https://www.phoenixcontact.com/hq/products/1454710
Sensor/Actuator cable - SAC-3P-M12MS/ 1,5-802/B-1L-Z - 1454710
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Sensor/Actuator cable, 3-position, PUR halogen-free, welding sputter-resistant, highly flexible, gray RAL
7001, Plug straight M12, A-coded, on Valve connector B (10 mm), with 1 LED, connected with Z diode, Cable
length: 1.5 m
Key Commercial Data
Packing unit
GTIN
GTIN
Custom tariff number
Note
4046356578141
85444290
Made to Order (non-returnable)
1 STK
Technical data
Dimensions
Length of cable
1.5 m
Ambient conditions
Degree of protection
IP65
IP67
General
Rated current at 40°C
Rated voltage
Number of positions
Insulation resistance
Coding
Status display
Protective circuit/component
Overvoltage category
Degree of pollution
4A
24 V
3
≥ 100 MΩ
A - standard
1 LED
Z diode
III
3
Material
Flammability rating according to UL 94
Contact material
Contact surface material
HB
CuSn
Ni/Au
11/13/2016 Page 1 / 4
https://www.phoenixcontact.com/hq/products/1454710
Sensor/Actuator cable - SAC-3P-M12MS/ 1,5-802/B-1L-Z - 1454710
Technical data
Material
Contact carrier material
Material of grip body
Valve plug contact material
Valve plug contact surface material
Valve plug contact insert material
Material housing valve plug
Material, knurls
Sealing material
TPU GF
TPU
CuSn
Sn
PA 66
TPU
Zinc die-cast, nickel-plated
TPU (Seal molded)
Standards and Regulations
Flammability rating according to UL 94
HB
Cable
Note
Cable type
Cable type (abbreviation)
Cable abbreviation
Conductor cross section
AWG signal line
Conductor structure signal line
Core diameter including insulation
Wire colors
Overall twist
External sheath, color
External cable diameter D
Minimum bending radius, fixed installation
Minimum bending radius, flexible installation
Number of bending cycles
Bending radius
Traversing path
Traversing rate
Acceleration
Torsion force
Cable weight
Outer sheath, material
Material conductor insulation
Conductor material
Insulation resistance
Conductor resistance
Nominal voltage, cable
Test voltage, cable
Due to the extremely robust outer sheath, this cable should only be
stripped in 5 cm increments.
PUR, halogen-free, highly stranded, resistant to welding sparks, gray
802
Li12Y11Y-HF
3x 0.5 mm² (Signal line)
20
28x 0.15 mm
1.5 mm ±0.05 mm (Signal line)
black 1, black 2, green/yellow
Wires twisted in layers
gray RAL 7001
4.5 mm ±0.2 mm
5xD
5xD
15000000
50 mm
0.9 m
5 m/s
30 m/s²
± 360 °/m
31 kg/km
PUR
PES
Bare Cu litz wires
≥ 20 MΩ*km
39 Ω/km (at 20 °C)
300 V
1200 V
11/13/2016 Page 2 / 4
https://www.phoenixcontact.com/hq/products/1454710
Sensor/Actuator cable - SAC-3P-M12MS/ 1,5-802/B-1L-Z - 1454710
Technical data
Cable
Special properties
Sheath resistant to welding beads, can be recycled, matt, without
adhesion, wear-resistant, flame resistant and self-extinguishing
Free from silicone and cadmium
Free of substances which would hinder coating with paint or varnish
Flame resistance
DIN VDE 0472 part 804, test type B
IEC 60332-1
in acc. with UL FT-2
Halogen-free
Resistance to oil
Other resistance
Ambient temperature (operation)
The cable is halogen-free
As per VDE 0472 Part 803
Highly resistant to acids, alkaline solutions and solvents
-40 °C ... 90 °C (cable, fixed installation)
-30 °C ... 90 °C (cable, flexible installation)
to 120 °C (for 3000 h)
Drawings
Schematic diagram
4
5
3
Cable cross section
Pin assignment M12 plug, 3-pos., valve connector
PUR, halogen-free, highly stranded, resistant to welding sparks,
gray [802]
Dimensional drawing
Dimensional drawing
45
28
46,8
Ø14,8
2
20,5
10
1
Valve connector, type B
M12 x 1 plug, straight
M12
Ø11
11/13/2016 Page 3 / 4
https://www.phoenixcontact.com/hq/products/1454710
Sensor/Actuator cable - SAC-3P-M12MS/ 1,5-802/B-1L-Z - 1454710
Dimensional drawing
Circuit diagram
3
28,2
YE
9,9
4
5
Valve connector, type B, side view
2
1
PE
Contact assignment of M12 plug and valve connector
Phoenix Contact 2016 © - all rights reserved
http://www.phoenixcontact.com
11/13/2016 Page 4 / 4