VOLTAGE RANGE 50 to 1000 Volts CURRENT 4.0 Amperes
FEATURES
*
*
*
*
*
Ideal for printed circuit board
Surge overload rating: 150 amperes peak
Mounting position: Any
Weight: 4.8 grams
Molded structure
SINGLE-PHASE GLASS PASSIVATED
SILICON BRIDGE RECTIFIER
RS401L
THRU
RS407L
MECHANICAL DATA
* UL listed the recognized component directory, file #E94233
* Epoxy: Device has UL flammability classification 94V-O
.580 (14.7)
.540 (13.7)
.768 (19.5)
.728 (18.5)
RS-4L
.640 (16.3)
.600 (15.2)
.052 (1.3)
DIA.
.048 (1.2)
.750
(19.0)
MIN.
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
.083
(2.1)
.220 (5.6)
.180 (4.6)
.256 (6.5)
.236 (6.0)
Dimensions in inches and (millimeters)
MAXIMUM RATINGS
(@ T
A
=25
O
C unless otherwise noted)
RATINGS
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
o
at T
A
= 50 C
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Typical Current Squarad Time
SYMBOL
V
RRM
V
RMS
V
DC
I
O
I
FSM
I
2
t
R
θ
JC
RS401L
50
35
50
RS402L
100
70
100
RS403L
200
140
200
RS404L
400
280
400
4.0
150
93.37
RS405L
600
420
600
RS406L
800
560
800
RS407L
1000
700
1000
UNITS
Volts
Volts
Volts
Amps
Amps
A
2
/Sec
0
Typical Thermal Resistance (Note 1)
Typical Junction Capacitance (Note 3)
Operating and Storage Temperature Range
10
28
40
-55 to + 150
C/ W
pF
0
R
θ
JA
C
J
T
J
, T
STG
C
ELECTRICAL CHARACTERISTICS
(@T
A
=25
O
C unless otherwise noted)
CHARACTERISTICS
Maximum Instantaneous Forward Voltage at 4.0A DC
Maximum DC Reverse Current
at Rated DC Blocking Voltage
@T
A
= 25 C
@T
A
= 100 C
o
o
SYMBOL
V
F
I
R
RS401L
RS402L
RS403L
RS404L
1.1
2.0
200
RS405L
RS406L
RS407L
UNITS
Volts
uAmps
2016-09
REV: B
NOTES : 1. Thermal Resistance : Heat-sink case mounted or if PCB mounted.
2. "Fully ROHS compliant", "100% Sn plating (Pb-free)".
3. Measureed at 1MHz and applied reverse voltage of 4.0 volts.
RATING AND CHARACTERISTICS CURVES ( RS401L THRU RS407L )
INSTANTANEOUS FORWARD CURRENT, (A)
4.0
AVERAGE FORWARD CURRENT, (A)
3.2
2.4
40
10
4
1.6
Single Phase Half Wave
60 Hz Inductive or
Resistive Load
1
0.4
T
A
= 25
O
C
Pulse Width = 300mS
1% Duty Cycle
0.8
0
0
50
100
O
0.1
150
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
AMBIENT TEMPERATURE, ( C)
INSTANTANEOUS FORWARD VOLTAGE, (V)
FIG.1 TYPICAL FORWARD CURRENT
DERATING CURVE
INSTANTANEOUS REVERSE CURRENT, (
?
A)
PEAK FORWARD SURGE CURRENT, (A)
FIG.2 TYPICAL INSTANTANEOUS
FORWARD CHARACTERISTICS
180
150
120
90
60
30
0
1
2
5
10
20
50
100
NUMBER OF CYCLES AT 60Hz
1000
T
A
= 100 C
O
8.3mS Single Half Sine-Wave
JEDEC Method
100
10
T
A
= 25
O
C
1.0
0.1
0
20
40
60
80
100
120
140
PERCENT RATED PEAK REVERSE VOLTAGE, (%)
FIG.3 TYPICAL REVERSE CHARACTERISTICS
FIG.4 MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
Marking Description
Rectron Logo
RS40XL
V Y WW
AC
1-------50V
2-------100V
3-------200V
4-------400V
Part No.
Voltage-code
5-------600V
6-------800V
7-------1000V
UL Logo
Year – code:
(Y: Last digit of year &
A:2010,B:2011......)
+
-
Week – code:
(WW:01~52)
PACKAGING OF DIODE AND BRIDGE RECTIFIERS
BULK PACK
PACKAGE
RS-4L
PACKING CODE
-B
EA PER BOX
300
INNER BOX SIZE
(mm)
230*162*52
CARTON SIZE
(mm)
502*251*126
EA PER CARTON
1,800
GROSS
WEIGHT(Kg)
11.3
TUBE PACK
PACKAGE
RS-4L
PACKING CODE
-C
EA PER BOX
750
INNER BOX SIZE
(mm)
540*118*118
CARTON SIZE
(mm)
560*259*144
EA PER CARTON
1,500
WEIGHT(Kg)
12.1
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liabi-
lity for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" paramet-
ers which may be included on RECTRON data sheets and/ or specifications ca-
n and do vary in different applications and actual performance may vary over ti-
me. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other rela-
ted applications where a failure or malfunction of component or circuitry may di-
rectly or indirectly cause injury or threaten a life without expressed written appr-
oval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rect-
ron Inc and its subsidiaries harmless against all claims, damages and expendit-
ures.