https://www.phoenixcontact.com/hq/products/1563449
Bus system cable - SAC-4PM12MSD/3,0-936/BP-M12FSD - 1563449
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Bus system cable, PROFINET, 4-position, PE-X, black RAL 9005, shielded, Plug straight M12, Coding: D, on
Flush-type socket M12, Coding: D, Cable length: 3 m
Key Commercial Data
Packing unit
Minimum order quantity
GTIN
GTIN
Custom tariff number
Note
4046356304474
85444290
Made to Order (non-returnable)
1 STK
10 STK
Technical data
Dimensions
Length of cable
3m
Ambient conditions
Ambient temperature (operation)
Degree of protection
-25 °C ... 90 °C (Plug / socket)
IP65
IP67
General
Rated current at 40°C
Rated voltage
Number of positions
Coding
Signal type/category
Overvoltage category
Degree of pollution
Insertion/withdrawal cycles
4A
250 V
4
D - data
PROFINET
II
3
≥ 100
Material
Flammability rating according to UL 94
Contact material
Contact surface material
V0
CuSn
Ni/Au
11/13/2016 Page 1 / 3
https://www.phoenixcontact.com/hq/products/1563449
Bus system cable - SAC-4PM12MSD/3,0-936/BP-M12FSD - 1563449
Technical data
Material
Contact carrier material
Material of grip body
Material, knurls
Sealing material
PA 66
TPU, hardly inflammable, self-extinguishing
Zinc die-cast, nickel-plated
NBR
Standards and Regulations
Flammability rating according to UL 94
V0
Cable
Cable type
Cable type (abbreviation)
Cable structure
Conductor cross section
AWG signal line
Conductor structure signal line
Core diameter including insulation
Wire colors
Overall twist
Shielding
Optical shield covering
External sheath, color
Outer sheath thickness
External cable diameter D
Minimum bending radius, fixed installation
Minimum bending radius, flexible installation
Cable weight
Outer sheath, material
Material conductor insulation
Conductor material
Conductor resistance
Working capacitance
Wave impedance
Signal speed
Shield attenuation
Coupling resistance
Nominal voltage, cable
Test voltage, cable
Fire protection in rail vehicles
Ethernet
936
1x4xAWG22/7; SF/TQ
4x 0.34 mm²
22
7x 0.25 mm
1.95 mm
white-blue, orange-yellow
Star quad
Plastic-coated aluminum foil, tinned copper braided shield
100 %
black RAL 9005
≥ 0.8 mm
7.25 mm ±0,3 mm
6xD
10 x D
81 g/m
PE-X
PE-X
silver-plated Cu litz wires
≤ 54.4 Ω/km
≤ 65 pF (core-core)
≤ 100 pF (core-shield)
100 Ω ±5 Ω (f = 100 MHz)
66 c
40 dB (30 MHz ≤ f ≤ 100 MHz)
200.00 mΩ/m (f ≤ 30 MHz)
300 V AC
2000 V AC (50 Hz, 5 minutes)
BS 6853 (Category Ia, Ib, II)
GM/RT 2130 (Category Ia, Ib, II)
EN 45545 (Risk level HL1 - HL3)
DIN 5510 (Fire protection level 1, 2, 3, 4)
11/13/2016 Page 2 / 3
https://www.phoenixcontact.com/hq/products/1563449
Bus system cable - SAC-4PM12MSD/3,0-936/BP-M12FSD - 1563449
Technical data
Cable
NF F16-101 (Category A1, A2, B)
NF F16-101 (Class C/F0)
NFPA 130
UNI CEI 11170 (Risk level LR1 - LR4)
Flame resistance
EN 60332-1-2
EN 50266
EN 60332-3-25
NF C32-070, 2.1
NF C32-070, 2.2
UL 1685, 12 (FT4)
in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
Halogen-free
Resistance to oil
Other resistance
Concentration of fumes
According to EN 50267-2-1
according to IRM 902, 72 h at 100 °C
Resistance to fuels according to IRM 903, 168 h at 70 °C
BS 6853 D.8.7
EN 61034-2
UL 1685, 12 (FT4)
Fume corrosiveness
Fume toxicity
Ambient temperature (operation)
EN 50267-2-2
BS 6853 B.1
EN 50305, 9.2
-50 °C ... 90 °C (cable, fixed installation)
-40 °C ... 90 °C (cable, flexible installation)
Environmental Product Compliance
China RoHS
Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values
Drawings
Cable cross section
Circuit diagram
1
4
3
2
1
4
3
2
PROFINET railway applications [936]
Phoenix Contact 2016 © - all rights reserved
http://www.phoenixcontact.com
11/13/2016 Page 3 / 3