NUMBER
TYPE
GS-12-447
TITLE
PRODUCT SPECIFICATIONS
PAGE
REVISION
Metral RECEPTACLE F serieHM1 and NGEN versions
Straight and Right Angle PRESS-FIT
1 of 9
AUTHORIZED BY
DATE
C
2012-06-11
Terran Huang
CLASSIFICATION
UNRESTRICTED
1.0
OBJECTIVE
This specification defines the performance, test and reliability requirements of the Receptacle Straight and
Right Angle Press-Fit product.
2.0
SCOPE
This specification is applicable to the termination characteristics of the Metral RECEPTACLE, which
provides a separable, interconnect for printed circuit boards.
3.0
GENERAL
This document is composed of the following sections:
Paragraph
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
Title
OBJECTIVE
SCOPE
GENERAL
APPLICABLE DOCUMENTS
PERFORMANCE LEVELS
REQUIREMENTS
ELECTRICAL CHARACTERISTICS
MECHANICAL CHARACTERISTICS
ENVIRONMENTAL CONDITIONS
PACKAGING
3.1
Lead Free / RoHs informations
All product where the part number ends in ‘LF’ meet the European Union directives and
other country regulations as described in GS-22-008.
The part numbers that do not end in ‘LF’ meet all regulations except for Pb in SnPb plating.
Termination plating specification: 0.5µ to 3µ Nickel underlayer with 0.5µ to 1.5µ Pure TIN (matte)
Packaging specification: see GS-14-920
PDS: Rev :C
Copyright FCI
Form E-3334
Rev F
STATUS:Released
Printed: Jun 13, 2012
GS-01-001
NUMBER
TYPE
GS-12-447
TITLE
PRODUCT SPECIFICATIONS
PAGE
REVISION
Metral RECEPTACLE F serieHM1 and NGEN versions
Straight and Right Angle PRESS-FIT
2 of 9
AUTHORIZED BY
DATE
C
2012-06-11
Terran Huang
CLASSIFICATION
UNRESTRICTED
4.0
APPLICABLE DOCUMENTS
4.1
FCI Specifications
4.1.1 Engineering drawings: C-8626-xxxxx
4.2
Industry Product Specifications
4.2.1
IEC61076-4-104
Printed Board Connectors with Assessed Quality –Detail
Specification for Two-part Modular Connectors, Basis Grid of
2mm, with Terminations on a multiple Grid of 0.5mm
2 Millimeter, Two-Part Connectors for use with printed
Boards and Back planes
4.2.2
EIA616
4.3
Industry Performance Standards and Procedures
4.3.1
4.3.2
4.3.3
4.3.4
Telcordia GR-1217-CORE Generic Requirements for separable electrical connectors
Used in Telecommunications Hardware
EIA 364:
IEC 60512
IEC 60352-5
Electrical Connector/Socket test procedures including
Environmental Classifications.
Electromechanical components for electronic equipment,
Basic testing procedures and measuring methods
Solderless Press-in connections
General requirements, tests methods and practical guidance
4.5
Others Standards and Specifications
4.5.1
UL94-VO
Flammability
4.6
Tests Report
4.6.1
IEC Class 1
E91091
E93003
EA5-2705
R05-019
EA-1-2766
EA-1-2767
date: 10/12/1992 (FCI CRC)
date: 11/01/1993 (FCI CRC)
date: 21/08/2006 (FCI DB)
date: 10/12/1992 (FCI LFB)
date: 26/04/2002 (FCI DB)
date: 26/04/2002 (FCI DB)
4.6.2
Telcordia CO
PDS: Rev :C
Copyright FCI
Form E-3334
Rev F
STATUS:Released
Printed: Jun 13, 2012
GS-01-001
NUMBER
TYPE
GS-12-447
TITLE
PRODUCT SPECIFICATIONS
PAGE
REVISION
Metral RECEPTACLE F serieHM1 and NGEN versions
Straight and Right Angle PRESS-FIT
3 of 9
AUTHORIZED BY
DATE
C
2012-06-11
Terran Huang
CLASSIFICATION
UNRESTRICTED
5.0
PERFORMANCES LEVELS
Part Numbers:
HM1FxxxxxxxxH6(P)
HM1SxxxxxxxxH6(P)
HM1FxxxxxxxxH6(P)LF
HM1SxxxxxxxxH6(P)LF
or
52016-1yy , 85xxx-1yy
52016-1yyLF , 85xxx-1yyLF
(Specific for NGEN Straight)
These Part/Numbers meet requirements for
-IEC 61076-4-104 Class 1
-Telcordia GR-1217 CENTRAL OFFICE (CO), 4 Gazes
HM1 F serie
Ngen
6.0
REQUIREMENTS
6.1
Material
Contacts……………………………. Phosphor Bronze Alloy
Front housings
for HM1xxxxxxxxxH6(P
HM1xxxxxxxxxH6(P)LF ……..Glass filled LCP Thermoplastic, UL94V0 flammability rating
Or converged part Numbers
colour: Natural
Rear housings or Keepers……….Glass filled LCP Thermoplastic, UL94V0 flammability rating
colour: Natural
Contacts Finish (Plating)
The finish for applicable components shall be as specified herein or equivalent.
