12
11
10
9
8
7
6
5
4
3
2
1
MATERIAL NUMBER CIRCUITS
DIM. A
30.90/[1.217]
40.90/[1.610]
50.90/[2.004]
60.90/[2.398]
70.90/[2.791]
30.90/[1.217]
40.90/[1.610]
50.90/[2.004]
60.90/[2.398]
70.90/[2.791]
DIM. B
H
G
43914-1001
43914-1002
43914-1003
43914-1004
43914-1005
43914-1101
43914-1102
43914-1103
43914-1104
43914-1105
6
8
10
12
14
6
8
10
12
14
45.70/[1.799]
55.70/[2.193]
65.70/[2.587]
75.70/[2.980]
85.70/[3.374]
45.70/[1.799]
55.70/[2.193]
65.70/[2.587]
75.70/[2.980]
85.70/[3.374]
POLARIZING WEBS
PRESENT
QTY.
0
NO
0
NO
0
OBSOLETE
NO
0
NO
0
NO
1
YES
2
YES
2
YES
2
YES
2
YES
NOTES:
MATERIAL : POLYESTER, U.L. 94V-0. COLOR: BLACK
PRODUCT SPEC.: PS-42815-001
USES STANDARD 42815 MINI-FIT SR. FEMALE CRIMP TERMINALS.
EACH WIRE MUST BE DRESSED SUCH THAT THE TERMINAL MAINTAINS ITS FREE FLOAT
WITHIN THE HOUSING.
5. TPA #43980 MUST ALWAYS BE USED WITH THIS CONNECTOR.
6. PART MATES WITH MOLEX HEADER 43915.
7. POLARIZING WEBS TO BE LOCATED BETWEEN CIRCUITS ON
EITHER END OF HOUSING OF THE CIRCUIT 1 ROW AS SHOWN.
EXCEPTION: THE 6 CIRCUIT HOUSING WILL HAVE A SINGLE WEB ON THE CIRCUIT 1 END.
1.
2.
3.
4.
H
G
ANTI-OVERSTRESS FEATURE
F
STEP 1. TERMINALS ARE TO BE ORIENTATED AND LOADED INTO HOUSING AS SHOWN.
F
TERMINAL WALL
FORWARD STOP
TERMINAL LATCH
10.00
±
0.13
TYP.
.394
±
.005
E
A
±
0.50
[
±
.020]
B
±
0.95
[
±
.037]
CIRCUIT #1 DESIGNATION
ENGRAVED NUMBER AND RIB
STEP 2. TERMINALS ARE LOADED WHEN SEATED AGAINST FORWARD STOP AND
TERMINAL LATCHES ARE SNAPPED BEHIND TERMINAL WALLS.
RETENTION FORCE AT THIS STAGE = 0.5 Kg.
E
D
POLARIZING WEBS (2 PLACES)
(SEE CHART AND NOTE 7)
12.40
±
0.20
.488
±
.008
D
1
20.80
±
0.50
.819
±
.020
C
C
BREAK-OFF TAB
FACING FORWARD
RETENTION STRAP
34.40
±
0.20
1.354
±
.008
RETENTION RAMP
B
3.50
±
0.25
.138
±
.010
24.80
±
0.90
.976
±
.035
* THIS PRODUCT MUST NEVER BE USED WITHOUT THE T.P.A *
B
THIS DRAWING CONTAINS INFORMATION THAT IS PROPRIETARY TO MOLEX ELECTRONIC TECHNOLOGIES, LLC AND SHOULD NOT BE USED WITHOUT WRITTEN PERMISSION
2017/12/20
2018/01/17
2018/01/17
DIMENSION UNITS
GENERAL TOLERANCES
(UNLESS SPECIFIED)
SCALE
MM/[INCH]
DRWN BY
DATE
2:1
1997/08/20
DATE
MM
INCH
±
±
±
±
±
4 PLACES
±
±
±
±
±
COMERCI
CHK'D BY
169759
ME
SGANGADHARDO
ISHWARG
3 PLACES
2 PLACES
1 PLACES
0 PLACES
RECEPTACLE HOUSING
DUAL ROW 6-14 CIRCUIT (MINI-FIT SR.)
T.P.A SHOWN INSTALLED
A
COMERCI
APPR BY
DATE
1997/08/25
RELEASE STATUS
FORMAT: Eng-lega-master-tb-prod-C
REVISION: C
DATE: 2017/02/06
P1
RELEASE DATE
2018/01/17
12:09:56
G
10
9
8
7
6
REV
STEP 3. AFTER TERMINALS ARE LOADED INTO HOUSING, T.P.A. IS TO BE "BROKEN OR CUT"
IN HALF, ORIENTATED AND INSTALLED IN THE DIRECTION SHOWN UNTIL THE
RETENTION STRAPS SNAP OVER THE RETENTION RAMPS. THIS PRODUCT MUST
NEVER BE USED WITHOUT THE INSTALLATION OF THE T.P.A
12
11
PRODUCT CUSTOMER DRAWING
1997/08/26
SERIES
MATERIAL NUMBER
CUSTOMER
FRY
DRAWING SIZE
A
EC NO:
DRWN:
CHK'D:
APPR:
ANGULAR TOL
±
DRAFT WHERE APPLICABLE
MUST REMAIN
WITHIN DIMENSIONS
THIRD ANGLE PROJECTION
43914
DOCUMENT NUMBER
SEE CHART
GENERAL MARKET
C
4
3
DOC TYPE
DOC PART
SHEET NUMBER
SD-43914-002
PSD
001
1 OF 1
1
5
2