Technical Data Sheet - Draft
Adaptor
N Plug – NEX10 Plug
53S189-S00N1
Dieses Dokument ist urheberrechtlich geschützt
●
This document is protected by copyright
●
Rosenberger Hochfrequenztechnik GmbH & Co. KG
All dimensions are in mm; tolerances according to ISO 2768 m-H
Interface
According to
NEX10 side:
N side:
tbd
IEC 61169-16, MIL-PRF-39012, CECC 22210
Material and Plating
Connector parts
Center contact
Outer contact
Outer contact
Body
Dielectric
Gasket
N side:
NEX10 side:
Material
Brass
Brass
Spring bronze
Brass
PTFE
Silicone
Plating
Silver, 3-6 µm
White bronze(e.g. Optalloy®)
Silver, 3-6 µm
White bronze(e.g. Optalloy®)
RF_35/05.10/6.0
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Tel. : +49 8684 18-0
mail : info@rosenberger.de
Page
1/2
Technical Data Sheet - Draft
Adaptor
N Plug – NEX10 Plug
Electrical Data
Impedance
Frequency
Return loss
50
Ω
DC to 11 GHz
≥
36 dB @ DC to 4 GHz
≥
28 dB @ 4 GHz to 6 GHz
≥
26 dB @ 6 GHz to 10 GHz
≤
0.05 x
53S189-S00N1
Dieses Dokument ist urheberrechtlich geschützt
●
This document is protected by copyright
●
Rosenberger Hochfrequenztechnik GmbH & Co. KG
Insertion loss
Insulation resistance
Center contact resistance
Outer contact resistance
Test voltage
RF-leakage
Power handling
Intermodulation
(3
rd
order)
f [GHz]
dB
≥
5 GΩ
≤
2.0 mΩ, NEX10 side
≤
1.0 mΩ, N side
≤
1.0 mΩ, NEX10 side
≤
0.25 mΩ, N side
500 V rms
≥
110 dB @ DC to 6 GHz
100 W @ 2.0 GHz and 85°C ambient temperature
≥
155 dBc (2 x 43 dBm) @ 0.4 – 6.0 GHz
Mechanical Data
Mating cycles
Recommended torque
NEX10 side
≥
100
1.5 Nm
N side
≥
500
0.7 Nm to 1.1 Nm
Environmental Data
Temperature range
Thermal shock
Vibration
Shock
Degree of protection (mated pair)
RoHS
-55 °C to +125 °C operating temperature
IEC 61169-1 9.4.4
IEC 61169-1 9.3.3 and IEC 60068-2-64
IEC 61169-1 9.3.14
IEC 60529, IP68 24h / 1m
compliant
Tooling
N/A
Suitable Cables
N/A
Weight
Weight
39.85g/pcs
While the information has been carefully compiled to the best of our knowledge, nothing is intended as representation or warranty on
our part and no statement herein shall be construed as recommendation to infringe existing patents. In the effort to improve our
products, we reserve the right to make changes judged to be necessary.
Draft
F. Fraunhofer
Date
21.04.17
Approved
F. Fraunhofer
Date
18.10.2017
Rev.
300
Engineering change number
17-v097
Name
Tobi Stadler
Date
18.10.2017
RF_35/05.10/6.0
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Email : info@rosenberger.de
Page
2/2