UZB12.121
U-Series
B
ATTERY
R
EPLACEMENT
12V, 12AH
B
ATTERY
R
EPLACEMENT
Maintenance-free VRLA Lead-Acid Battery
AGM (Absorbent Glass Mat) Technology
Can Be Installed in Any Orientation Except Permanently
Inverted
1. G
ENERAL
D
ESCRIPTION
The UZB12.121 is a non-spillable maintenance-free VRLA
lead-acid battery with absorbent glass mat (AGM)
technology. It can be used as a battery replacement for
many DC-UPS battery modules.
2. S
HORT
-
FORM
D
ATA
Nominal voltage
Nominal battery
capacity
Nominal battery life
Battery current
Recommended
charging voltage
DC 12V
12Ah
3 to 5 years
Max. 35A
Max. 3.5A
13.9V
13.75V
13.6V
13.45V
3%/month
-10°C to +40°C
-15°C to +50°C
Faston 250
6.35x0.8mm
151x100x98mm
4200g / 9.26lb
Capacity class
According EUROBAT
Discharging current
Charging current
At 10°C
At 20°C
At 30°C
At 40°C
At 20°C
For charging
For discharging
Self-discharge rate
Temperature range
Connection terminal
Size (WxHxD)
Weight
3. O
RDER
N
UMBERS
Battery Replacement
UZB12.121
4. M
ARKINGS
Aug. 2017 / Rev. 1.0 DS-UZB12.121
All parameters are typical values specified at, 25°C ambient temperature unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0
Germany
1/6
UZB12.121
U-Series
B
ATTERY
R
EPLACEMENT
12V, 12AH
I
NDEX
Page
1.
2.
3.
4.
5.
6.
7.
General Description ............................................1
Short-form Data ..................................................1
Order Numbers....................................................1
Markings ..............................................................1
Intended Use .......................................................3
Instructions for Disposal of the Batteries...........3
Instructions for Battery Storage .........................3
8.
9.
10.
11.
12.
Page
Installation Instructions...................................... 3
Environment ....................................................... 4
Fulfilled Standards.............................................. 4
Physical Dimensions and Weight ....................... 5
Recommendations for a Long Battery Life ....... 6
The information given in this document is correct to the best of our knowledge and experience at the time of
publication. If not expressly agreed otherwise, this information does not represent a warranty in the legal sense of the
word. As the state of our knowledge and experience is constantly changing, the information in this data sheet is
subject to revision. We therefore kindly ask you to always use the latest issue of this document (available under
www.pulspower.com).
No part of this document may be reproduced or utilized in any form without our prior permission in writing.
WARNING
Risk of electrical shock, fire, personal injury or death.
- Do not short-circuit the battery poles or power wires and always check correct battery polarity.
- Do not modify or repair the unit.
Aug. 2017 / Rev. 1.0 DS-UZB12.121
All parameters are typical values specified at, 25°C ambient temperature unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0
Germany
2/6
UZB12.121
U-Series
B
ATTERY
R
EPLACEMENT
12V, 12AH
5. I
NTENDED
U
SE
The battery is intended to be a replacement part for various DC-UPS battery modules.
6. I
NSTRUCTIONS FOR
D
ISPOSAL OF THE
B
ATTERIES
Batteries must be completely discharged before replacement and can be returned to the supplier of the battery
module or the battery manufacturer for disposal.
Always dispose batteries through a recycling organization.
7. I
NSTRUCTIONS FOR
B
ATTERY
S
TORAGE
Do not store batteries or battery modules at temperatures higher than 25°C or performance and lifetime may change.
Do not store discharged batteries. Keep batteries fully charged!
Charge retention is important to get the longest battery life. Stored batteries which are not fully charged age faster
then charged batteries.
Do not store batteries longer than 9 months without charging or performance and lifetime may change. Every 9
months or whenever the open circuit voltage (OCV) falls below 12.6V, the battery module should be charged. Apply a
charging voltage of 13.8V (at 25°C) for 72 hours. Batteries with an OCV below 12V must not be charged anymore and
must be disposed.
8. I
NSTALLATION
I
NSTRUCTIONS
Install batteries in an enclosure providing protection against electrical, mechanical and fire hazards.
Do not install the battery upside down.
Do not cover or block the pressure release valves on top of the battery.
Hydrogen gas can be released via pressure relief valves. It will form an explosive mixture in air when the concentration
exceeds 4% in volume. It is mandatory to ensure sufficient ventilation of the battery. The necessary air flow must be
calculated according to EN 50272-2.
CAUTION: The unit contains wet cell batteries. Ventilation of the installation room in accordance with the rules of
Canadian Electrical Code, part 1 is required if used in Canada.
The maximum surrounding air temperature is +50°C / +122°F. The operational temperature is the same as the ambient
or surrounding air temperature and is defined as the air temperature 2cm below the device.
Aug. 2017 / Rev. 1.0 DS-UZB12.121
All parameters are typical values specified at, 25°C ambient temperature unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0
Germany
3/6
UZB12.121
U-Series
B
ATTERY
R
EPLACEMENT
12V, 12AH
9. E
NVIRONMENT
Operational temperature
*)
-10°C to +40°C (14°F to 104°F)
For charging
Frequently charging below +5°C (41°F) reduced
the lifetime of the battery
For discharging
For storage and transportation
Recommendation:
Do not store at temperatures higher than 25°C
or performance and lifetime may change.
IEC 60068-2-30
Do not energize while condensation is present
Vibration in vertical mounting orientation
according to IEC/EN 61056-1
Shock with bottom down orientation
according to IEC/EN 61056-1
According to IEC 62477-1, not conductive
Storage temperature
-15°C to +50°C (5°F to 122°F)
-20°C to +50°C (-4°F to 122°F)
Humidity
Vibration sinusoidal
Shock
Altitude
Degree of pollution
*)
5 to 95% r.h.
±4mm at 16.7Hz
fixed frequency for 1hour
free fall from 20cm
onto a wooden floor
0 to 6000m (0 to 20 000ft)
2
Operational temperature is the same as the ambient temperature and is defined as the air temperature 2cm below the unit.
10. F
ULFILLED
S
TANDARDS
UL 1989
VDS
Component recognition - Stand-by batteries
UL Category BAZR2
VdS Schadenverhütung (Germany)
VdS Standard 2102 (Alarm Systems)
RoHS Directive
REACH Directive
IEC 61056
IEC
Batteries are exempt from the directive 2011/65/EU of the
European Parliament and the Council of June 8
th
, 2011 on the
restriction of the use of certain hazardous substances in
electrical and electronic equipment.
Directive 1907/2006/EU of the European Parliament and the
Council of June 1
st
, 2007 regarding the Registration,
Evaluation, Authorisation and Restriction of Chemicals
(REACH)
General purpose lead-acid batteries (valve-regulated types)
Aug. 2017 / Rev. 1.0 DS-UZB12.121
All parameters are typical values specified at, 25°C ambient temperature unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0
Germany
4/6
UZB12.121
U-Series
B
ATTERY
R
EPLACEMENT
12V, 12AH
11. P
HYSICAL
D
IMENSIONS AND
W
EIGHT
Width
Height
Height
Depth
Weight
151mm / 5.94’’
94mm / 3.70’’
100mm / 3.94’’
98mm / 3.86’’
4200g / 9.26lb
Fig. 11-1
Isometric view
Container height
With battery poles
All dimensions in mm
Aug. 2017 / Rev. 1.0 DS-UZB12.121
All parameters are typical values specified at, 25°C ambient temperature unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0
Germany
5/6