https://www.phoenixcontact.com/hq/products/1414988
Sensor/Actuator cable - SAC-5P-MS/ 7,5-802 SCO - 1414988
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Sensor/Actuator cable, 5-position, PUR halogen-free, welding sputter-resistant, highly flexible, gray RAL
7001, Plug straight M12 SPEEDCON, A-coded, on free cable end, Cable length: 7.5 m
As illustrated, but SPEEDCON
Key Commercial Data
Packing unit
Minimum order quantity
GTIN
GTIN
Custom tariff number
Note
4055626036601
85444290
Made to Order (non-returnable)
1 STK
50 STK
Technical data
Dimensions
Length of cable
7.5 m
Ambient conditions
Ambient temperature (operation)
-25 °C ... 90 °C (Plug / socket)
General
Rated current at 40°C
Rated voltage
Number of positions
Insulation resistance
Coding
Standards/regulations
Status display
Protective circuit/component
Overvoltage category
4A
60 V
5
≥ 100 MΩ
A - standard
M12 connector IEC 61076-2-101
No
Unwired
II
11/13/2016 Page 1 / 4
https://www.phoenixcontact.com/hq/products/1414988
Sensor/Actuator cable - SAC-5P-MS/ 7,5-802 SCO - 1414988
Technical data
General
Degree of pollution
Insertion/withdrawal cycles
3
≥ 100
Material
Flammability rating according to UL 94
Contact material
Contact surface material
Contact carrier material
Material of grip body
Material, knurls
HB
CuSn
Ni/Au
TPU GF
TPU, hardly inflammable, self-extinguishing
Zinc die-cast, nickel-plated
Standards and Regulations
Standard designation
Standards/regulations
Flammability rating according to UL 94
M12 connector
IEC 61076-2-101
HB
Cable
Note
Cable type
Cable type (abbreviation)
Cable abbreviation
Conductor cross section
AWG signal line
Conductor structure signal line
Core diameter including insulation
Wire colors
Overall twist
External sheath, color
External cable diameter D
Minimum bending radius, fixed installation
Minimum bending radius, flexible installation
Number of bending cycles
Minimum bending radius, drag chain applications
Traversing path
Traversing rate
Acceleration
Number of bending cycles
Bending radius
Traversing path
Traversing rate
Acceleration
Torsion force
Due to the extremely robust outer sheath, this cable should only be
stripped in 5 cm increments.
PUR, halogen-free, highly stranded, resistant to welding sparks, gray
802
Li12Y11Y-HF
5x 0.34 mm² (Signal line)
22
42x 0.10 mm
1.3 mm ±0.05 mm (Signal line)
Black, brown, blue, white, green/yellow
5 wires around filler to the core
gray RAL 7001
5.1 mm ±0.2 mm
5xD
5xD
10000000
7,5 x D
5m
3.3 m/s
5 m/s²
15000000
50 mm
0.9 m
5 m/s
30 m/s²
± 360 °/m (1,000,000 torsion cycles)
11/13/2016 Page 2 / 4
https://www.phoenixcontact.com/hq/products/1414988
Sensor/Actuator cable - SAC-5P-MS/ 7,5-802 SCO - 1414988
Technical data
Cable
Outer sheath, material
Material conductor insulation
Conductor material
Insulation resistance
Conductor resistance
Nominal voltage, cable
Test voltage, cable
Special properties
PUR
PES
Bare Cu litz wires
≥ 20 MΩ*km
approx. 53 Ω/km
300 V
1200 V
Sheath resistant to welding beads, can be recycled, matt, without
adhesion, wear-resistant, flame resistant and self-extinguishing
Free from silicone and cadmium
Free of substances which would hinder coating with paint or varnish
Flame resistance
DIN VDE 0472 part 804, test type B
IEC 60332-1
in acc. with UL FT-2
Halogen-free
Resistance to oil
Other resistance
Ambient temperature (operation)
The cable is halogen-free
As per VDE 0472 Part 803
Highly resistant to acids, alkaline solutions and solvents
-40 °C ... 90 °C (cable, fixed installation)
-30 °C ... 90 °C (cable, flexible installation)
to 120 °C (for 3000 h)
Drawings
Schematic diagram
4
5
3
Cable cross section
1
2
Pin assignment M12 male connector, 5-pos., A-coded, male side
PUR, halogen-free, highly stranded, resistant to welding sparks,
gray [802]
11/13/2016 Page 3 / 4
https://www.phoenixcontact.com/hq/products/1414988
Sensor/Actuator cable - SAC-5P-MS/ 7,5-802 SCO - 1414988
Dimensional drawing
1
46,8
2
WH
BK
BU
GN/YE
Circuit diagram
BN
Ø14,8
M12
Ø11
4
3
5
M12 x 1 plug, straight
Contact assignment of the M12 plug
Approvals
Approvals
Approvals
UL Listed / cUL Listed / cULus Listed
Ex Approvals
Approval details
UL Listed
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 221474
4A
125 V
Nominal current IN
Nominal voltage UN
cUL Listed
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 221474
4A
125 V
Nominal current IN
Nominal voltage UN
cULus Listed
Phoenix Contact 2016 © - all rights reserved
http://www.phoenixcontact.com
11/13/2016 Page 4 / 4