 8)
Conditions
Note 8:
The propagation delay specified is for single output switching. Delays may vary up to 300 ps with multiple outputs switching.