Beldfoil® with a drain wire and have numbered and color-coded PVC jackets, overall Beldfoil® shield/drain
wire + overall PVC jacket w/nylon rip cord.
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material Dia. (in.)
32
24
7x32
TC - Tinned Copper 0.024
64
Total Number of Conductors:
Insulation
Insulation Material:
Insulation Trade Name Insulation Material
Datalene®
Dia. (in.)
FHDPE - Foam High Density Polyethylene .068
Inner Shield
Inner Shield Material:
Inner Shield Trade Name Type Inner Shield Material
Beldfoil®
Coverage (%)
Tape Bonded Aluminum Foil-Polyester Tape 100
Inner Shield Drain Wire AWG:
AWG
24
Inner Shield Drain Wire Stranding:
Inner Shield Drain Wire Conductor Material:
Stranded
TC - Tinned Copper
Inner Jacket
Inner Jacket Material:
Inner Jacket Material
Nom. Dia. (in.)
PVC - Polyvinyl Chloride .167
Inner Jacket Color Code Chart:
Number Color
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
Brown and Numbered 1
Red and Numbered 2
Orange and Numbered 3
Yellow and Numbered 4
Green and Numbered 5
Blue and Numbered 6
Purple and Numbered 7
Gray and Numbered 8
White and Numbered 9
Black and Numbered 10
Tan and Numbered 11
Pink and Numbered 12
Gray/Brown Stripe and Numbered 13
Gray/Red Stripe and Numbered 14
Gray/Orange Stripe and Numbered 15
Gray/Yellow Stripe and Numbered 16
Gray/Green Stripe and Numbered 17
Gray/Blue Stripe and Numbered 18
Gray/Purple Stripe and Numbered 19
Gray/Gray Stripe and Numbered 20
Gray/White Stripe and Numbered 21
Gray/Black Stripe and Numbered 22
Gray/Tan Stripe and Numbered 23
Page 1 of 4
09-11-2017
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
1854f Multi-Conductor - Multi-Pair Snake Cable
24
25
26
27
28
29
30
31
32
Gray/Pink Stripe and Numbered 24
Blue/Brown Stripe and Numbered 25
Blue/Red Stripe and Numbered 26
Blue/Orange Stripe and Numbered 27
Blue/Yellow Stripe and Numbered 28
Blue/Green Stripe and Numbered 29
Blue/Blue Stripe and Numbered 30
Blue/Purple Stripe and Numbered 31
Blue/Gray Stripe and Numbered 32
Outer Shield
Outer Shield Material:
Outer Shield Trade Name Type Outer Shield Material
Beldfoil®
Coverage (%)
Tape Aluminum Foil-Polyester Tape 100
Outer Shield Drain Wire AWG:
AWG Stranding Drain Wire Conductor Material
16
Stranded
TC - Tinned Copper
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
PVC - Polyvinyl Chloride
Outer Jacket Ripcord:
Yes
Overall Cable
Overall Nominal Diameter:
1.210 in.
Pair
Pair Color Code Chart:
Number Color
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
Red & Black
Red & Black
Red & Black
Red & Black
Red & Black
Red & Black
Red & Black
Red & Black
Red & Black
Red & Black
Red & Black
Red & Black
Red & Black
Red & Black
Red & Black
Red & Black
Red & Black
Red & Black
Red & Black
Red & Black
Red & Black
Red & Black
Red & Black
Red & Black
Red & Black
Red & Black
Red & Black
Red & Black
Red & Black
Red & Black
Red & Black
Red & Black
Mechanical Characteristics (Overall)
Operating Temperature Range:
Bulk Cable Weight:
Max. Recommended Pulling Tension:
-30°C To +60°C
750 lbs/1000 ft.
538 lbs.
Page 2 of 4
09-11-2017
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
1854f Multi-Conductor - Multi-Pair Snake Cable
Min. Bend Radius/Minor Axis:
13.500 in.
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification:
CEC/C(UL) Specification:
EU Directive 2011/65/EU (ROHS II):
EU CE Mark:
EU Directive 2000/53/EC (ELV):
EU Directive 2002/95/EC (RoHS):
EU RoHS Compliance Date (mm/dd/yyyy):
EU Directive 2002/96/EC (WEEE):
EU Directive 2003/11/EC (BFR):
CA Prop 65 (CJ for Wire & Cable):
MII Order #39 (China RoHS):
Other Specification:
CMG
CMG
Yes
Yes
Yes
Yes
01/01/2004
Yes
Yes
Yes
Yes
AES/EBU
Flame Test
UL Flame Test:
CSA Flame Test:
UL1685 FT4 Loading
FT4
Plenum/Non-Plenum
Plenum (Y/N):
No
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Impedance (Ohm)
110
Nom. Inductance:
Inductance (µH/ft)
.18
Nom. Capacitance Conductor to Conductor:
Capacitance (pF/ft)
12
Nom. Capacitance Cond. to Other Conductor & Shield:
Capacitance (pF/ft)
26
Nominal Velocity of Propagation:
VP (%)
76
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft)
23.7
Nom. Attenuation:
Freq. (MHz) Attenuation (dB/100 ft.)
0.384
0.706
0.768
1.024
1.411
1.536
2.048
2.822
3.072
4.096
5.645
6.144
8.192
11.290
12.288
24.576
0.290
0.710
0.770
0.940
1.100
1.100
1.300
1.400
1.400
1.500
1.700
1.800
2.000
2.200
2.300
3.100
Page 3 of 4
09-11-2017
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
1854f Multi-Conductor - Multi-Pair Snake Cable
Notes (Overall)
Notes:
Pair jackets and shields are bonded so both strip simultaneously with automatic stripping equipment. Datalene® insulation features include low dielectric constant and a
dissipation factor for high-speed, low-distortion data handling. Physical properties include good crush resistance and light weight.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to
change without notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for
any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether
in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities
and in our Distributor’s inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is
correct to the best of Belden’s knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the
safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification.
Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the
product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 2014/35/EU).