Non resettable fuses
www.schurter.com/pg0_2
Miniature Fuse, 5 x 20 mm, Super-Time-Lag TT, NF, 220 VAC
DTD
NF C 93-435 · 220 VAC · Super-Time-Lag TT
Description
Standards
- Low Breaking Capacity
- UL 248-14
- NF C 93-435 - Model HA20
- Contrôle de Conformité de Qualité (CCQ)
References
Weblinks
pdf, html, General Product Information, Approvals, RoHS, CHINA-RoHS,
e-Store, SCHURTER-Stock-Check, Distributor-Stock-Check
Approvals
- UL File Number: E42088
Technical Data
Rated Voltage
Rated Current
Breaking Capacity
Characteristic
Mounting
Admissible Ambient Air Temp.
Climatic Category
Material: Tube
Material: Endcaps
Unit Weight
Storage Conditions
Product Marking
32 - 220 VAC
0.031 - 15 A
40 A - 100 A
Super-Time-Lag TT
Fuseholder / Clip
-40 °C to 70 °C
40/070/56 acc. to IEC 60068-1
Glass
Nickel-Plated Copper Alloy
1.4 g
0 °C to 60 °C, max. 70% r.h.
Type, HA20, Current, Characteristic
20 mm
Resistance to Vibration
Shocks
Salt Mist
acc. to NF C 20-706 / IEC 60068-2-6,
test Fc
acc. to NF C 20-706 / IEC 60068-2-27
acc. to NF C 20-711 / IEC 60068-2-11
Dimensions
ø5
+0.2
0
20
±0.5
Pre-Arcing Time
Rated Current In
0.031 A - 1.25 A
1.6 A - 15 A
. x In min.
-
-
2.0 x In max.
10 min
-
2. x In max.
-
10 min
3.0 x In min.
1 s
1 s
3.0 x In max.
60 s
60 s
5.0 x In min.
300 ms
300 ms
5.0 x In max.
10 s
10 s
0.0 x In min.
30 ms
30 ms
Fuses
DTD
www.schurter.com/pg0_2
Variants
Rated Cur-
rent [A]
Rated Vol-
tage [VAC]
Breaking
Capacity
Voltage Drop
.0 In typ.
[mV]
3850
3150
2600
2000
1850
1600
2000
745
715
480
870
665
555
460
365
295
300
280
245
210
160
165
175
105
105
90
55
45
Power Dissi-
pation . I
n
typ. [mW]
145
155
160
155
180
190
300
150
180
150
340
340
360
370
370
365
465
535
595
630
615
790
1100
775
1000
1050
795
745
Melting I²t
0.0 Intyp.
[A²s]
0.079
0.2
0.22
0.35
0.26
0.028
0.61
0.2
0.39
0.4
0.21
0.64
1
1.6
4.2
9
7.1
22
43
128
370
260
440
800
1400
2200
890
3400
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
Order Number
Non resettable fuses
0.031
0.04
0.05
0.063
0.08
0.1
0.125
0.16
0.2
0.25
0.31
0.4
0.5
0.63
0.8
1
1.25
1.6
2
2.5
3.15
4
5
6.3
8
10
12.5
15
220
220
220
220
220
220
220
220
220
220
220
220
220
220
220
220
220
125
125
125
125
125
125
125
125
125
32
32
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
2)
2)
2)
2)
3)
3)
3)
4)
4)
5)
5)
7030.3110
7030.3120
7030.3130
7030.3140
7030.3150
7030.3210
7030.3220
7030.3230
7030.3240
7030.3250
7030.3260
7030.3270
7030.3280
7030.3290
7030.3310
7030.3320
7030.3330
7040.3110
7040.3120
7040.3130
7040.3140
7040.3150
7040.3160
7040.3170
7040.3180
7040.3190
7040.3200
7040.3210
1) NF: 60 A @ 220 VAC , p.f. = 1.0
1) UL: 4000 A @ 125 VAC , p.f. ≥ 0.9 / 4000 A @ 125 VDC , L/R = 5 ms
2) NF: 40 A @ 125 VAC , p.f. = 0.7 - 0.8
2) UL: 100 A @ 125 VAC , p.f. ≥ 0.9
3) NF: 40 A @ 125 VAC , p.f. = 0.7 - 0.8
3) UL: 50 A @ 125 VAC , p.f. ≥ 0.9
4) UL: 50 @ 125 VAC , p.f. ≥ 0.9
5) 100 A @ 32 VAC , p.f. ≥ 0.9
Packaging Unit
Small Box Pack (10 pcs.)
2
Fuses
Non resettable fuses
www.schurter.com/pg0_2
DTD
Time-Current-Curves
100000
≤
1.25 A
>
_
1.6 A
10000
1000
100
Time in Seconds
10
1
0.1
0.01
0.001
1
10
Multiple of Rated Current In
The specifications, descriptions and illustrations indicated in this document are based on
Fuses
current information. All content is subject to modifications and amendments.
3