MCR-T-UI(/NC)
MCR-T-UI-E(/NC)
Programmable Temperature Transducers for
Resistance Thermometers and Thermocouples
INTERFACE
Data Sheet
100242_03_en
Description
A universal temperature measuring transducer for
resistance thermometers and thermocouples, with freely
selectable temperature range, is available for the
MCR-T-UI
converters:
– Resistance thermometer: -200...+850°C
– Thermocouples: -200...+2300°C
At the output side, the following analog standard signals can
be used with normal (e. g. 0...10 V) and inverse (e. g.
10...0 V) action:
– 0...20 mA
– 4...20 mA
– 0...10 V
– ±10 V
– 0...5 V
– 1...5 V
– ±5 V
A PNP transistor switching output (100 mA) with two
switching points and eight switching functions provides an
additional monitoring function.
© PHOENIX CONTACT - 06/2007
Versions
–
Standard configuration:
MCR-T-UI(-E)-NC
(Pt 100 according to DIN IEC 60751, with 3-wire
technology of -200...+850°C with 4...20 mA output and
blocked switching output)
Configuration on basis of order:
MCR-T-UI(-E)
Specify the configuration in the order key (see page 2).
Upon delivery the module is configured according to
user requirements and therefore ready to operate.
–
The modules can be parameterized freely using the
configuration software MCR/PI-CONF-WIN.
Make sure you always use the latest documentation.
It can be downloaded from
www.download.phoenixcontact.com.
A conversion table is available on the internet at
www.download.phoenixcontact.com/general/7000_en_00.pdf.
This data sheet is valid for the following products:
MCR-T-UI…
Ordering Data
Temperature Measuring Transducers
Description
Programmable temperature transducers for thermocouples and resistance
thermometers with 2, 3, or 4-wire technology, not configured
Programmable temperature transducers for thermocouples and resistance
thermometers with 2, 3, or 4-wire technology, configured
Programmable temperature transducers for thermocouples and resistance
thermometers with 2, 3, or 4-wire technology, with electrical isolation between
input/output and input/auxiliary power, not configured
Programmable temperature transducers for thermocouples and resistance
thermometers with 2, 3, or 4-wire technology, with electrical isolation between
input/output and input/auxiliary power, configured
1
Type
MCR-T-UI/NC
MCR-T-UI...
1
MCR-T-UI-E/NC
Order No.
2814100
2814090
2814126
Pcs./Pck.
1
1
1
MCR-T-UI-E...
1
2814113
1
See "Order key for MCR-T-UI and MCR-T-UI-E"
Accessories
Description
PI/MCR configuration software, for programming the PI/Ex-RTD...,
PI/Ex-THC..., MCR-T..., MCR-PSP..., MCR-f... and MCR-s... modules
Software adapter cable (stereo jack connector/D-SUB 25-pos.),
1.2 m, for programming MCR-T-UI... modules
Type
MCR/PI-CONF-WIN
MCR-TTL-RS232-E
Order No.
2814799
2814388
Pcs./Pck.
1
1
Order
Key
for MCR-T-UI and MCR-T-UI-E
The standard configuration will be supplied if customer order details are incorrect or not provided.
Type of
sensor
Standard configuration:
2814090
/
2814090
=
MCR-T-UI
2814100
=
MCR-T-UI-NC
2814113
=
MCR-T-UI-E
2814126
=
MCR-T-UI-E-NC
Characteristic
curve
/
D
D
=
DIN
S
=
SAMA
0
=
for thermocouple,
resistor,
potentiometer,
voltage, Ni 1000
(Landis & Gyr),
Cu 10, KTY 81-110,
Cu 50, Cu 53
Connection
technology
/
2
3
4
0
=
=
=
=
Measuring range
PT100
3
2-wire
3-wire
3-wire
for thermocouple,
resistor,
potentiometer,
voltage
/
-200,0
Initial value
at 0 mA
(e. g. -200.0°C)
/
+850,0
End value
at 20 mA
(e. g. +850.0°C)
/
see tables on
page 3 under
"Type of sensor" or
"Order reference"
Unit of
measurement
C
C
F
V
O
P
=
=
=
=
=
°C
°F
mV
Ω
%
Output
/
OUT02
OUT01
=
OUT02
=
OUT03
=
OUT05
=
OUT13
=
OUT14
=
0...20 mA
4...20 mA
0...10 V
0...5 V
-5...+5 V
-10...+10 V
/
Output
characteristic
curve
N
N
=
normal
I
=
inverse
Factory calibration
certificate
/
NONE
NONE
=
without factory
calibration certificate
YES
=
with factory calibration
certificate (a fee is
charged)
YESPLUS
=
with factory calibration
certificate WKZ ... with 5
measuring points
(a fee is charged)
100242_03_en
PHOENIX CONTACT
2
MCR-T-UI…
Resistance thermometer
1
Type of
sensor
2
Pt ...
