Technical Data Sheet
Mini-SMP
Calibration Adaptor
Plug/Jack
18S121-K20D3
Dieses Dokument ist urheberrechtlich geschützt
●
This document is protected by copyright
●
Rosenberger Hochfrequenztechnik GmbH & Co. KG
All dimensions are in mm; tolerances according to ISO 2768 m-H
Interface
According to
MIL-STD-348
TM
Mateable with GPPO (Gilbert Engineering Co., Inc.)
TM
and SSMP (Connectors Devices, Inc.)
Documents
Application note
AN001 “Calibration Services”
Material and plating
Connector parts
Center conductor
Outer conductor
Dielectric
Material
CuBe
CuBe
PEEK
Plating
Gold, min. 1.27 µm, over nickel
Gold, min. 1.27 µm, over nickel
RF_35/09.14/6.2
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Email : info@rosenberger.de
Page
1/3
Technical Data Sheet
Mini-SMP
Calibration Adaptor
Plug/Jack
18S121-K20D3
Electrical data
Frequency range
Return loss
DC to 40 GHz
≥
24 dB, DC to 18 GHz
≥
16 dB, 18 GHz to 40 GHz
Dieses Dokument ist urheberrechtlich geschützt
●
This document is protected by copyright
●
Rosenberger Hochfrequenztechnik GmbH & Co. KG
Mechanical data
Mating cycles
if mating part is Smooth bore
if mating part is Full detent
Engagement force
- Smooth bore
- Full detent
Disengagement force
- Smooth bore
- Full detent
Gauge
≥
500
≥
100
11 N typical
19 N typical
11 N typical
29 N typical
0.00 mm to 0.08 mm
General standard definition
For proper operation the vector network analyzer (VNA) needs a model describing the electrical behaviour
of this calibration standard. The different models, units, and terms used will depend on the VNA type and they
will have to be entered into the VNA. All values are based on typical geometry and plating.
Offset Z
o
/ Impedance / Z
o
Offset Delay
Length (electrical) / Offset Length
Offset Loss
Loss
50
Ω
50.0346 ps
15.00 mm
4.00 GΩ/s
0.0348 dB/
GHz
Environmental data
Operating temperature range
2
Rated temperature range of use
Storage temperature range
RoHS
1
2
1
+ 20 °C to +26 °C
0 °C to +50 °C
- 40 °C to +85 °C
compliant
Temperature range over which these specification are valid.
This range is underneath and above the operating temperature range, within the calibration adaptor is fully functional
and could be used without damage.
RF_35/09.14/6.2
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Email : info@rosenberger.de
Page
2/3
Technical Data Sheet
Mini-SMP
Calibration Adaptor
Plug/Jack
18S121-K20D3
Declaration of calibration options
Factory Calibration
Standard delivery for this calibration standard includes a Factory Calibration. The Calibration Certificate
issued reports individual calibration results,
traceable to Rosenberger standards,
national / international
standards are not available. Model based standard definitions are reported in an Agilent/Keysight,
Rohde & Schwarz and Anritsu compatible VNA format.
Dieses Dokument ist urheberrechtlich geschützt
●
This document is protected by copyright
●
Rosenberger Hochfrequenztechnik GmbH & Co. KG
Accredited Calibration
Not available.
For further, more detailed information see application note AN001 on the Rosenberger homepage.
Calibration interval
Recommendation
12 months
Packing
Standard
Weight
1 pce in box
5.0 g/pce
While the information has been carefully compiled to the best of our knowledge, nothing is intended as representation or warranty on
our part and no statement herein shall be construed as recommendation to infringe existing patents. In the effort to improve our
products, we reserve the right to make changes judged to be necessary.
Draft
Marcel Panicke
Date
12.10.09
Approved
Markus Müller
Date
07.11.16
Rev.
f00
Engineering change number
15-1674
Name
Marion Striegler
Date
07.11.16
RF_35/09.14/6.2
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Email : info@rosenberger.de
Page