https://www.phoenixcontact.com/hq/products/1404881
Sensor/Actuator cable - SAC-8P-M12MS/1-PVC/FS SHOBS
VA - 1404881
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Sensor/actuator cable, 8-pos., PVC, RAL 9005 (black), shielded, straight M12 male plug, A-coded, to straight
M12 female plug, A-coded, cable length: 1 m, with VA knurl
as illustrated but with VA knurl and
without PATGs
Key Commercial Data
Packing unit
Minimum order quantity
GTIN
GTIN
Custom tariff number
Note
4046356726894
85444290
Made to Order (non-returnable)
1 STK
50 STK
Technical data
Ambient conditions
Degree of protection
IP65
IP67
IP68
IP69K
General
Rated current at 40°C
Rated voltage
Number of positions
Insulation resistance
Coding
Status display
2A
30 V
8
≥ 100 MΩ
A - standard
No
11/13/2016 Page 1 / 3
https://www.phoenixcontact.com/hq/products/1404881
Sensor/Actuator cable - SAC-8P-M12MS/1-PVC/FS SHOBS
VA - 1404881
Technical data
General
Overvoltage category
Degree of pollution
Insertion/withdrawal cycles
II
3
≥ 100
Material
Flammability rating according to UL 94
Contact material
Contact surface material
Contact carrier material
Material of grip body
Material, knurls
Sealing material
HB
CuZn
Ni/Au
TPU GF
TPU, hardly inflammable, self-extinguishing
Stainless steel
NBR
Standards and Regulations
Flammability rating according to UL 94
HB
Cable
Note
Cable type
Cable type (abbreviation)
Cable abbreviation
Conductor cross section
AWG signal line
Conductor structure signal line
Core diameter including insulation
Thickness, insulation
Wire colors
Overall twist
Shielding
Optical shield covering
External sheath, color
External cable diameter D
Smallest bending radius, fixed installation
Smallest bending radius, movable installation
Cable weight
Outer sheath, material
Material, filler
Material conductor insulation
Conductor material
The cable is not suitable for use with drag chains.
PVC black
PVC
LiYF-C-Y
8x 0.25 mm² (Signal line)
24
32x 0.10 mm
1.5 mm ±0.05 mm (Signal line)
≥ 0.38 mm (Conductor insulation, signal line)
≥ 0.76 mm (Outer cable sheath)
white, brown, green, yellow, gray, pink, blue, red
8 wires around filler to the core, twisted in with additional Cu litz in the
wire outer godet
Tinned copper braided shield
85 %
black RAL 9005
7.7 mm ±0.2 mm
38.5 mm
77 mm
85 kg/km
PVC
PVC
PVC
Bare Cu litz wires
11/13/2016 Page 2 / 3
https://www.phoenixcontact.com/hq/products/1404881
Sensor/Actuator cable - SAC-8P-M12MS/1-PVC/FS SHOBS
VA - 1404881
Technical data
Cable
Insulation resistance
Conductor resistance
Nominal voltage, cable
Test voltage, cable
Ambient temperature (operation)
≥ 10 GΩ*km
≤ 78 Ω/km
300 V
3000 V
-25 °C ... 105 °C (cable, fixed installation)
Drawings
Schematic diagram
Schematic diagram
Pin assignment M12 plug, 8-pos., view plug side
Pin assignment M12 socket, 8-pos., A-coded, view female side
Dimensional drawing
Dimensional drawing
47,3
44,5
Ø14,8
Plug, M12 x 1, straight, shielded
M12 x 1 socket, straight, shielded
Circuit diagram
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Contact assignment of the M12 plug and the M12 socket
Phoenix Contact 2016 © - all rights reserved
http://www.phoenixcontact.com
11/13/2016 Page 3 / 3
Ø14,8
M12
Ø12
M12
Ø12