https://www.phoenixcontact.com/hq/products/1401204
Panel feed-through - SACC-E-M12FS-5CON-PG9/1,0 VAPO - 1401204
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Sensor/actuator flush-type socket, 5-pos., M12, A-coded, front/screw mounting with Pg9 thread, with 1 m TPE
litz wire, 5 x 0.34 mm², stainless steel version, molded version
Key Commercial Data
Packing unit
GTIN
GTIN
Custom tariff number
Note
4046356538244
85444290
Made to Order (non-returnable)
1 STK
Technical data
Dimensions
Length of cable
1m
Ambient conditions
Degree of protection
IP67
IP69K
General
Rated current at 40°C
Rated voltage
Number of positions
Insulation resistance
Coding
Status display
Overvoltage category
Degree of pollution
4A
60 V
5
> 100 MΩ
A - standard
No
II
3
Material
11/13/2016 Page 1 / 3
https://www.phoenixcontact.com/hq/products/1401204
Panel feed-through - SACC-E-M12FS-5CON-PG9/1,0 VAPO - 1401204
Technical data
Material
Flammability rating according to UL 94
Contact material
Contact surface material
Contact carrier material
Material, knurls
Sealing material
V0
CuZn
Au
PA66 GF
Stainless steel
FKM
Cable
Cable type
Conductor cross section
AWG signal line
Conductor structure signal line
Core diameter including insulation
Thickness, insulation
Wire colors
Material conductor insulation
Conductor material
Insulation resistance
Conductor resistance
Nominal voltage, cable
Test voltage, cable
TPE litz wire
0.34 mm²
22
7x 0.25 mm
1.2 mm ±0.07 mm
0.21 mm
Black, brown,blue, white, gray
TPE
Tin-plated Cu litz wires
≥ 20 MΩ*km
≤ 57.6 Ω/km
300 V
2000 V AC
Standards and Regulations
Flammability rating according to UL 94
V0
Environmental Product Compliance
China RoHS
Environmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”,
Category “Manufacturer's declaration”
Drawings
Dimensional drawing
°
45
Schematic diagram
3
5
4
PG9
Ø16
2
1
Housing cutout for Pg9 fastening thread, mounting panel with thread
Pin assignment M12 socket, 5-pos., A-coded, socket side view
11/13/2016 Page 2 / 3
https://www.phoenixcontact.com/hq/products/1401204
Panel feed-through - SACC-E-M12FS-5CON-PG9/1,0 VAPO - 1401204
Dimensional drawing
500
20
11,5
2
2
4
WH
BK
BU
GY
1
BN
Circuit diagram
PG 9
3
5
min.2,5
17
M12 flush-type connector
Contact assignment of the M12 plug and the M12 socket
Approvals
Approvals
Approvals
UL Recognized / EAC
Ex Approvals
Approval details
UL Recognized
mm²/AWG/kcmil
Nominal current IN
Nominal voltage UN
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 118976
26-20
4A
60 V
EAC B.00767
Phoenix Contact 2016 © - all rights reserved