https://www.phoenixcontact.com/hq/products/1400498
Sensor/Actuator cable - SAC-4P- 5,0-500/M12FS-2L 0,15 - 1400498
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Sensor/Actuator cable, 4-position, PVC, gray RAL 7001, free cable end, on Socket straight M12, A-coded,
with 2 LEDs, Cable length: 5 m
as in the figure, but gray conductor
Key Commercial Data
Packing unit
Minimum order quantity
GTIN
GTIN
Custom tariff number
Note
4046356498678
85444290
Made to Order (non-returnable)
1 STK
10 STK
Technical data
Dimensions
Length of cable
Stripping length of the free conductor end
5m
50 mm
Ambient conditions
Degree of protection
IP65
IP67
IP68
General
Rated current at 40°C
Rated voltage
Number of positions
Insulation resistance
Coding
Status display
4A
24 V
4
≥ 10 MΩ
A - standard
2 LEDs
11/13/2016 Page 1 / 4
https://www.phoenixcontact.com/hq/products/1400498
Sensor/Actuator cable - SAC-4P- 5,0-500/M12FS-2L 0,15 - 1400498
Technical data
General
Overvoltage category
Degree of pollution
Insertion/withdrawal cycles
II
3
≥ 100
Material
Flammability rating according to UL 94
Contact material
Contact surface material
Contact carrier material
Material of grip body
Material, knurls
Sealing material
HB
CuSn
Ni/Au
TPU GF
TPU, hardly inflammable, self-extinguishing
Zinc die-cast, nickel-plated
NBR
Standards and Regulations
Flammability rating according to UL 94
HB
Cable
Cable type
Cable type (abbreviation)
Cable abbreviation
UL AWM style
Conductor cross section
AWG signal line
Conductor structure signal line
Core diameter including insulation
Thickness, insulation
Wire colors
Overall twist
External sheath, color
Outer sheath thickness
External cable diameter D
Minimum bending radius, fixed installation
Minimum bending radius, flexible installation
Cable weight
Outer sheath, material
Material conductor insulation
Conductor material
Insulation resistance
Conductor resistance
Nominal voltage, cable
Test voltage, cable
Ambient temperature (operation)
PVC gray
PVC
LiYY
2464 / 1729 (80°C/300 V)
4x 0.34 mm² (Signal line)
22
19x 0.15 mm
1.26 mm ±0.05 mm
≥ 0.23 mm (Core insulation)
brown, white, blue, black
4 wires, twisted
gray
≥ 0.76 mm
4.7 mm ±0.15 mm
5xD
10 x D
40 kg/km
PVC
PVC
Bare Cu litz wires
≥ 200 MΩ*km (at 20 °C)
max. 57 Ω/km (at 20 °C)
≤ 300 V
≥ 3000 V
-40 °C ... 80 °C (cable, fixed installation)
11/13/2016 Page 2 / 4
https://www.phoenixcontact.com/hq/products/1400498
Sensor/Actuator cable - SAC-4P- 5,0-500/M12FS-2L 0,15 - 1400498
Technical data
Cable
-25 °C ... 80 °C (cable, flexible installation)
Drawings
Schematic diagram
3
4
Cable cross section
2
1
Pin assignment M12 socket, 4-pos., A-coded, view female side
PVC gray [PVC]
Circuit diagram
1
2
4
GN
YE
BN
WH
BK
Dimensional drawing
44,5
3
BU
Contact assignment of M12 sockets with LED
Socket M12 x 1, straight, with LED
Approvals
Approvals
Approvals
UL Listed / cUL Listed / cULus Listed
Ex Approvals
Approval details
UL Listed
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 221474
4A
11/13/2016 Page 3 / 4
Nominal current IN
Ø14,8
M12
Ø12
https://www.phoenixcontact.com/hq/products/1400498
Sensor/Actuator cable - SAC-4P- 5,0-500/M12FS-2L 0,15 - 1400498
Approvals
Nominal voltage UN
300 V
cUL Listed
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 221474
4A
300 V
Nominal current IN
Nominal voltage UN
cULus Listed
Phoenix Contact 2016 © - all rights reserved
http://www.phoenixcontact.com
11/13/2016 Page 4 / 4