Plug-in miniature solid-state relay, power solid-state relay, 1 N/O contact, input: 5 V DC, output: 24 - 253 V
AC/0.75 A
Why buy this product
Vibration and shock resistant
RT III-proof (wash-proof)
Wear-free and durable
Can be soldered on PCB
Key Commercial Data
Packing unit
Minimum order quantity
GTIN
GTIN
4046356418973
10 pc
10 pc
Technical data
Dimensions
Width
Height
Depth
5 mm
28 mm
15 mm
Ambient conditions
Ambient temperature (operation)
Ambient temperature (storage/transport)
-20 °C ... 60 °C
-25 °C ... 75 °C
Input data
Nominal input voltage U
N
Input voltage range in reference to U
N
Input voltage range
5 V DC
0.8 ... 1.2
4 V DC ... 6 V DC
09/30/2018 Page 1 / 4
https://www.phoenixcontact.com/pi/products/2982139
Miniature solid-state relay - OPT- 5DC/230AC/ 1 - 2982139
Technical data
Input data
Switching threshold "0" signal, voltage
Switching threshold "1" signal voltage
Typical input current at U
N
Typical response time
Typical turn-off time
Transmission frequency
≤ 1.4 V
≥3V
7 mA
10 ms
10 ms
10 Hz
Output data
Output voltage range
Limiting continuous current
Maximum inrush current
Min. load current
Leakage current
Max. load value
Voltage drop at max. limiting continuous current
Output circuit
Type of protection
Protective circuit/component
24 V AC ... 253 V AC
0.75 A (see derating curve)
30 A (10 ms)
10 mA
< 1 mA (in off state)
4.5 A s
<1V
2-conductor floating, zero voltage switch
RCV circuit
RCV circuit
2
General
Mounting position
Assembly instructions
Operating mode
Degree of protection
Designation
Standards/regulations
Degree of pollution
Overvoltage category
any
In rows with zero spacing
100% operating factor
RT III (wash-proof)
Standards/regulations
IEC 60664
EN 50178
2
III
Standards and Regulations
Designation
Standards/regulations
Rated insulation voltage
Rated surge voltage
Degree of pollution
Overvoltage category
Standards/regulations
IEC 60664
EN 50178
260 V AC
4 kV (basic insulation)
2
III
Environmental Product Compliance
China RoHS
Environmentally Friendly Use Period = 50
09/30/2018 Page 2 / 4
https://www.phoenixcontact.com/pi/products/2982139
Miniature solid-state relay - OPT- 5DC/230AC/ 1 - 2982139
Technical data
Environmental Product Compliance
For details about hazardous substances go to tab “Downloads”,
Category “Manufacturer's declaration”
Drawings
Drilling diagram
Dimensional drawing
28
1
1,3
1,9
5
1,2
a = pitch division 1.25 mm and 1.27 mm
Circuit diagram
A2
A1
13+
3,5
14
Approvals
Approvals
Approvals
UL Recognized / cUL Recognized / EAC / cULus Recognized
Ex Approvals
Approval details
UL Recognized
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
15
FILE E 195083
09/30/2018 Page 3 / 4
https://www.phoenixcontact.com/pi/products/2982139
Miniature solid-state relay - OPT- 5DC/230AC/ 1 - 2982139
Approvals
cUL Recognized
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
FILE E 195083
EAC
RU C-
DE.A*30.B.01082
cULus Recognized
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
Phoenix Contact 2018 © - all rights reserved
http://www.phoenixcontact.com
PHOENIX CONTACT GmbH & Co. KG
Flachsmarktstr. 8
32825 Blomberg
Germany
Tel. +49 5235 300
Fax +49 5235 3 41200
http://www.phoenixcontact.com
09/30/2018 Page 4 / 4