https://www.phoenixcontact.com/hq/products/1400402
Sensor/Actuator cable - SAC-3P-M12MS/ 3,0-PVC/M12FS - 1400402
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Sensor/Actuator cable, 3-position, PVC, black RAL 9005, Plug straight M12, A-coded, on Socket straight M12,
A-coded, Cable length: 3 m
Key Commercial Data
Packing unit
Minimum order quantity
GTIN
GTIN
Custom tariff number
Note
4046356494977
85444290
Made to Order (non-returnable)
1 STK
50 STK
Technical data
Dimensions
Length of cable
3m
Ambient conditions
Ambient temperature (operation)
Degree of protection
-25 °C ... 90 °C (Plug / socket)
IP65
IP67
IP68
General
Rated current at 40°C
Rated voltage
Number of positions
Insulation resistance
Coding
Status display
Overvoltage category
4A
250 V
3
≥ 100 MΩ
A - standard
No
II
11/13/2016 Page 1 / 4
https://www.phoenixcontact.com/hq/products/1400402
Sensor/Actuator cable - SAC-3P-M12MS/ 3,0-PVC/M12FS - 1400402
Technical data
General
Degree of pollution
Insertion/withdrawal cycles
Torque
3
≥ 100
0.4 Nm (M12 connector)
Material
Flammability rating according to UL 94
Contact material
Contact surface material
Contact carrier material
Material of grip body
Material, knurls
Sealing material
HB
CuSn
Ni/Au
TPU GF
TPU, hardly inflammable, self-extinguishing
Zinc die-cast, nickel-plated
NBR
Standards and Regulations
Flammability rating according to UL 94
HB
Cable
Cable type
Cable type (abbreviation)
Cable abbreviation
UL AWM style
Conductor cross section
AWG signal line
Conductor structure signal line
Core diameter including insulation
Thickness, insulation
Wire colors
Overall twist
External sheath, color
Outer sheath thickness
External cable diameter D
Minimum bending radius, fixed installation
Minimum bending radius, flexible installation
Cable weight
Outer sheath, material
Material conductor insulation
Conductor material
Insulation resistance
Conductor resistance
Nominal voltage, cable
Test voltage, cable
Flame resistance
PVC black
PVC
LiYY
2464 / 1729 (80°C/300 V)
3x 0.34 mm² (Signal line)
22
19x 0.15 mm
1.26 mm ±0.05 mm
≥ 0.23 mm (Core insulation)
brown, blue, black
3 wires, twisted
black RAL 9005
≥ 0.76 mm
4.3 mm ±0.2 mm
5xD
10 x D
40 kg/km
PVC
PVC
Bare Cu litz wires
≥ 100 MΩ*km (at 20 °C)
max. 57 Ω/km (at 20 °C)
≤ 300 V
≥ 2500 V
As per UL-Style 2464
11/13/2016 Page 2 / 4
https://www.phoenixcontact.com/hq/products/1400402
Sensor/Actuator cable - SAC-3P-M12MS/ 3,0-PVC/M12FS - 1400402
Technical data
Cable
Ambient temperature (operation)
-40 °C ... 80 °C (cable, fixed installation)
-25 °C ... 80 °C (cable, flexible installation)
Drawings
Schematic diagram
4
3
Schematic diagram
3
4
1
1
Pin assignment M12 plug, 3-pos., A-coded, view male side
Pin assignment M12 socket, 3-pos., A-coded, view female side
Cable cross section
Dimensional drawing
46,8
SW14
PVC black [PVC]
M12 x 1 plug, straight
Dimensional drawing
44
M12
M12 x 1 socket, straight
Approvals
Approvals
Approvals
UL Listed / cUL Listed / cULus Listed
SW14
Ø11
M12
Ø11
11/13/2016 Page 3 / 4
https://www.phoenixcontact.com/hq/products/1400402
Sensor/Actuator cable - SAC-3P-M12MS/ 3,0-PVC/M12FS - 1400402
Approvals
Ex Approvals
Approval details
UL Listed
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 221474
4A
300 V
Nominal current IN
Nominal voltage UN
cUL Listed
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 221474
4A
300 V
Nominal current IN
Nominal voltage UN
cULus Listed
Phoenix Contact 2016 © - all rights reserved