74HC2G04-Q100;
74HCT2G04-Q100
Dual inverter
Rev. 2 — 11 June 2018
Product data sheet
1
General description
The 74HC2G04-Q100; 74HCT2G04-Q100 is a dual inverter. Inputs include clamp diodes
that enable the use of current limiting resistors to interface inputs to voltages in excess of
V
CC
.
This product has been qualified to the Automotive Electronics Council (AEC) standard
Q100 (Grade 1) and is suitable for use in automotive applications.
2
Features and benefits
•
Automotive product qualification in accordance with AEC-Q100 (Grade 1)
–
Specified from -40 °C to +85 °C and from -40 °C to +125 °C
•
Wide supply voltage range from 2.0 V to 6.0 V
•
Input levels:
–
For 74HC2G04-Q100: CMOS level
–
For 74HCT2G04-Q100: TTL level
•
Complies with JEDEC standard no. 7A
•
High noise immunity
•
ESD protection:
–
MIL-STD-883, method 3015 exceeds 2000 V
–
HBM JESD22-A114F exceeds 2000 V
–
MM JESD22-A115-A exceeds 200 V (C = 200 pF, R = 0 Ω)
•
Low power dissipation
•
Balanced propagation delays
•
Multiple package options
3
Ordering information
Package
Temperature range
Name
SC-88
SC-74
Description
plastic surface-mounted package; 6 leads
plastic surface-mounted package (TSOP6);
6 leads
Version
SOT363
SOT457
-40 °C to +125 °C
-40 °C to +125 °C
Table 1. Ordering information
Type number
74HC2G04GW-Q100
74HCT2G04GW-Q100
74HC2G04GV-Q100
74HCT2G04GV-Q100
Nexperia
74HC2G04-Q100; 74HCT2G04-Q100
Dual inverter
4
Marking
Marking code
H4
T4
H04
T04
Table 2. Marking
Type number
74HC2G04GW-Q100
74HCT2G04GW-Q100
74HC2G04GV-Q100
74HCT2G04GV-Q100
5
Functional diagram
1
3
1A
2A
1Y
2Y
mnb079
6
4
1
1
6
3
1
mnb080
4
A
Y
mna110
Figure 1. Logic symbol
Figure 2. IEC logic symbol
Figure 3. Logic diagram (one gate)
6
Pinning information
6.1 Pinning
74HC2G04-Q100
74HCT2G04-Q100
1A 1
GND 2
2A 3
6 1Y
5 V
CC
4 2Y
aaa-010001
Figure 4. Pin configuration SOT363 and SOT457
6.2 Pin description
Table 3. Pin description
Symbol
1A
GND
2A
2Y
V
CC
1Y
74HC_HCT2G04_Q100
Pin
1
2
3
4
5
6
All information provided in this document is subject to legal disclaimers.
Description
data input
ground (0 V)
data input
data output
supply voltage
data output
© Nexperia B.V. 2018. All rights reserved.
Product data sheet
Rev. 2 — 11 June 2018
2 / 15
Nexperia
74HC2G04-Q100; 74HCT2G04-Q100
Dual inverter
7
Functional description
Table 4. Function table
H = HIGH voltage level; L = LOW voltage level.
Input
nA
L
H
Output
nY
H
L
8
Limiting values
Table 5. Limiting values
In accordance with the Absolute Maximum Rating System (IEC 60134). Voltages are referenced to GND (ground = 0 V).
Symbol Parameter
V
CC
I
IK
I
OK
I
O
I
CC
I
GND
T
stg
P
tot
supply voltage
input clamping current
output clamping current
output current
supply current
ground current
storage temperature
total power dissipation
[2]
Conditions
V
I
< -0.5 V or V
I
> V
CC
+ 0.5 V
V
O
< -0.5 V or V
O
> V
CC
+ 0.5 V
V
O
= -0.5 V to V
CC
+ 0.5 V
[1]
[1]
[1]
[1]
[1]
Min
-0.5
-
-
-
-
-
-65
-
Max
+7.0
±20
±20
±25
+50
-50
+150
250
Unit
V
mA
mA
mA
mA
mA
°C
mW
[1] The minimum input and output voltage ratings may be exceeded if the input and output current ratings are observed.
[2] For SC-88 and SC-74 packages: above 87.5 °C the value of P
tot
derates linearly with 4.0 mW/K.
9
Recommended operating conditions
Table 6. Recommended operating conditions
Voltages are referenced to GND (ground = 0 V).
Symbol Parameter
V
CC
V
I
V
O
T
amb
Δt/ΔV
supply voltage
input voltage
output voltage
ambient temperature
input transition rise and
fall rate
V
CC
= 2.0 V
V
CC
= 4.5 V
V
CC
= 6.0 V
Conditions
74HC2G04-Q100
Min
2.0
0
0
-40
-
-
-
Typ
5.0
-
-
+25
-
-
-
Max
6.0
V
CC
V
CC
+125
625
139
83
74HCT2G04-Q100
Min
4.5
0
0
-40
-
-
-
Typ
5.0
-
-
+25
-
-
-
Max
5.5
V
CC
V
CC
+125
-
139
-
V
V
V
°C
ns/V
ns/V
ns/V
Unit
74HC_HCT2G04_Q100
All information provided in this document is subject to legal disclaimers.
