https://www.phoenixcontact.com/hq/products/1437740
Bus system flush-type plug - SACCBP-MSD-4CON-
PG9/2,0-931SCO - 1437740
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Bus system flush-type plug, Ethernet, 4-pos., M12 SPEEDCON, shielded, D-coded, rear/screw mounting with
Pg9 thread, with 2.0 m bus cable, 2 x 2 x 0.2 mm²
Key Commercial Data
Packing unit
GTIN
GTIN
Custom tariff number
Note
4046356458481
85444290
Made to Order (non-returnable)
1 STK
Technical data
Dimensions
Length of cable
2m
Ambient conditions
Ambient temperature (operation)
Degree of protection
-25 °C ... 90 °C (Plug / socket)
IP67
General
Rated current at 40°C
Rated voltage
Number of positions
Coding
Signal type/category
Overvoltage category
Degree of pollution
4A
250 V
4
D - data
Ethernet
II
3
Material
11/13/2016 Page 1 / 4
https://www.phoenixcontact.com/hq/products/1437740
Bus system flush-type plug - SACCBP-MSD-4CON-
PG9/2,0-931SCO - 1437740
Technical data
Material
Flammability rating according to UL 94
Contact material
Contact surface material
Contact carrier material
Material, knurls
Sealing material
V0
CuZn
Ni/Au
PA 66
Nickel-plated brass
NBR
Standards and Regulations
Flammability rating according to UL 94
V0
Cable
Cable type
Cable type (abbreviation)
UL AWM style
Signal type/category
Cable structure
Conductor cross section
AWG signal line
Conductor structure signal line
Core diameter including insulation
Wire colors
Twisted pairs
Overall twist
Shielding
Optical shield covering
External sheath, color
Outer sheath thickness
External cable diameter D
Minimum bending radius, fixed installation
Minimum bending radius, flexible installation
Tensile strength short-term/long-term
Cable weight
Outer sheath, material
Material conductor insulation
Conductor material
Standards/specifications
Insulation resistance
Loop resistance
Cable capacity
Wave impedance
PUR ETHERNET 2x2 FLEX
93E
20963 (80°C/30 V)
Ethernet CAT5 (IEC 11801), 100 Mbps
2x2xAWG26/7; SF/UTP
2x 2x 0.14 mm²
26
7x 0.16 mm
0.98 mm
white/orange-orange, white/green-green
2 cores to the pair
Two pairs with two fillers to the core
Aluminum-coated foil, tinned copper braided shield
70 %
water blue RAL 5021
1.2 mm
6.4 mm ±0.2 mm
4xD
8xD
≤ 80N
42 kg/km
PUR
Foamed PE
Bare Cu litz wires
Electrical requirements EN 50288-2-2
≥ 500 MΩ*km
≤ 290 Ω (per km)
approx. 45 nF/km (at 1 kHz)
100 Ω ±5 Ω (at 100 MHz)
11/13/2016 Page 2 / 4
https://www.phoenixcontact.com/hq/products/1437740
Bus system flush-type plug - SACCBP-MSD-4CON-
PG9/2,0-931SCO - 1437740
Technical data
Cable
Signal runtime
Coupling resistance
Nominal voltage, cable
Test voltage Core/Core
Test voltage Core/Shield
Flame resistance
Halogen-free
Resistance to oil
Ambient temperature (operation)
Ambient temperature (installation)
Ambient temperature (storage/transport)
5.3 ns/m
≤ 100.00 mΩ/m (At 10 MHz)
≤ 100 V (Peak value, not for high-power applications)
700 V (50 Hz, 1 min.)
700 V (50 Hz, 1 min.)
According to IEC 60332-1-2
in acc. to UL VW1
According to IEC 60754-1
according to EN 60811-2-1
-40 °C ... 80 °C (cable, fixed installation)
-20 °C ... 80 °C (cable, flexible installation)
-20 °C ... 80 °C
-20 °C ... 80 °C
Environmental Product Compliance
China RoHS
Environmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”,
Category “Manufacturer's declaration”
Drawings
Dimensional drawing
max.4,5
Schematic diagram
Ø15,3
+0,1
13,5
+0,1
1x45°
Pin assignment M12 male connector, 4-pos., D-coded, male side
Housing cutout for Pg9 fastening thread, mounting panel with feed-
through hole (alternatively with surface as protection against rotation)
Cable cross section
18
Dimensional drawing
2,8
17
M12x1
PG9
11
23
2
18
PUR ETHERNET 2x2 FLEX [93E]
M12 panel feed-through
11/13/2016 Page 3 / 4
https://www.phoenixcontact.com/hq/products/1437740
Bus system flush-type plug - SACCBP-MSD-4CON-
PG9/2,0-931SCO - 1437740
Circuit diagram
1
3
2
4
WH/OG
OG
WH/GN
GN
Contact assignment of the M12 plug
Approvals
Approvals
Approvals
UL Recognized / EAC
Ex Approvals
Approval details
UL Recognized
mm²/AWG/kcmil
Nominal current IN
Nominal voltage UN
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 118976
26-20
4A
250 V
EAC B.00767
Phoenix Contact 2016 © - all rights reserved
http://www.phoenixcontact.com
11/13/2016 Page 4 / 4