760051581 | R-060-DS-CM-FMUAQ/8W024/5L036
TeraSPEED® Riser Distribution Cable, 60 fiber multi-unit with 12 fiber
subunits
Product Classification
Portfolio
Product Type
Regional Availability
CommScope®
Fiber indoor cable
Asia | Australia/New Zealand | EMEA | Latin America | North America
Standards And Qualifications
Cable Qualification Standards
ANSI/ICEA S-83-596 | Telcordia GR-409
Representative Image
General Specifications
Cable Type
Construction Type
Subunit Type
Distribution
Non-armored
Gel-free
Construction Materials
Fiber Type Solution
Total Fiber Count
Fiber Type
Fiber Type, quantity
Composite MM/SM | G.652.D and G.657.A1 , TeraSPEED® | OM3, LazrSPEED® 300
60
G.652.D and G.657.A1, TeraSPEED®
24
page 1 of 3
March 25, 2019
©2019 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: December 19, 2018
760051581 | R-060-DS-CM-FMUAQ/8W024/5L036
Fibers per Subunit, quantity
Jacket Color
Second Fiber Type
Second Fiber Type, quantity
12
Aqua
OM3, LazrSPEED® 300
36
Dimensions
Buffer Tube/Subunit Diameter
Cable Weight
Diameter Over Jacket
Subunit, quantity
5.95 mm | 0.23 in
187.0 lb/kft | 279.0 kg/km
17.88 mm | 0.70 in
5
Physical Specifications
Minimum Bend Radius, loaded
Minimum Bend Radius, unloaded
26.8 cm | 10.6 in
17.9 cm | 7.0 in
Tensile Load, long term, maximum
90 lbf | 400 N
Tensile Load, short term, maximum
300 lbf | 1335 N
Vertical Rise, maximum
146.0 m | 479.0 ft
Flame Test Specifications
Flame Test Listing
Flame Test Method
NEC OFNR (ETL) and c(ETL)
UL 1666
Environmental Specifications
Environmental Space
Installation Temperature
Operating Temperature
Storage Temperature
Riser
-20 °C to +70 °C (-4 °F to +158 °F)
-20 °C to +70 °C (-4 °F to +158 °F)
-40 °C to +70 °C (-40 °F to +158 °F)
Mechanical Test Specifications
Compression
Compression Test Method
Flex
Flex Test Method
Impact
Impact Test Method
Strain
Strain Test Method
Twist
10 N/mm | 57 lb/in
FOTP-41 | IEC 60794-1 E3
100 cycles
FOTP-104 | IEC 60794-1 E6
4.34 ft lb | 5.88 N-m
FOTP-25 | IEC 60794-1 E4
See long and short term tensile loads
FOTP-33 | IEC 60794-1 E1
10 cycles
page 2 of 3
March 25, 2019
©2019 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: December 19, 2018
760051581 | R-060-DS-CM-FMUAQ/8W024/5L036
Twist Test Method
FOTP-85 | IEC 60794-1 E7
Environmental Test Specifications
Heat Age
Heat Age Test Method
Low High Bend
Low High Bend Test Method
Temperature Cycle
Temperature Cycle Test Method
-20 °C to +85 °C (-4 °F to +185 °F)
IEC 60794-1 F9
-20 °C to +70 °C (-4 °F to +158 °F)
FOTP-37 | IEC 60794-1 E11
-20 °C to +70 °C (-4 °F to +158 °F)
FOTP-3 | IEC 60794-1 F1
Regulatory Compliance/Certifications
Agency
RoHS 2011/65/EU
ISO 9001:2015
Classification
Compliant
Designed, manufactured and/or distributed under this quality management system
Included Products
CS -5L-TB (Product Component—not orderable)
—
LazrSPEED ® 300 OM3 Bend-Insensitive Multimode Fiber
CS-5L-
Component—
LazrSPEED®
Bend-
CS -8W-TB (Product Component—not orderable)
—
TeraSPEED ® Singlemode Fiber
CS-8W-
Component—
TeraSPEED®
* Footnotes
Operating Temperature
Specification applicable to non-terminated bulk fiber cable
page 3 of 3
March 25, 2019
©2019 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: December 19, 2018