Output voltage and constant current level programmable
Active current sharing up to 9600W (5+1)
Built-in remote ON-OFF control / remote sense /
auxiliary power
/
DC OK signal / OTP alarm signal
Protections: Short circuit / Overload / Over voltage
/ Over temperature
Optional PMBus or CANBus protocol
5 years warranty
■
Applications
Factory control or automation apparatus
Test and measurement instrument
Laser related machine
Aging facility
Digital broadcasting
Constant current source
Redundant system
■
Description
RSP-1600 is a 1.6KW single output enclosed type AC/DC power supply with a 1U low profile and a high
power density up to 25W/inch
3
. This series operates for 90~264VAC input voltage and offers the models
with the DC output mostly demanded from the industry. Each model is cooled by the thermostatically
controlled fan. Moreover, RSP-1600 provides vast design flexibility by equipping various built-in functions
such as the output programming, active current sharing, remote ON-OFF control, auxiliary power, etc.
■
Model Encoding / Order Information
RSP - 1600 - 48
Communication protocol option
Output voltage (12V/24V/27V/36V/48V)
Output wattage
Series name
Type
Blank
PM
CAN
Communication Protocol
None
PMBus protocol
CANBus protocol
Note
In Stock
By request
By request
File Name:RSP-1600-SPEC 2018-01-15
1600W Power Supply with Single Output
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
INPUT
RSP-1600-12
12V
125A
0 ~ 125A
1500W
11.5 ~ 15V
±0.5%
±0.5%
RSP-1600-24
24V
67A
0 ~ 67A
1608W
200mVp-p
23.5 ~ 30V
±1.0%
±0.5%
±0.5%
RSP-1600-27
27V
59A
0 ~ 59A
1593W
200mVp-p
26.5 ~ 33.5V
±1.0%
±0.5%
±0.5%
RSP-1600
RSP-1600-36
36V
44.5A
0 ~ 44.5A
1602W
250mVp-p
35.5 ~ 45V
±1.0%
±0.5%
±0.5%
48V
33.5A
0 ~ 33.5A
1608W
300mVp-p
series
RSP-1600-48
RIPPLE & NOISE (max.)
Note.2
150mVp-p
VOLTAGE TOLERANCE
Note.4
±1.0%
47.5 ~ 58.8V
±1.0%
±0.5%
±0.5%
1500ms, 60ms/230VAC at full load
16ms / 230VAC at 75% load
Note.5
90 ~ 264VAC
10ms / 230VAC at full load
127 ~ 370VDC
47 ~ 63Hz
0.97/230VAC at full load
92%
8.5A/230VAC
92%
93%
89%
91.5%
AC CURRENT (Typ.)
Note.5
14A/115VAC 8A/230VAC 15A/115VAC
COLD START 35A/230VAC
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
<2mA / 230VAC
105 ~ 115% rated output power
Protection type : Constant current limiting, unit will shut down o/p voltage after 5 sec. re-power on to recover
15.75 ~ 18.75V
31.5 ~ 37.5V
35.2 ~ 41.9V
47.2 ~ 56.3V
63 ~ 75V
Protection type : Shut down o/p voltage, re-power on to recover
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
PROTECTION
OVER VOLTAGE
OVER TEMPERATURE
Adjustment of output voltage is allowable to 40 ~ 125% of nominal output voltage (60 ~ 125% for 12V).
OUTPUT VOLTAGE
PROGRAMMABLE(PV)
Note 6
Please refer to the Function Manual.
Adjustment of constant current level is allowable to 20 ~ 100% of rated current.
OUTPUT CURRENT
PROGRAMMABLE(PC)
Note 6
Please refer to the Function Manual.
FUNCTION
AUXILIARY POWER
REMOTE ON-OFF CONTROL
REMOTE SENSE
ALARM SIGNAL
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
5V @ 0.3A, 12V @ 0.8A
By electrical signal or dry contact
Power ON:short
Power OFF:open. Please refer to the Function Manual
Compensate voltage drop on the load wiring up to 0.5V. Please refer to the Function Manual
Isolated signal output for T-alarm and DC OK
-30 ~ +70
℃
(Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85
℃
, 10 ~ 95% RH
non-condensing
±
0.03%/
℃
(0 ~ 50
℃
)
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1
,
EAC TP TC 004 approved
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
℃
/ 70% RH
Parameter
Standard
Conducted
EMC EMISSION
Radiated
Harmonic Current
Voltage Flicker
SAFETY &
EMC
(Note 7)
Test Level / Note
EN55032 (CISPR32) / EN55011 (CISPR11) Class B
EN55032 (CISPR32) / EN55011 (CISPR11) Class A
EN61000-3-2
EN61000-3-3
Standard
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
EN61000-4-11
Class A
-----
Test Level / Note
Level 3, 8KV air ; Level 2, 4KV contact
Level 3
Level 3
Level 4, 2KV/Line-Line 4KV/Line-Earth
Level 3
Level 4
>95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
MIL-HDBK-217F (25
℃
)
EN55024 , EN61204-3, EN61000-6-2
Parameter
ESD
Radiated
EMC IMMUNITY
EFT / Burst
Surge
Conducted
Magnetic Field
Voltage Dips and Interruptions
MTBF
160.9K hrs min.
Telcordia SR-332 (Bellcore) ; 42.1K hrs min.
OTHERS
DIMENSION
PACKING
300*85*41mm (L*W*H)
2.1Kg;6pcs/13.6Kg/1.03CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25
℃
of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Under parallel operation ripple of the output voltage may be higher than the SPEC at light load condition. It will go back to normal ripple level once the
output load is more than 5%.
