https://www.phoenixcontact.com/us/products/1517039
Sensor/actuator box - SACB-6/12-10,0PUR SCO - 1517039
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://download.phoenixcontact.com)
Sensor/actuator box, Connection method: M12-SPEEDCON-socket Metal, Number of slots: 6, Number
of positions: 5, Slot assignment: Double, Status indication: No, Universal; Master cable connection: Fixed
connection 180°, PUR/PVC, Cable length: 10 m, Shielding: No
Product Features
Safety in the field, thanks to molded housing and high degree of protection
Flexible, distributed bundling of signals in one master cable
Save space: distributor box with double occupancy for two sensors in one slot
Save time, thanks to installation with SPEEDCON fast locking system
Key commercial data
Packing unit
Weight per Piece (excluding packing)
Custom tariff number
Country of origin
1 PCE
2075.5 GRM
85444290
Poland
Technical data
General
Rated voltage
Max. operating voltage U
max
Current carrying capacity per I/O signal
Current carrying capacity per slot
Total rated current
Number of positions
Number of slots
Inflammability class according to UL 94
Sensor/actuator connection system
120 V
135 V
2A
4A
12 A
5
6
V0
M12-SPEEDCON-socket
Ambient conditions
12/2/13 Page 1 / 7
https://www.phoenixcontact.com/us/products/1517039
Sensor/actuator box - SACB-6/12-10,0PUR SCO - 1517039
Technical data
Ambient conditions
Degree of protection
IP65
IP67
IP69K
Ambient temperature (operation)
-30 °C ... 90 °C
-40 °C ... 90 °C (for fixed installation)
-5 °C ... 80 °C (for flexible installation)
Master cable connection data
Connection method
Length of cable
Tightening torque slot sensor/actuator cable
Fixed connection
10 m
0.4 Nm
Insulation material
Housing material
Material of the moulding mass
Contact material
Contact surface material
Contact carrier material
Material of threaded sleeve
Material of threaded sleeve surface
Material, O-ring
PBT
PUR
Cu alloy
Gold-plated
PA
Zinc die-cast
Nickel-plated
NBR
Pin assignment
Slot/position = Wire color or connection
1 / 4 (A) = WH
1 / 2 (B) = GY/PK
2 / 4 (A) = GN
2 / 2 (B) = RD/BU
3 / 4 (A) = YE
3 / 2 (B) = WH/GN
4 / 4 (A) = GY
4 / 2 (B) = BN/GN
5 / 4 (A) = PK
5 / 2 (B) = WH/YE
6 / 4 (A) = RD
6 / 2 (B) = YE/BN
1-6 / 1 (+ 120 V) = BN
1-6 / 3 (0 V) = BU
1-6 / 5 (PE) = GN/YE
12/2/13 Page 2 / 7
https://www.phoenixcontact.com/us/products/1517039
Sensor/actuator box - SACB-6/12-10,0PUR SCO - 1517039
Technical data
Cable
Cable type
Cable type (abbreviation)
Cable abbreviation
UL AWM style
Conductor cross section
AWG signal line
AWG power supply
Conductor structure signal line
Conductor structure, voltage supply
Core diameter including insulation
Thickness, insulation
Overall twist
External sheath, color
External cable diameter D
Minimum bending radius, fixed installation
Minimum bending radius, flexible installation
Number of bending cycles
Bending radius
Traversing path
Traversing rate
Cable weight
Outer sheath, material
Material, inner sheath
Material conductor insulation
Conductor material
Nominal voltage, cable
Test voltage, cable
Special properties
Flame resistance
Resistance to oil
Other resistance
Ambient temperature (operation)
PUR/PVC black
PUR
LiYY11Y-HF
20549
12x 0.5 mm² (signal line)
3x 1 mm² (power line)
20
17
28x 0.15 mm
56x 0.15 mm
1.5 mm ±0.1 mm (signal line)
2.1 mm ±0.1 mm (power line)
≥ 0.15 mm (Inner sheath)
≥ 0.76 mm (Outer cable sheath)
Wires twisted in layers
Black RAL 9005
9.4 mm ± 0.2 mm
7.5 x D
10 x D
1500000
94 mm
2m
2 m/s
150.9 kg/km
PUR
PVC
PVC
Bare Cu litz wires
300 V
2000 V
Silicone-free
DIN EN 50265
As per VDE 0472 Part 803
Highly resistant to acids, alkaline solutions and solvents
-40 °C ... 90 °C (cable, fixed installation)
-5 °C ... 80 °C (cable, flexible installation)
12/2/13 Page 3 / 7
https://www.phoenixcontact.com/us/products/1517039
Sensor/actuator box - SACB-6/12-10,0PUR SCO - 1517039
Classifications
eCl@ss
eCl@ss 4.0
eCl@ss 4.1
eCl@ss 5.0
eCl@ss 5.1
eCl@ss 6.0
eCl@ss 7.0
eCl@ss 8.0
27140815
27140815
27143423
27143423
27143423
27449001
27449001
ETIM
ETIM 2.0
ETIM 3.0
ETIM 4.0
ETIM 5.0
EC000200
EC001856
EC002585
EC002585
UNSPSC
UNSPSC 6.01
UNSPSC 7.0901
UNSPSC 11
UNSPSC 12.01
UNSPSC 13.2
31261501
31261501
31261501
31261501
31261501
Approvals
Approvals
Approvals
UL Recognized / cUL Recognized / GOST / cULus Recognized
Ex Approvals
Approvals submitted
Approval details
12/2/13 Page 4 / 7
https://www.phoenixcontact.com/us/products/1517039
Sensor/actuator box - SACB-6/12-10,0PUR SCO - 1517039
Approvals
UL Recognized
Nominal current IN
Nominal voltage UN
3A
120 V
cUL Recognized
Nominal current IN
Nominal voltage UN
3A
120 V
GOST
cULus Recognized
Accessories
Accessories
Device marking
Contactor marker – zack marker strip - SS-ZB 17,5 WH - 0804963
Contactor marker – zack marker strip, Strip, white, Unlabeled, Can be labeled with: Plotter, Mounting type: Snap into flat
marker groove, Lettering field: 17.5 x 8 mm
Protective cap
12/2/13 Page 5 / 7