Ni ...
Ni 1000
Cu 10
Cu 50
Cu 53
KTY 81 (=
KTY 81-110)
KTY 84 (=
KTY 84-130)
1
Thermocouples
1
Smallest
measuring
range span
0.4 K
0.4 K
0.4 K
0.4 K
0.4 K
0.4 K
0.4 K
–
Type of
sensor
2
U
1
T
1
Measuring range
Standard
Material
Measuring range
Smallest
measuring
range span
>1K
>1K
>1K
>1K
>1K
>1K
>1K
>4K
>4K
> 10 K
>4K
>4K
>1K
-200...+850°C
-60...+180°C
-50...+160°C
-70...+500°C
-50...+200°C
-50...+180°C
-55...+150°C
-40...+300°C
DIN/SAMA
DIN/SAMA
Landis & Gyr
SAMA
–
–
Philips
–
Cu-CuNi
Cu-CuNi
Fe-CuNi
Fe-CuNi
NiCr-CuNi
NiCr-Ni
NiCrSi-NiSi
Pt10Rh-Pt
Pt13Rh-Pt
Pt30Rh-Pt6Rh
–
–
–
-200...+600°C
-200...+400°C
-200...+900°C
-210...+1200°C
-226...+1000°C
-200...+1372°C
-200...+1300°C
-50...+1768°C
-50...+1768°C
500...+1820°C
-18...+2316°C
-18...+2316°C
-200...+800°C
L
1
J
1
E
1
1
K
S
N
1
1
R
1
B
1
C
W
HK
1
2
Temperature ranges in accordance with IEC 60751/EN 60751 or
DIN 43760 and
SAMA RC 21-4-1966 in 2, 3 or 4-wire technology
Other types and characteristic curves on request.
2
Thermocouples in acc. with IEC 60584/EN 60584
Other types and characteristic curves on request.
Resistors, potentiometers, mV-voltages
Input
Measuring range
Order reference
Smallest
measuring
range span
2
Ω
0.2%
2 mV
Resistor
Potentiometer
(max. 8 kΩ)
Voltage
0...8 kΩ
(2-wire technology)
0...100%
(3-wire technology)
-20 mV ... +2400 mV
RES
POT
VOL
Order Examples for MCR-T-UI(-E) With Different Input Versions
Resistance thermometer
2814113 / PT100 /
Thermocouple
2814113 /
J
Voltage
2814113
D
/
3
/
-200,0
/ +850,0 /
C
/ OUT02 /
N
/
NONE
Configuration for 3-wire Pt 100 sensor -200.0...+850.0°C with output characteristic curve 4...20 mA, without factory calibration certificate
/
0
/
0
/
-346
/
+2192
/
F
/ OUT02 /
N
/
NONE
Configuration for type J thermocouple of -346...+2192°F with 4...20 mA output characteristic curve, without factory calibration certificate
/
VOL
/
0
/
0
/
-10
/
1200
/
V
/ OUT03 /
I
/
YES
Configuration for voltage input of -10...+1200 mV with 10...0 V output characteristic curve, with factory calibration certificate
Resistor (2-wire technology)
2814113 /
RES
/
0
/
0
/
0
/
7500
/
O
/ OUT05 /
N
/
NONE
Configuration for connecting a resistor, which varies between 0
Ω
and 7.5 kΩ, with 0...5 V output signal, without factory calibration certificate
Potentiometer (3-wire technology)
2814113 /
POT
/
0
/
0
/
10
/
90
/
P
/ OUT02 /
N
/
NONE
Configuration for connecting a 3-wire potentiometer, where 10% ... 90% of the range is used, with 4...20 mA output signal, without factory calibration
certificate
100242_03_en
PHOENIX CONTACT
3
MCR-T-UI…
Technical Data
Input
Resistance thermometer
in 2, 3 and 4-wire technology
in accordance with IEC 60751/EN 60751 or DIN 43760 and SAMA RC 21-4-
1966
B, E, J, K, N, R, S, T, L, U, C, W, HK
