ELECTRICAL SOLUTIONS
Flex Conductor, One-Hole, Standard Barrel with Window, Flared NEBS Lug,
90° Angle
For Use with Flexible and Extra-Flexible Copper Conductors
Type LCAF-F
• Can be used with flex conductor class: K, M, and Diesel Locomotive
• Flared entry prevents bent back strands when inserting fine strand
conductor into barrel
• Color-coded barrels marked with Panduit die index numbers for
proper crimp die selection
• Inspection window to visually assure full conductor insertion
• Tin-plated to inhibit corrosion
• UL Listed and CSA Certified to 35 KV** and temperature rated to
90°C when crimped with Panduit crimping tools and dies
•
Tested by Telcordia
–
meets NEBS Level 3
• American Bureau of Shipping Approved
B2.
Cable
Accessories
A.
System
Overview
B1.
Cable Ties
B3.
Stainless
Steel Ties
W
INSPECTION
WINDOW
C1.
Wiring
Duct
T
90˚
C2.
Surface
Raceway
B
C3.
Abrasion
Protection
FLARED
ENTRY
L
Figure Dimensions
(In.)
Stud Hole
Size (In.)
#10
1/4
—
#8 AWG
5/16
3/8
#10
1/4
#6 AWG
#6 AWG
5/16
3/8
#10
1/4
#4 AWG
#4 AWG
5/16
3/8
1/4
5/16
#2 AWG
#2 AWG
3/8
1/2
1/4
5/16
#1 AWG
#1 AWG
3/8
1/2
1/4
5/16
1/0 AWG
1/0 AWG
3/8
1/2
W
0.41
0.48
0.56
0.60
0.45
0.48
0.56
0.62
0.55
0.55
0.55
0.62
0.70
0.70
0.70
0.79
0.76
0.76
0.76
0.80
0.85
0.85
0.85
0.85
B
0.76
0.76
0.76
0.76
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.88
0.88
0.88
0.88
0.94
0.94
0.94
0.94
1.35
1.35
1.35
1.35
T
0.08
0.07
0.05
0.05
0.09
0.08
0.07
0.06
0.09
0.09
0.09
0.07
0.11
0.11
0.11
0.09
0.12
0.12
0.12
0.12
0.13
0.13
0.13
0.13
L
0.93
1.02
1.14
1.24
1.52
1.06
1.18
1.28
1.07
1.16
1.28
1.38
1.35
1.48
1.55
1.79
1.49
1.54
1.62
1.85
1.64
1.70
1.70
1.95
C4.
Cable
Management
Panduit
Color
Code
Red
Red
Red
Red
Blue
Blue
Blue
Blue
Gray
Gray
Gray
Gray
Brown
Brown
Brown
Brown
Pink
Pink
Pink
Pink
Black
Black
Black
Black
Panduit
Die Index
No.‡
P21
P21
P21
P21
P24
P24
P24
P24
P29
P29
P29
P29
P33
P33
P33
P33
P42
P42
P42
P42
P45
P45
P45
P45
Std.
Wire Strip Pkg.
Length (In.) Qty.
13/16
50
13/16
13/16
13/16
7/8
7/8
7/8
7/8
7/8
7/8
7/8
7/8
15/16
15/16
15/16
15/16
1
1
1
1
1 7/16
1 7/16
1 7/16
1 7/16
50
50
50
50
50
50
50
50
50
50
50
20
20
20
20
10
10
10
10
10
10
10
10
Flex Conductor Size
Part Number
LCAF8-10F-L
LCAF8-14F-L
LCAF8-56F-L
LCAF8-38F-L
LCAF6-10F-L
LCAF6-14F-L
LCAF6-56F-L
LCAF6-38F-L
LCAF4-10F-L
LCAF4-14F-L
LCAF4-56F-L
LCAF4-38F-L
LCAF2-14F-E
LCAF2-56F-E
LCAF2-38F-E
LCAF2-12F-E
LCAF1-14F-X
LCAF1-56F-X
LCAF1-38F-X
LCAF1-12F-X
LCAF1/0-14F-X
LCAF1/0-56F-X
LCAF1/0-38F-X
LCAF1/0-12F-X
Class K and M
Diesel
Locomotive
D1.
Terminals
D2.
Power
Connectors
D3.
Grounding
Connectors
E1.
Labeling
Systems
E2.
Labels
E3.
Pre-Printed
& Write-On
Markers
E4.
Permanent
Identification
E5.
Lockout/
Tagout
& Safety
Solutions
F.
Index
‡See pages D3.74, D3.75 for tool and die information.
**Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 V.
Table continues on page D2.78
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
ELECTRICAL SOLUTIONS
A.
