Data sheet
RS ELCO
RS ELCOF 56/56RM S
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
D-32758 Detmold
Germany
Fon: +49 5231 1429-0
Fax: +49 5231 14292083
www.weidmueller.com
ELCO contacts inserts are used in electrical power plants,
refineries and a variety of process applications – wherever
stable and reliable signal transmission is required. The
ELCO connector features both a reliable connection
system and a high signal capacity.
The line of RS ELCO interfaces and pre-assembled PAC
ELCO cables is a specially designed solution for these
requirements.
General ordering data
Type
Order No.
Version
GTIN (EAN)
Qty.
RS ELCOF 56/56RM S
1480780000
Interface, RS ELCO, ELCO plug-in connector, 56,
LP2N 5.08mm
4050118289640
1 pc(s).
Creation date October 30, 2017 9:31:23 PM CET
Catalogue status 20.10.2017 / We reserve the right to make technical changes.
1
Data sheet
RS ELCO
RS ELCOF 56/56RM S
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
D-32758 Detmold
Germany
Fon: +49 5231 1429-0
Fax: +49 5231 14292083
www.weidmueller.com
Technical data
155 mm
70 mm
60 mm
175 g
Length (inches)
Width (inches)
Height (inches)
Dimensions and weights
Length
Width
Height
Net weight
6.102 inch
2.756 inch
2.362 inch
Temperatures
Operating temperature
-25...50 °C
Storage temperature
-40...60 °C
Connection Data
Connection on control side
Contact material (control side)
Connection (field side)
Earthing
ELCO plug-in connector
Phosphor bronze alloy
LP2N 5.08mm
No
Number of poles (control side)
Polarity hardware codification
Number of poles (field side)
56-pole female
1
56 P
Rating data
Rated voltage
Total operating current
150 V AC / 200 V DC
280 A
Rated current per connection
5A
Insulation coordination (EN50178)
According to
Surge voltage category
Pulse voltage test (1,2/50μs)
DIN EN 50178
II
2.5 kV
Rated insulation voltage
Pollution severity level
Insulation test voltage
< 150 V AC
2
0.8 kVAC
Connection field
Type of connection
Clamping range, max.
Solid, max. H05(07) V-U
Flexible, max. H05(07) V-K
Flexible with sleeve, min.
Min. wire cross-section, AWG
Tightening torque, min.
Stripping length
Clamping yoke connection
6 mm²
6 mm²
4 mm²
0.5 mm²
AWG 12
0.5 Nm
6 mm
Clamping range, min.
Solid, min. H05(07) V-U
Flexible, min. H05(07) V-K
Flexible with sleeve, max.
Sleeve with plastic collar, max.
Max. wire cross-section, AWG
Tightening torque, max.
0.13 mm²
0.5 mm²
0.5 mm²
2.5 mm²
2.5 mm²
AWG 26
0.6 Nm
Classifications
ETIM 4.0
eClass 6.2
EC000237
27-14-11-52
ETIM 6.0
eClass 9.1
EC002780
27-14-11-52
Product information
Descriptive text technical data
Descriptive text accessories
Polariser in position 1
Refer to the “PAC-ELCO universal cables” section in this chapter
Approvals
Approvals
Creation date October 30, 2017 9:31:23 PM CET
Catalogue status 20.10.2017 / We reserve the right to make technical changes.
2
Data sheet
RS ELCO
RS ELCOF 56/56RM S
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
D-32758 Detmold
Germany
Fon: +49 5231 1429-0
Fax: +49 5231 14292083
www.weidmueller.com
Technical data
Table of connections
Downloads
User Documentation
Creation date October 30, 2017 9:31:23 PM CET
Catalogue status 20.10.2017 / We reserve the right to make technical changes.
3
Data sheet
RS ELCO
RS ELCOF 56/56RM S
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
D-32758 Detmold
Germany
Fon: +49 5231 1429-0
Fax: +49 5231 14292083
www.weidmueller.com
Drawings
Creation date October 30, 2017 9:31:23 PM CET
Catalogue status 20.10.2017 / We reserve the right to make technical changes.
4