in acc. with IEC 60584/EN 60584
≤
8 kΩ
≤
8 kΩ
-20 mV... +2400 mV
250
μA
Transient protection, surge protection 30 V DC
Thermocouples
Resistors
Potentiometers
Linear mV signals
Supply current (resistance thermometer)
Input protection
Output
Output signal
Max. output signal
Load
Ripple
Output signal on open circuit (adjustable)
Overrange/underrange (adjustable)
Resolution
Output protection
U
OUT
0 V ... 5 V / 0 V ... 10 V
±5 V / ±10 V
±12 V
≥
10 kΩ
≤
20 mV
PP
-12 V ... +12 V
-12 V ... +12 V
3 mV
Transient protection
I
OUT
0 mA ... 20 mA
4 mA ... 20 mA
24 mA
≤
500
Ω
≤
20 mV
PP
0 mA ... 24 mA
0 mA ... 24 mA
6
μA
Transient protection
Switching Output
Output description
Load capability
Transistor output, PNP
100 mA
The switching output switches the supply voltage and is not short-circuit-proof.
General Data
Supply voltage
Current consumption at 24 V DC
Maximum
Typical
Transmission error
of end value
at the output
Cold junction error
Maximum
Typical
Temperature coefficient
Maximum
Typical
Test voltage
Input/output
Input/supply
Ambient temperature range
Dimensions (W x H x D)
Conductor cross section
Stripping length
Housing version
1 kV, 50 Hz, 1 minute
1 kV, 50 Hz, 1 minute
-20 °C ... +65°C
17.5 mm x 99 mm x 114.5 mm
0.2 mm
2
... 2.5 mm
2
8 mm
Polyamide PA not reinforced, color green
0.01%/K
0.005%/K
≤
3K
1.5 K
< 0,1%
±6 mV/12
μA
< 60 mA
40 mA
18 V DC ... 30 V DC
100242_03_en
PHOENIX CONTACT
4
MCR-T-UI…
Approvals
CE
GL
UL/CUL Recognized
MCR-T-UI/NC
MCR-T-UI...
MCR-T-UI-E/NC
MCR-T-UI-E...
UL/CUL Listed
MCR-T-UI-E/NC
MCR-T-UI-E...
PROCESS CONTROL EQUIPMENT FOR HAZARDOUS
LOCATIONS
LISTED 31ZN
Class I Div 2 Groups A, B, C, D
A) This equipment is suitable for use in Class I, Division 2, Groups
A, B, C and D or non-hazardous locations only.
B) Warning - explosion hazard - substitution of components may
impair suitability for Class 1, Division 2.
C) Warning - explosion hazard - do not disconnect equipment
unless power has been switched off or the area is known to be
non-hazardous.
c
F
u
U
Conformance With EMC Directive 89/336/EEC and Low Voltage Directive 73/23/EEC
Noise Immunity Test According to EN 61000-6-2
Discharge of static electricity (ESD)
Air discharge
Contact discharge
Electromagnetic HF field
Amplitude modulation 10 V/m
Pulse modulation
Fast transients (burst)
Input/output/supply
Surge current load (surge)
Input/output
Supply
Conducted interference
Input/output/supply
EN 61000-4-6
Criterion A
EN 61000-4-5
Criterion B
1 kV/2 kV/42
Ω
0.5 kV/2
Ω
10 V
EN 61000-4-4
Criterion B
2 kV/5 Hz
EN 61000-4-3
Criterion A
10 V/m
10 V/m
EN 61000-4-2
Criterion B
8 kV
6 kV
Noise Emission Test According to EN 61000-6-4
Noise emission, housing
EN 55011
Class A
100242_03_en
PHOENIX CONTACT
5