4. Tolerance : includes set up tolerance, line regulation and load regulation.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. PV/PC functions when users are not operating on PMBus/CANBus. SVR functions when users are neither operating on PMBus/CANBus nor using PV/PC.
7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a 720mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
8. The ambient temperature derating of 3.5
℃
/1000m with fanless models and of 5
℃
/1000m with fan models for operating altitude higher than 2000m(6500ft).
File Name:RSP-1600-SPEC 2018-01-15
1600W Power Supply with Single Output
Block Diagram
RSP-1600
series
PFC fosc : 90KHz
PWM fosc : 70KHz
+S
I/P
EMI
FILTER
ACTIVE
INRUSH
CURRENT
LIMITING
RECTIFIERS
&
PFC
POWER
SWITCHING
RECTIFIERS
&
FILTER
O.V.P.
DETECTION
CIRCUIT
TRANSCEIVERS
ORING
FET
+V
-V
-S
ORING FET
CONTROL
PV/PC
DA/DB
PFC
CONTROL
PWM
CONTROL
DETECTION
CIRCUIT
MCU
O.T.P.
AUX
POWER
FAN
MCU
(
RECTIFIERS
&
FILTER
12V/0.8A
AUX POWER
5V/0.3A
Remote ON-OFF
Static Characteristics
100
90
80
70
INPUT
MODEL
12V
1500W
125A
1200W
100A
1050W
87.5A
900W
75A
24V
1608W
67A
1286.4W
53.6A
1125.6W
46.9A
964.8W
40.2A
27V
1593W
59A
1274.4W
47.2A
1115.1W
41.3A
955.8W
35.4A
36V
1602W
44.5A
1281.6W
35.6A
1121.4W
31.15A
961.2W
26.7A
48V
1608W
33.5A
1286.4W
26.8A
1125.6W
23.45A
964.8W
20.1A
180~264VAC
115VAC
LOAD (%)
60
50
40
30
90
100
115
180
264
100VAC
90VAC
INPUT VOLTAGE (VAC) 60Hz
Derating Curve
Efficiency vs Load (48V Model)
94
93
100
80
92
91
230VAC
Input only
60
EFFICIENCY (%)
90
89
88
87
86
85
84
83
82
LOAD (%)
50
40
20
-30
-25
-10
0
15
30
50
60
70
(HORIZONTAL)
81
10%
20%
30%
40%
50%
60%
70%
80%
90% 100%
AMBIENT TEMPERATURE (
℃
)
LOAD
◎
The curve above is measured at 230VAC.
File Name:RSP-1600-SPEC 2018-01-15
(
DATA
ISOLATION
T-Alarm
DC-OK
SDA/SCL or
CANH/CANL
1600W Power Supply with Single Output
Function Manual
1.
Voltage Drop Compensation
1.1 Remote Sense
※
The Remote Sense compensates voltage drop on the load wiring up to 0.5V
RSP-1600
series
PIN15 +S
PIN16
-S
+V
LOAD
-
V
-V
CN1
+V
Sense lines should be twisted in pairs to minimize noise pick-up.
◎
The +S signal should be connected to the positive terminal of the load whereas -S signal to the negative terminal.
1.2 Local Sense
※
The +S,-S have to be connected to the +V(signal), -V(signal), respectively, as the following diagram, in order to get the correct output voltage if
Remote Sense is not used.
+V
PIN13 +V(signal)
PIN15 +S
PIN14 -V(signal)
PIN16 -S
LOAD
-
V
-V
CN1
+V
2. Output Voltage Programming (or, PV / remote voltage programming / remote adjust / margin programming / dynamic voltage trim)
※
In addition to the adjustment via the built-in potentiometer, the output voltage can be trimmed by applying EXTERNAL VOLTAGE.
PIN12 PV
PIN14
-V(signal)
-V
CN1
+V
EXTERNAL VOLTAGE (DC)
Vout
100
125
OUTPUT VOLTAGE(%)
OUTPUT CURRENT (%)
100
80
60
40
20
Non-Linear
12V
60
40
Others
0
0.4
1
4.7
5
40
60
80
100
125
V
V
OUTPUT VOLTAGE (%)
EXTERNAL VOLTAGE (DC)
◎
The rated current should change with the Output Voltage Programming accordingly.
◎
For Remote Sense / Local Sense, please refer to “Voltage Drop Compensation” section.
File Name:RSP-1600-SPEC 2018-01-15
1600W Power Supply with Single Output
RSP-1600
series
3. Constant Current Level Programming (or, PC / remote current programming / dynamic current trim)
※
The constant current level can be trimmed to 20~100% of the rated current by applying EXTERNAL VOLTAGE.
Iout
110
OUTPUT CURRENT (%)
100
PIN11 PC
PIN14
-V(signal)
Non-Linear
-V
CN1
+V
EXTERNAL VOLTAGE (DC)
◎
For Remote Sense / Local Sense, please refer to “Voltage Drop Compensation” section.
20
0.4 1
4.7 5
EXTERNAL VOLTAGE (VDC)
V
4. Remote ON-OFF Control
※
The power supply can be turned ON/OFF individually or along with other units by using the "Remote ON-OFF" function.
PIN3 +5V-AUX
switch
Between Remote ON-OFF and +5V-AUX
Switch Short
Power Supply Status
ON
OFF
PIN4 Remote ON-OFF
Switch Open
-V
CN1
+V
5. Alarm Signal Output
※
There are 2 alarm signals, DC OK and T-ALARM, in TTL signal form, on CN1. These signals are isolated from output. The maximum sink current