Contact insert - HC-BB10-I-CT-F - 1584703
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
HEAVYCON socket insert, series: BB10, 10-pos., crimp connection, with plastic coding profile, can be coded
Product Features
For fast coding with plastic profile (Order No. 1410916, type CP-HC-S)
Key commercial data
Packing unit
Custom tariff number
Country of origin
1 pc
85366990
China
Technical data
General
Connection method
Pollution degree
Surge voltage category
Number of positions
Insertion/withdrawal cycles
Type
Connection in acc. with standard
Conductor cross section
Connection cross section AWG
Stripping length of the individual wire
Assembly instructions
Connection
Crimp connection
3
III
10+PE
≥ 500
B6
IEC / EN
0.5 mm² ... 4 mm²
20 ... 12
7.5 mm
- Housing heights of h ≥ 72 mm are recommended when there is a high
number of wires.
Connectors may only be inserted when there is no load/the power is
switched off. Contact release by means of CK2,5-EWZ (Order No.
1662722)
Ambient conditions
05/13/2015 Page 1 / 4
https://www.phoenixcontact.com/us/products/1584703
Contact insert - HC-BB10-I-CT-F - 1584703
Technical data
Ambient conditions
Ambient temperature (operation)
-40 °C ... 125 °C (including heating up of contacts)
Material data
Inflammability class according to UL 94
Contact material
Contact surface material
Contact carrier material
V0
Copper alloy
Ag (alternatively Au)
PC
Electrical characteristics
Rated voltage (III/3)
Rated surge voltage
Rated current
500 V
6 kV
16 A
Classifications
eCl@ss
eCl@ss 4.0
eCl@ss 4.1
eCl@ss 5.0
eCl@ss 5.1
eCl@ss 6.0
eCl@ss 7.0
eCl@ss 8.0
272607xx
27260701
27143424
27143424
27143424
27440209
27440205
ETIM
ETIM 4.0
ETIM 5.0
EC000438
EC000438
UNSPSC
UNSPSC 6.01
UNSPSC 7.0901
UNSPSC 11
UNSPSC 12.01
UNSPSC 13.2
30211923
39121522
39121522
39121522
39121522
Approvals
Approvals
05/13/2015 Page 2 / 4
https://www.phoenixcontact.com/us/products/1584703
Contact insert - HC-BB10-I-CT-F - 1584703
Approvals
Approvals
UL Recognized / EAC / CSA
Ex Approvals
Approvals submitted
Approval details
UL Recognized
mm²/AWG/kcmil
Nominal current IN
Nominal voltage UN
12
20 A
600 V
EAC
CSA
mm²/AWG/kcmil
Nominal current IN
Nominal voltage UN
12
18 A
600 V
Drawings
05/13/2015 Page 3 / 4
https://www.phoenixcontact.com/us/products/1584703
Contact insert - HC-BB10-I-CT-F - 1584703
Diagram
I [A]
35
30
25
20
15
10
5
0
0
= HC-BB 10
= HC-BB 18
= HC-BB 32
= HC-BB 46
Dimensional drawing
4 mm
²
51
44
34
27
20
40
60
80
100
120
T [°C]
Female insert
Derating diagram (conductor cross section: 4.0 mm²)
Dimensional drawing
44
36
8
9
10
7
6
Schematic diagram
4
1
2
1
2
3
4
6
8
9
5
3
5
7
10
27
Ø3,4
20
35
Connector pin assignment: Left pin - right socket
Mounting cutout when used without housing
Phoenix Contact 2015 © - all rights reserved
http://www.phoenixcontact.com
05/13/2015 Page 4 / 4
36,2