https://www.phoenixcontact.com/hq/products/1553569
Sensor/Actuator cable - SAC-8P-M12MS/50,0-850/M12FS HN - 1553569
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Sensor/Actuator cable, 8-position, PUR, black RAL 9005, Plug straight M12, A-coded, on Socket straight M12,
A-coded, Cable length: 50 m
Key Commercial Data
Packing unit
GTIN
GTIN
Custom tariff number
Note
4046356158367
85444290
Made to Order (non-returnable)
1 STK
Technical data
Dimensions
Length of cable
50 m
Ambient conditions
Degree of protection
IP65
IP67
IP68
General
Rated current at 40°C
Rated voltage
Number of positions
Insulation resistance
Coding
Status display
Overvoltage category
Degree of pollution
Insertion/withdrawal cycles
2A
30 V
8
≥ 100 MΩ
A - standard
No
II
3
≥ 100
Material
Flammability rating according to UL 94
Contact material
Contact surface material
HB
CuZn
Ni/Au
11/13/2016 Page 1 / 4
https://www.phoenixcontact.com/hq/products/1553569
Sensor/Actuator cable - SAC-8P-M12MS/50,0-850/M12FS HN - 1553569
Technical data
Material
Contact carrier material
Material of grip body
Material, knurls
Sealing material
TPU GF
TPU, hardly inflammable, self-extinguishing
Zinc die-cast, nickel-plated
NBR
Standards and Regulations
Flammability rating according to UL 94
HB
Cable
Cable type
Cable type (abbreviation)
Conductor cross section
AWG signal line
AWG power supply
Conductor structure signal line
Conductor structure, voltage supply
Core diameter including insulation
Thickness, insulation
Wire colors
Shielding
Optical shield covering
External sheath, color
External cable diameter
Smallest bending radius, fixed installation
Smallest bending radius, movable installation
Number of bending cycles
Bending radius
Outer sheath, material
Material, filler
Material conductor insulation
Conductor material
Insulation resistance
Conductor resistance
Working capacitance
Nominal voltage, cable
Test voltage Core/Core
Test voltage Core/Shield
Ambient temperature (operation)
PUR halogen-free black
850
4x 0.14 mm² (Signal line)
4x 0.34 mm² (Power supply)
26
22
19x 0.10 mm
45x 0.10 mm
1 mm (Signal line)
1.1 mm (Power supply)
≥ 0.38 mm (Outer cable sheath)
yellow, gray, violet, pink, white-green, brown-green, white, blue
Tinned copper braided shield
85 %
black RAL 9005
6.00 mm
≥ 20 mm
≥ 75 mm
5000000
75 mm
PUR
PE + filler yarn
Foamed PE (Signal line)
TPE (Power supply)
Tin-plated Cu litz wires
> 200 MΩ*km
≤ 134 mΩ/m (Signal line)
≤ 55 mΩ/m (Power supply)
≤ 40 pF (Signal line)
30 V
500 V AC (at 50 Hz)
500 V AC (at 50 Hz)
-40 °C ... 80 °C (cable, fixed installation)
11/13/2016 Page 2 / 4
https://www.phoenixcontact.com/hq/products/1553569
Sensor/Actuator cable - SAC-8P-M12MS/50,0-850/M12FS HN - 1553569
Technical data
Cable
-10 °C ... 80 °C (cable, flexible installation)
Drawings
Circuit
diagram
Schematic diagram
Contact
assignment
of
M12
connector/
Pin assignment M12 plug, 8-pos., view plug side
socket
Schematic diagram
3
5
4
Dimensional drawing
47,3
Ø14,8
M12
Pin assignment M12 socket, 5-pos., A-coded,
socket side view
Plug, M12 x 1, straight, shielded
Dimensional drawing
44,5
M12 x 1 socket, straight, shielded
Approvals
Approvals
Approvals
UL Listed / cUL Listed / cULus Listed
Ø14,8
M12
Ø12
Ø12
2
1
11/13/2016 Page 3 / 4
https://www.phoenixcontact.com/hq/products/1553569
Sensor/Actuator cable - SAC-8P-M12MS/50,0-850/M12FS HN - 1553569
Approvals
Ex Approvals
Approval details
UL Listed
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 221474
2A
30 V
Nominal current IN
Nominal voltage UN
cUL Listed
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 221474
2A
30 V
Nominal current IN
Nominal voltage UN
cULus Listed
Phoenix Contact 2016 © - all rights reserved
http://www.phoenixcontact.com