https://www.phoenixcontact.com/hq/products/1418862
Sensor/actuator box header - SACB-6/ 6-L-C GG SCO P NPN - 1418862
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Sensor/actuator box header, Application: Standard, Number of slots: 6, Number of positions: 4, Status
indication: Yes
Key Commercial Data
Packing unit
Minimum order quantity
GTIN
GTIN
Custom tariff number
Note
4055626153315
85366990
Made to Order (non-returnable)
1 STK
50 STK
Technical data
General
Rated voltage
Max. operating voltage U
max
Current carrying capacity per I/O signal
Current carrying capacity per slot
Total rated current
Number of positions
Number of slots
Flammability rating according to UL 94
24 V DC
30 V DC
2A
4A
10 A
4
6
V0
Standards and Regulations
Standard designation
Standards/regulations
Flammability rating according to UL 94
M12 connector
IEC 61076-2-101
V0
Drawings
11/13/2016 Page 1 / 2
https://www.phoenixcontact.com/hq/products/1418862
Sensor/actuator box header - SACB-6/ 6-L-C GG SCO P NPN - 1418862
Schematic diagram
3
5
4
Dimensional drawing
42,6
1
5
15,6
4,5
122,8
Ø4,5
M12 slot, socket, 4-pos.
54
36
5
73
107
Approvals
Approvals
Approvals
UL Recognized / cUL Recognized / cULus Recognized
Ex Approvals
Approval details
UL Recognized
Nominal voltage UN
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 118976
24 V
cUL Recognized
Nominal voltage UN
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 118976
24 V
cULus Recognized
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
Phoenix Contact 2016 © - all rights reserved
http://www.phoenixcontact.com
11/13/2016 Page 2 / 2
16
1
2
3
5
B
B
B
B
A
A
A
A
B
B
A
A
4
6