https://www.phoenixcontact.com/hq/products/1412370
Bus system cable - SAC-M12FR/ 8,0-970/R4AQ - 1412370
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Bus system cable, VARAN, 6-position, SANTOPRENE halogen-free, black RAL 9005, shielded, Plug straight
RJ45, on Socket angled M12, Cable length: 8 m
As illustrated but with angled socket
Key Commercial Data
Packing unit
Minimum order quantity
GTIN
GTIN
Custom tariff number
Note
4046356959308
85444290
Made to Order (non-returnable)
1 STK
25 STK
Technical data
Dimensions
Length of cable
8m
General
Rated current at 40°C
Rated voltage
Number of positions
Signal type/category
Status display
Overvoltage category
Degree of pollution
2A
30 V
6
VARAN
No
I
1
Material
Flammability rating according to UL 94
Contact material
Contact surface material
V0
CuZn
Ni/Au
11/13/2016 Page 1 / 4
https://www.phoenixcontact.com/hq/products/1412370
Bus system cable - SAC-M12FR/ 8,0-970/R4AQ - 1412370
Technical data
Material
Contact carrier material
Material of grip body
Material, knurls
Additional material specifications
Color
TPU GF
TPU, hardly inflammable, self-extinguishing
Zinc die-cast, nickel-plated
PC (RJ45 contact carrier material)
PA (RJ45 housing material)
traffic grey A
Standards and Regulations
Flammability rating according to UL 94
V0
Cable
Cable type
Cable type (abbreviation)
Cable abbreviation
Cable structure
Conductor cross section
AWG signal line
AWG power supply
Conductor structure signal line
Conductor structure, voltage supply
Core diameter including insulation
Wire colors
Type of pair shielding
Overall twist
Shielding
External sheath, color
External cable diameter D
Smallest bending radius, fixed installation
Smallest bending radius, movable installation
Number of bending cycles
Bending radius
Traversing path
Traversing rate
Acceleration
Cable weight
Outer sheath, material
Material, inner sheath
Material, filler
Material conductor insulation
Conductor material
VARAN
970
Li9YD12Y
1x2xAWG22/19 + 1x4xAWG24/19
4x 0.25 mm² (Signal line)
2x 0.38 mm² (Power supply)
24
22
19x 0.13 mm
19x 0.16 mm
1.35 mm (Signal line)
1.5 mm (Power supply)
Brown, blue, white/orange, white/green, green, orange
Tinned copper braided shield, 95 % covering
1 star quad and 2 wires with 2 fillers
Tinned copper-braided shield, approx. 85% covering
black RAL 9005
7.8 mm ±0.2 mm
≥ 93 mm
≥ 93 mm
3000000
93 mm
2m
1 m/s
2 m/s²
81 kg/km
SANTOPRENE halogen-free
TPE
Yarn
PP
Bare Cu litz wires
11/13/2016 Page 2 / 4
https://www.phoenixcontact.com/hq/products/1412370
Bus system cable - SAC-M12FR/ 8,0-970/R4AQ - 1412370
Technical data
Cable
Insulation resistance
Conductor resistance
Transmission characteristics (category)
Working capacitance
Wave impedance
Nominal voltage, cable
Test voltage, cable
Halogen-free
Ambient temperature (operation)
5 GΩ*km (Data cable)
77 Ω/m (Data cable)
CAT5 (IEC 11801:2002)
50 nF (Data cable)
100 Ω ±15 %
125 V (Data cable)
48 V (Power supply)
2000 V (Power supply)
max. 700 V AC (Data cable)
in accordance with DIN EN 50267-2-1
-20 °C ... 80 °C (Cable)
Drawings
Schematic diagram
Cable cross section
Pin assignment M12 socket, 8-pos., A-coded, view female side
VARAN [970]
Dimensional drawing
Ø14,8
M12
16,05
Dimensional drawing
max. 59
14
Ø12
36,3
M12 x 1 socket, angled, shielded
RJ45 connector, IP20
11/13/2016 Page 3 / 4
14,6
28
https://www.phoenixcontact.com/hq/products/1412370
Bus system cable - SAC-M12FR/ 8,0-970/R4AQ - 1412370
Schematic diagram
8 7 6 5 4 3 2 1
Phoenix Contact 2016 © - all rights reserved
http://www.phoenixcontact.com
11/13/2016 Page 4 / 4