© Nexperia B.V. 2018. All rights reserved.
Product data sheet
Rev. 2 — 11 June 2018
3 / 15
Nexperia
74HC2G04-Q100; 74HCT2G04-Q100
Dual inverter
10 Static characteristics
Table 7. Static characteristics for 74HC2G04-Q100
At recommended operating conditions; voltages are referenced to GND (ground = 0 V).
Symbol Parameter
T
amb
= 25 °C
V
IH
HIGH-level input voltage V
CC
= 2.0 V
V
CC
= 4.5 V
V
CC
= 6.0 V
V
IL
LOW-level input voltage
V
CC
= 2.0 V
V
CC
= 4.5 V
V
CC
= 6.0 V
V
OH
HIGH-level output
voltage
V
I
= V
IH
or V
IL
I
O
= -20 μA; V
CC
= 2.0 V
I
O
= -20 μA; V
CC
= 4.5 V
I
O
= -20 μA; V
CC
= 6.0 V
I
O
= -4.0 mA; V
CC
= 4.5 V
I
O
= -5.2 mA; V
CC
= 6.0 V
V
OL
LOW-level output
voltage
V
I
= V
IH
or V
IL
I
O
= 20 μA; V
CC
= 2.0 V
I
O
= 20 μA; V
CC
= 4.5 V
I
O
= 20 μA; V
CC
= 6.0 V
I
O
= 4.0 mA; V
CC
= 4.5 V
I
O
= 5.2 mA; V
CC
= 6.0 V
I
l
I
CC
C
I
input leakage current
supply current
input capacitance
V
I
= GND or V
CC
; V
CC
= 6.0 V
V
I
= GND or V
CC
; I
O
= 0 A;
V
CC
= 6.0 V
-
-
-
-
-
-
-
-
0
0
0
0.15
0.16
-
-
1.5
0.1
0.1
0.1
0.26
0.26
±0.1
1.0
-
V
V
V
V
V
μA
μA
pF
1.9
4.4
5.9
4.18
5.68
2.0
4.5
6.0
4.32
5.81
-
-
-
-
-
V
V
V
V
V
1.5
3.15
4.2
-
-
-
1.2
2.4
3.2
0.8
2.1
2.8
-
-
-
0.5
1.35
1.8
V
V
V
V
V
V
Conditions
Min
Typ
Max
Unit
74HC_HCT2G04_Q100
All information provided in this document is subject to legal disclaimers.
© Nexperia B.V. 2018. All rights reserved.
Product data sheet
Rev. 2 — 11 June 2018
4 / 15
Nexperia
74HC2G04-Q100; 74HCT2G04-Q100
Dual inverter
Symbol Parameter
T
amb
= -40 °C to +85 °C
V
IH
Conditions
Min
1.5
3.15
4.2
-
-
-
1.9
4.4
5.9
4.13
5.63
-
-
-
-
-
-
-
Typ
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Max
-
-
-
0.5
1.35
1.8
-
-
-
-
-
0.1
0.1
0.1
0.33
0.33
±1.0
10.0
Unit
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
μA
μA
HIGH-level input voltage V
CC
= 2.0 V
V
CC
= 4.5 V
V
CC
= 6.0 V
V
IL
LOW-level input voltage
V
CC
= 2.0 V
V
CC
= 4.5 V
V
CC
= 6.0 V
V
OH
HIGH-level output
voltage
V
I
= V
IH
or V
IL
I
O
= -20 μA; V
CC
= 2.0 V
I
O
= -20 μA; V
CC
= 4.5 V
I
O
= -20 μA; V
CC
= 6.0 V
I
O
= -4.0 mA; V
CC
= 4.5 V
I
O
= -5.2 mA; V
CC
= 6.0 V
V
OL
LOW-level output
voltage
V
I
= V
IH
or V
IL
I
O
= 20 μA; V
CC
= 2.0 V
I
O
= 20 μA; V
CC
= 4.5 V
I
O
= 20 μA; V
CC
= 6.0 V
I
O
= 4.0 mA; V
CC
= 4.5 V
I
O
= 5.2 mA; V
CC
= 6.0 V
I
l
I
CC
input leakage current
supply current
V
I
= GND or V
CC
; V
CC
= 6.0 V
V
I
= GND or V
CC
; I
O
= 0 A;
V
CC
= 6.0 V
74HC_HCT2G04_Q100
All information provided in this document is subject to legal disclaimers.
© Nexperia B.V. 2018. All rights reserved.
Product data sheet
Rev. 2 — 11 June 2018
5 / 15