https://www.phoenixcontact.com/us/products/2904964
Repeater power supply - MACX PL-EX-RPSS-2I-2I-SP - 2904964
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Ex i measuring transducer repeater power supply, 2-channel; HART-transparent. Supplies Ex i 2-wire measuring
transducers and transmits the 4 - 20 mA signal from the Ex area to the safe area. 5-way electrical isolation, PLd,
spring-cage connection.
The figure shows a version with a
screw connection
Product Features
Key commercial data
Packing unit
Custom tariff number
Country of origin
1 pc
85437090
Germany
Technical data
Note
Utilization restriction
EMC: class A product, see manufacturer's declaration in the download
area
Dimensions
Width
Height
Depth
12.5 mm
99 mm
114.5 mm
Ambient conditions
Ambient temperature (operation)
Ambient temperature (storage/transport)
Maximum altitude
Permissible humidity (operation)
Noise immunity
-20 °C ... 60 °C (Any mounting position)
-40 °C ... 80 °C
≤ 2000 m
10 % ... 95 % (non-condensing)
EN 61000-6-2 When being exposed to interference, there may be minimal
deviations.
05/18/2015 Page 1 / 5
https://www.phoenixcontact.com/us/products/2904964
Repeater power supply - MACX PL-EX-RPSS-2I-2I-SP - 2904964
Technical data
Ambient conditions
Degree of protection
IP20
Input data
Signal input
Current input signal
Transmitter supply voltage
Intrinsically safe
4 mA ... 20 mA
> 16 V (at 20 mA)
Output data
Signal output
Current output signal
Transmission Behavior
Load/output load current output
Output behavior in the event of an error
Current output
4 mA ... 20 mA (active)
1:1 to input signal
≤ 450 Ω (20 mA)
≤ 375 Ω (24 mA)
< 3.6 mA (In the event of cable break at the input (as per NE 43))
> 22.5 mA (In the event of cable short circuit at the input (as per NE 43))
Power supply
Nominal supply voltage
Supply voltage range
Max. current consumption
Power consumption
24 V DC
19.2 V DC ... 30 V DC (24 V DC (-20% ... +25%))
< 100 mA (24 V / 20 mA)
< 1.4 W (at 24 V DC / 20 mA)
Connection data
Conductor cross section solid min.
Conductor cross section solid max.
Conductor cross section flexible min.
Conductor cross section flexible max.
Conductor cross section AWG min.
Conductor cross section AWG max.
Stripping length
Connection method
0.2 mm²
1.5 mm²
0.2 mm²
1.5 mm²
24
16
8 mm
Push-in connection
General
Maximum transmission error
Transmission error, typical
Maximum temperature coefficient
Step response (10-90%)
Status display
Inflammability class according to UL 94
Pollution degree
< 0.1 % (of final value)
< 0.05 % (of final value)
< 0.01 %/K
< 1.3 ms (for 4 mA ... 20 mA step)
Green LED (supply voltage)
V0
2
05/18/2015 Page 2 / 5
https://www.phoenixcontact.com/us/products/2904964
Repeater power supply - MACX PL-EX-RPSS-2I-2I-SP - 2904964
Technical data
General
Surge voltage category
Electromagnetic compatibility
Emitted interference
Color
Electrical isolation
II
Conformance with EMC Directive 2004/108/EC
EN 61000-6-4
yellow
300 V
rms
(Rated insulation voltage (surge voltage category II; pollution
degree 2, safe isolation as per EN 61010-1))
2.5 kV (50 Hz, 1 min., test voltage)
Designation
Electrical isolation
Designation
Electrical isolation
Designation
Electrical isolation
Conformance
ATEX
Input/output
375 V (Peak value in accordance with EN 60079-11)
Input/power supply
375 V (Peak value in accordance with EN 60079-11)
Output 1/output 2/ power supply
1.5 kV (50 Hz, 1 min., test voltage)
CE-compliant, additionally EN 61326
II (1) G [Ex ia Ga] IIC/IIB
II (1) D [Ex ia Da] IIIC
II 3(1) G Ex nA [ia Ga] IIC T4 Gc
IECEx
[Ex ia Ga] IIC/IIB
[Ex ia Da] IIIC
Ex nA [ia Ga] IIC T4 Gc
UL, USA / Canada
UL 61010 Listed
Data communication (bypass)
HART function
Protocols supported
Yes
HART
Safety data
Max. output voltage U
o
Max. output current I
o
Max. output power P
o
Group
Max. external inductivity L
o
Max. external capacity C
o
Group
Max. external inductivity L
o
Max. external capacity C
o
Safety-related maximum voltage U
m
25.2 V
93 mA
587 mW
IIC
2 mH
107 nF
IIB
4 mH
820 nF
253 V AC (125 V DC)
05/18/2015 Page 3 / 5
https://www.phoenixcontact.com/us/products/2904964
Repeater power supply - MACX PL-EX-RPSS-2I-2I-SP - 2904964
Classifications
eCl@ss
eCl@ss 5.1
eCl@ss 6.0
eCl@ss 8.0
27210121
27200206
27210121
ETIM
ETIM 4.0
ETIM 5.0
EC002653
EC002653
Approvals
Approvals
Approvals
UL Listed / cUL Listed / GL / Functional Safety / cULus Listed
Ex Approvals
ATEX / IECEx / UL Listed / cUL Listed / cULus Listed
Approvals submitted
Approval details
UL Listed
cUL Listed
GL
Functional Safety
05/18/2015 Page 4 / 5
https://www.phoenixcontact.com/us/products/2904964
Repeater power supply - MACX PL-EX-RPSS-2I-2I-SP - 2904964
Approvals
cULus Listed
Drawings
Block diagram
Sensor / Field
IN
OUT
PLC / DCS
AI
passive
4.2 - 4.2
CH1
+
4.1
4.1
HHT
3.2
active
3.1
3.2
3.1
-
+
HHT
CH1
5.2 - 5.2
CH2
+
5.1
5.1
HHT
active
2.2 2.2
CH2
2.1
2.1
-
passive
+
HHT
GND
+24V
Power
GND +24V
1.2
1.1
Zone 0,1,2
Zone 20,21,22
Div. 1,2
Zone 2
Div. 1
Phoenix Contact 2015 © - all rights reserved
http://www.phoenixcontact.com
05/18/2015 Page 5 / 5