https://www.phoenixcontact.com/hq/products/1437766
Bus system flush-type socket - SACCBP-FSD-4CON-
PG9/0,5-933SCO - 1437766
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Bus system flush-type socket, PROFINET, 4-pos., M12, shielded, D-coded, SPEEDCON, rear/screw
mounting with Pg9 thread, with 0.5 m bus cable, 2 x 2 x 0.34 mm²
Why buy this product
Pre-assembled with cables in various standard lengths for immediate use
Customer-specific assemblies and cable lengths can be supplied
Sealed on the cable side for optimum tightness of seal
Cable designs for all common networks and fieldbuses
For high transmission safety: shield connection to the housing with optional EMC nut
Key Commercial Data
Packing unit
GTIN
GTIN
Custom tariff number
4046356458504
85444290
1 STK
Technical data
Dimensions
Length of cable
0.5 m
Ambient conditions
Ambient temperature (operation)
Degree of protection
-20 °C ... 60 °C (cable, fixed installation)
IP67
General
Note
The electrical and mechanical data specified assume that the connector
pair is correctly locked and mounted. If the connector is unlocked and if
there is a danger of contamination, the connector must be sealed using
a protective cap > IP54. Influences arising from litz wires, cables or PCB
assembly must also be taken into consideration.
11/13/2016 Page 1 / 4
https://www.phoenixcontact.com/hq/products/1437766
Bus system flush-type socket - SACCBP-FSD-4CON-
PG9/0,5-933SCO - 1437766
Technical data
General
Rated current at 40°C
Rated voltage
Rated surge voltage
Number of positions
Insulation resistance
Coding
Signal type/category
Overvoltage category
Degree of pollution
Insertion/withdrawal cycles
Torque
4A
250 V
2.5 kV
4
≥ 100 MΩ
D - data
PROFINET CAT5 (IEC 11801:2002)
II
3
≥ 100
2 Nm ... 3 Nm (Installation-side)
Material
Flammability rating according to UL 94
Contact material
Contact surface material
Contact carrier material
Sealing material
V0
CuZn
Ni/Au
PA 66
FKM
Standards and Regulations
Flammability rating according to UL 94
V0
Cable
Cable type
Cable type (abbreviation)
UL AWM style
Signal type/category
Cable structure
Conductor cross section
AWG signal line
Conductor structure signal line
Core diameter including insulation
Wire colors
Overall twist
Shielding
Optical shield covering
External sheath, color
Outer sheath thickness
External cable diameter D
Minimum bending radius, fixed installation
Minimum bending radius, flexible installation
PROFINET PVC stranded CAT5
93B
21694
PROFINET CAT5 (IEC 11801), 100 Mbps
1x4xAWG22/7; SF/TQ
4x 0.34 mm²
22
7x 0.25 mm
1.55 mm
White, yellow, blue, orange
Star quad
Aluminum-coated foil, tinned copper braided shield
85 %
green RAL 6018
approx. 0.9 mm
6.5 mm ±0.2 mm
3xD
7xD
11/13/2016 Page 2 / 4
https://www.phoenixcontact.com/hq/products/1437766
Bus system flush-type socket - SACCBP-FSD-4CON-
PG9/0,5-933SCO - 1437766
Technical data
Cable
Cable weight
Outer sheath, material
Material, inner sheath
Material conductor insulation
Conductor material
Insulation resistance
Loop resistance
Wave impedance
Signal speed
Signal runtime
Coupling resistance
Nominal voltage, cable
Test voltage Core/Core
Test voltage Core/Shield
Flame resistance
Resistance to oil
Other resistance
Ambient temperature (operation)
Ambient temperature (installation)
Ambient temperature (storage/transport)
67 kg/km
PVC
PVC
PE
Tin-plated Cu litz wires
≥ 500 MΩ*km
≤ 120 Ω (per km)
100 Ω ±15 Ω (at 100 MHz)
0.66 c
5.3 ns/m
≤ 20.00 mΩ/m (At 10 MHz)
600 V
2000 V (50 Hz, 1 min.)
2000 V (50 Hz, 1 min.)
According to UL 1685 (CSA FT 4)
Resistant to oil to a limited extent
UV resistant According to UL 1581, Section 1200
-40 °C ... 70 °C (cable, fixed installation)
-40 °C ... 70 °C (cable, flexible installation)
-20 °C ... 60 °C
-50 °C ... 70 °C
Environmental Product Compliance
China RoHS
Environmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”,
Category “Manufacturer's declaration”
Drawings
Dimensional drawing
max.4,5
Cable cross section
13,5
+0,1
1x45°
Housing cutout for Pg9 fastening thread, mounting panel with feed-
through hole (alternatively with surface as protection against rotation)
Ø15,3
+0,1
PROFINET PVC stranded CAT5 [93B]
11/13/2016 Page 3 / 4
https://www.phoenixcontact.com/hq/products/1437766
Bus system flush-type socket - SACCBP-FSD-4CON-
PG9/0,5-933SCO - 1437766
Dimensional drawing
18
18
2,8
18
6,25 Nm
17
2
6,5
M12 panel feed-through
Approvals
Approvals
Approvals
UL Recognized / EAC
Ex Approvals
Approval details
UL Recognized
mm²/AWG/kcmil
Nominal current IN
Nominal voltage UN
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 118976
26-20
4A
250 V
EAC B.00767
Phoenix Contact 2016 © - all rights reserved
http://www.phoenixcontact.com
PG9
11/13/2016 Page 4 / 4