The terminals mating areas shall be plated with either
-Gold over Nickel 50u" (1.27µm) minimum underplate, or
-Gold over Palladium/Nickel over Nickel 50u" (1.27µm) minimum underplate.
-Pure TIN or TIN LEAD on Press-Fit areas over 50u" (1.27µm) minimum nickel underplate
6.2
PDS: Rev :C
Copyright FCI
Form E-3334
Rev F
STATUS:Released
Printed: Jun 13, 2012
GS-01-001
NUMBER
TYPE
GS-12-447
TITLE
PRODUCT SPECIFICATIONS
PAGE
REVISION
Metral RECEPTACLE F serieHM1 and NGEN versions
Straight and Right Angle PRESS-FIT
4 of 9
AUTHORIZED BY
DATE
C
2012-06-11
Terran Huang
CLASSIFICATION
UNRESTRICTED
6.3
PCB recommended layout
Receptacle for 4 row Press-fit and Straight
Receptacle for 5 row Press-fit and Straight
PDS: Rev :C
Copyright FCI
Form E-3334
Rev F
STATUS:Released
Printed: Jun 13, 2012
GS-01-001
NUMBER
TYPE
GS-12-447
TITLE
PRODUCT SPECIFICATIONS
PAGE
REVISION
Metral RECEPTACLE F serieHM1 and NGEN versions
Straight and Right Angle PRESS-FIT
5 of 9
AUTHORIZED BY
DATE
C
2012-06-11
Terran Huang
CLASSIFICATION
UNRESTRICTED
7.0
ELECTRICAL CHARACTERISTICS
7.1
Low Level Contact Resistance (LLCR)
The low level contact resistance shall not exceed the values shown below when measured in
accordance with IEC60512 test 2a (mated with Header)
-Signal contact Row A, B, C, D, E
7.2
: 20 mΩ Maximum
Insulation Resistance
The insulation resistance of unmated connector between to adjacent contacts shall not be less
than 5000 MΩ (megaOhms) initially, and shall not be less than1000 MΩ after environmental
exposure .Test in accordance with IEC60512 ,test 4a
Dielectric Withstanding Voltage
There shall be no evidence of arc-over, insulation breakdown, when a test voltage of 1000V rms is
applied. Test methodology in accordance with IEC60512,test 4a
7.3
7.4
Pin Current Capacity
7.4.1 Nominal Current
The nominal current carrying capacity shall be:
-1.5A (Amperes) per signal contact
-3A per power blade contact
when current is applied to all contacts. Test methodology in accordance to IEC60512,test 5b
7.4.2 Maximum Current capacity
The maximum current capacity shall be:
-Signal contact 2 A (Amperes) at 20°C / 1.5A at 70°C
7.5
Creepage and Clearance distances
The minimum distance for creepage and clearance is: 0.60mm
Wipping Length
The wipping length in plug in direction is: 2.0mm
When mating Header with Metral HEADER
Capacitance
The specification requirement shall be satisfied when evaluated in accordance with FCI Test
Specification BUS-03-114 and the following details:
a.
b.
Spécification requirement 2.2 pF max.
Sample test conditions
Frequency 1mhz
Amplitude 1volts
Surrounding Contacts tied to ground
7.6
7.7
PDS: Rev :C
Copyright FCI
Form E-3334
Rev F
STATUS:Released
Printed: Jun 13, 2012
GS-01-001