Technical Data Sheet
ADAPTOR
SnapN 50 JACK - RPC-N 50 PLUG
53QK105-S00S3
Dieses Dokument ist urheberrechtlich geschützt
●
This document is protected by copyright
●
Rosenberger Hochfrequenztechnik GmbH & Co. KG
All dimensions are in mm; tolerances according to ISO 2768 m-H
Interface
RPC-N according to
IEC 60169-16 ; CECC 22 210 ; MIL-STD 348A/304
N/A
Documents
Material and plating
Connector parts
Center contact
Outer contact
Coupling nut
Dielectric
Material
Beryllium copper
Stainless steel
Stainless steel
PPE
Plating
Gold, min. 1.27 µm, over chemical nickel
Passivated
Passivated
RF_35/09.14/6.2
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Email : info@rosenberger.de
Page
1/2
Technical Data Sheet
ADAPTOR
SnapN 50 JACK - RPC-N 50 PLUG
Electrical data
Impedance
Frequency
Return loss
Insertion loss
Insulation resistance
Center contact resistance
Outer contact resistance
Test voltage
(at sea level)
Working voltage
(at sea level)
RF-leakage
50
DC to 18 GHz
28 dB, DC to 11 GHz
26 dB, 11 GHz to 18 GHz
0.05 dB x
f [GHz]
dB
5 G
1 m
1 m
2500 V rms
500 V rms
90 dB @ DC to 1 GHz
500
200
28 N
1.70 Nm
0.70 Nm to 1.10 Nm
30 N typical
30 N typical
53QK105-S00S3
Dieses Dokument ist urheberrechtlich geschützt
●
This document is protected by copyright
●
Rosenberger Hochfrequenztechnik GmbH & Co. KG
Mechanical data
Mating cycles RPC-N
Mating cycles SnapN
Center contact captivation
Coupling test torque RPC-N
Recommended torque RPC-N
Engagement force SnapN
Disengagement force SnapN
Environmental data
Temperature range
Thermal shock
Corrosion
Vibration
Shock
Moisture resistance
RoHS
-40°C to +85°C
IEC 61169-1, Subclause 9.4.4
IEC 61169-1, Subclause 9.4.6
IEC 61169-1, Subclause 9.3.3
IEC 61169-1, Subclause 9.3.14
IEC 61169-1, Subclause 9.4.3
compliant
N/A
Tooling
Suitable cables
N/A
Weight
Weight
49.5 g/pce
While the information has been carefully compiled to the best of our knowledge, nothing is intended as representation or warranty on
our part and no statement herein shall be construed as recommendation to infringe existing patents. In the effort to improve our
products, we reserve the right to make changes judged to be necessary.
Draft
Andreas Fellner
Date
22/11/04
Approved
J_Gramsamer
Date
31.03.15
Rev.
c00
Engineering change number
15-0397
Name
J_Krautenbacher
Date
31.03.15
RF_35/09.14/6.2
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Email : info@rosenberger.de
Page
2/2