(measured @ Ta= 25°C, nom. Vin, full load and after warm up unless otherwise stated)
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Information Technology Equipment, General Requirements for Safety
Information Technology Equipment, General Requirements for Safety
EAC
RoHs 2+
Series
Report / File Number
1602031
E358085-A4-UL
RU-AT.49.09571
Standard
IEC60950-1:2005, 2nd Edition + A2:2013
EN60950-1:2006 + A2:2013
UL60950-1, 2nd Edition:2007
CAN/CSA C22.2 No. 60950-1-03, 2nd Edition:2007
TP TC 004/2011
RoHS-2011/65/EU + AM-2015/863
DIMENSION AND PHYSICAL CHARACTERISTICS
Parameter
Material
Dimension (LxWxH)
Weight
Type
case
potting
PCB
Value
non-conductive black plastic (UL94 V-0)
epoxy, (UL94 V-0)
FR4, (UL94 V-0)
11.5 x 6.0 x 10.0mm
1.4g typ.
Dimension Drawing (mm)
embossed logo
11.5
6.0
Pinning information
10.0
Marking
4.10
0.51
+0.10/-0.05
1.90
0.25
±0.05
Recommended Footprint Details
2.54
2.54
Pin #
1
2
3
4
Tolerance:
xx.x= ±0.5mm
xx.xx= ±0.25mm
Single
-Vin
+Vin
-Vout
+Vout
0.51
7.62
Bottom View
PACKAGING INFORMATION
Parameter
Packaging Dimension (LxWxH)
Packaging Quantity
Storage Temperature Range
Storage Humidity
1.25
1 2 3 4
1 2 3 4
Top View
Type
tube
tube
Value
520.0 x 16.0 x 9.0mm
42pcs
-55°C to + 125°C
95% RH max.