https://www.phoenixcontact.com/hq/products/1546602
Sensor/Actuator cable - SAC-3P-M12MS/ 3,0-150/M12FR-2L - 1546602
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Sensor/Actuator cable, 3-position, PUR, orange RAL 2003, Plug straight M12, A-coded, on Socket angled
M12, A-coded, with 2 LEDs, Cable length: 3 m
As shown in the illustration but with
an orange conductor
Key Commercial Data
Packing unit
GTIN
GTIN
Custom tariff number
4046356128735
85444290
1 STK
Technical data
Dimensions
Length of cable
3m
Ambient conditions
Degree of protection
IP65
IP67
IP68
General
Rated current at 40°C
Rated voltage
Number of positions
Insulation resistance
Coding
Status display
Overvoltage category
Degree of pollution
4A
24 V
3
≥ 100 MΩ
A - standard
2 LEDs
II
3
11/13/2016 Page 1 / 4
https://www.phoenixcontact.com/hq/products/1546602
Sensor/Actuator cable - SAC-3P-M12MS/ 3,0-150/M12FR-2L - 1546602
Technical data
General
Insertion/withdrawal cycles
≥ 100
Material
Flammability rating according to UL 94
Contact material
Contact surface material
Contact carrier material
Material of grip body
Material, knurls
Sealing material
HB
CuSn
Ni/Au
TPU GF
TPU, hardly inflammable, self-extinguishing
Zinc die-cast, nickel-plated
NBR
Standards and Regulations
Flammability rating according to UL 94
HB
Cable
Cable type
Cable type (abbreviation)
Cable abbreviation
Conductor cross section
AWG signal line
Conductor structure signal line
Core diameter including insulation
Wire colors
Overall twist
External sheath, color
External cable diameter D
Smallest bending radius, fixed installation
Smallest bending radius, movable installation
Number of bending cycles
Bending radius
Traversing path
Traversing rate
Acceleration
Outer sheath, material
Material conductor insulation
Conductor material
Conductor resistance
Nominal voltage, cable
Test voltage, cable
Flame resistance
Other resistance
Ambient temperature (operation)
PUR irradiated halogen-free orange
150
D12YSL11X-OB
3x 0.34 mm² (Signal line)
22
42x 0.10 mm
1.05 mm ±0.05 mm (Signal line)
brown, blue, black
3 wires, twisted
orange RAL 2003
4.4 mm ±0.2 mm
13.5 mm
53 mm
5000000
44 mm
10 m
3 m/s
10 m/s²
PUR
PE
Bare Cu litz wires
max. 57 Ω/km
250 V (AC)
2000 V (50 Hz, 5 minutes)
According to DIN VDE 0472 Part 804
UV resistant
-50 °C ... 105 °C (cable, fixed installation)
11/13/2016 Page 2 / 4
https://www.phoenixcontact.com/hq/products/1546602
Sensor/Actuator cable - SAC-3P-M12MS/ 3,0-150/M12FR-2L - 1546602
Technical data
Cable
-40 °C ... 105 °C (cable, flexible installation)
Drawings
Schematic diagram
4
3
Schematic diagram
3
4
1
1
Pin assignment M12 plug, 3-pos., A-coded, view male side
Pin assignment M12 socket, 3-pos., A-coded, view female side
Cable cross section
Dimensional drawing
46,8
Ø14,8
PUR irradiated halogen-free orange [150]
M12 x 1 plug, straight
Dimensional drawing
Ø14,8
M12
1
M12
Circuit diagram
1
Ø11
4
4
GN
YE
Ø12
28
3
3
36,3
Contact assignment of M12 plugs / sockets with 3 LEDs
Socket M12 x 1, angled, with LED
Approvals
Approvals
Approvals
UL Listed / cUL Listed / cULus Listed
11/13/2016 Page 3 / 4
https://www.phoenixcontact.com/hq/products/1546602
Sensor/Actuator cable - SAC-3P-M12MS/ 3,0-150/M12FR-2L - 1546602
Approvals
Ex Approvals
Approval details
UL Listed
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 221474
4A
24 V
Nominal current IN
Nominal voltage UN
cUL Listed
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 221474
4A
24 V
Nominal current IN
Nominal voltage UN
cULus Listed
Phoenix Contact 2016 © - all rights reserved
http://www.phoenixcontact.com
11/13/2016 Page 4 / 4