System
Overview
Flex Conductor, One-Hole, Standard Barrel with Window, Flared NEBS Lug,
90° Angle (continued)
Flex Conductor Size
Figure Dimensions
(In.)
Stud Hole
Size (In.)
1/4
5/16
2/0 AWG
2/0 AWG
3/8
1/2
1/4
5/16
3/0 AWG
3/0 AWG
3/8
1/2
1/4
5/16
4/0 AWG
4/0 AWG
3/8
1/2
3/8
1/2
250 kcmil
262.6 kcmil
5/8
7/8
3/8
1/2
300 kcmil
313.1 kcmil
5/8
7/8
3/8
1/2
5/8
350 kcmil
373.7 kcmil
3/4
7/8
1
1/2
400 kcmil
444.4 kcmil
5/8
7/8
W
0.96
0.96
0.96
0.96
1.06
1.06
1.06
1.06
1.17
1.17
1.17
1.17
1.28
1.28
1.28
1.28
1.39
1.39
1.39
1.39
1.54
1.54
1.54
1.54
1.54
1.54
1.70
1.70
1.70
B
1.35
1.35
1.35
1.35
1.35
1.35
1.35
1.35
1.35
1.35
1.35
1.35
1.65
1.65
1.65
1.65
1.65
1.65
1.65
1.65
1.85
1.85
1.85
1.85
1.85
1.85
2.20
2.20
2.20
T
0.13
0.13
0.13
0.13
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.17
0.17
0.17
0.17
0.18
0.18
0.18
0.18
0.22
0.22
0.22
0.22
0.22
0.22
0.26
0.26
0.26
L
1.71
1.71
1.77
2.02
1.81
1.82
1.89
2.12
1.88
1.90
1.97
2.20
2.21
2.32
2.53
2.97
2.44
2.44
2.65
3.04
2.40
2.40
2.77
2.91
3.16
3.28
3.28
3.28
3.28
Panduit
Color
Code
Orange
Orange
Orange
Orange
Purple
Purple
Purple
Purple
Yellow
Yellow
Yellow
Yellow
White
White
White
White
Red
Red
Red
Red
Blue
Blue
Blue
Blue
Blue
Blue
Brown
Brown
Brown
Panduit
Die Index
No.‡
P50
P50
P50
P50
P54
P54
P54
P54
P62
P62
P62
P62
P66
P66
P66
P66
P71
P71
P71
P71
P76
P76
P76
P76
P76
P76
P87
P87
P87
Std.
Wire Strip Pkg.
Length (In.) Qty.
1 7/16
10
1 7/16
1 7/16
1 7/16
1 7/16
1 7/16
1 7/16
1 7/16
1 7/16
1 7/16
1 7/16
1 7/16
1 3/4
1 3/4
1 3/4
1 3/4
1 3/4
1 3/4
1 3/4
1 3/4
1 15/16
1 15/16
1 15/16
1 15/16
1 15/16
1 15/16
2 1/4
2 1/4
2 1/4
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
6
6
6
6
6
6
6
6
6
6
6
6
6
B1.
Cable Ties
Diesel
Locomotive
B2.
Cable
Accessories
Part Number
LCAF2/0-14F-X
LCAF2/0-56F-X
LCAF2/0-38F-X
Class K and M
B3.
Stainless
Steel Ties
LCAF2/0-12F-X
LCAF3/0-14F-X
LCAF3/0-56F-X
LCAF3/0-38F-X
LCAF3/0-12F-X
LCAF4/0-14F-X
LCAF4/0-56F-X
LCAF4/0-38F-X
LCAF4/0-12F-X
LCAF250-38F-X
LCAF250-12F-X
LCAF250-58F-X
LCAF250-78F-X
LCAF300-38F-6
LCAF300-12F-6
LCAF300-58F-6
LCAF300-78F-6
LCAF350-38F-6
LCAF350-12F-6
C1.
Wiring
Duct
C2.
Surface
Raceway
C3.
Abrasion
Protection
C4.
Cable
Management
D1.
Terminals
LCAF350-58F-6
LCAF350-34F-6
LCAF350-78F-6
LCAF350-1F-6
LCAF400-12F-6
LCAF400-58F-6
LCAF400-78F-6
D2.
Power
Connectors
D3.
Grounding
Connectors
‡See pages D3.74, D3.75 for tool and die information.
**Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 V.
E1.
Labeling
Systems
E2.
Labels
E3.
Pre-Printed
& Write-On
Markers
E4.
Permanent
Identification
E5.
Lockout/
Tagout
& Safety
Solutions
F.
Index
Order number of pieces required, in multiples of Standard Package Quantity.
Prime items appear in
BOLD.