https://www.phoenixcontact.com/us/products/1524310
Bus system cable - SAC-4P-M12MSD/ 5,0-933 - 1524310
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Bus system cable, PROFINET CAT5 (100 Mbps), 4-position, PVC, green RAL 6018, shielded, Plug straight M12,
D-coded, on free cable end, Cable length: 5 m
Key Commercial Data
Packing unit
Weight per Piece (excluding packing)
Custom tariff number
Country of origin
1 pc
380.0 g
85444290
Poland
Technical data
Dimensions
Length of cable
Stripping length of the free conductor end
5m
50 mm
Ambient conditions
Ambient temperature (operation)
Degree of protection
-25 °C ... 90 °C (Plug / socket)
IP65
IP67
General
Note
Rated current at 40°C
Rated voltage
Number of positions
Insulation resistance
Coding
This product corresponds to the PROFINET Cabling and Interconnection
Technology Guideline for PROFINET regulations, version 2.00, order
no: 2.252, Chapter 8.2 Connectors for Outside Environment (Balanced
cabling)
4A
250 V
4
≥ 100 MΩ
D - data
04/15/2016 Page 1 / 4
https://www.phoenixcontact.com/us/products/1524310
Bus system cable - SAC-4P-M12MSD/ 5,0-933 - 1524310
Technical data
General
Signal type/category
Status display
Overvoltage category
Degree of pollution
Insertion/withdrawal cycles
PROFINET CAT5 (IEC 11801), 100 Mbps
No
II
3
≥ 100
Material
Flammability rating according to UL 94
Contact material
Contact surface material
Contact carrier material
Material of grip body
Material, knurls
V0
CuSn
Ni/Au
PA 66
TPU, hardly inflammable, self-extinguishing
Zinc die-cast, nickel-plated
Standards and Regulations
Flammability rating according to UL 94
V0
Cable
Cable type
Cable type (abbreviation)
Cable abbreviation
UL AWM style
Cable structure
Conductor cross section
AWG signal line
Conductor structure signal line
Core diameter including insulation
Wire colors
Overall twist
Shielding
Optical shield covering
External sheath, color
Outer sheath thickness
External cable diameter D
Minimum bending radius, fixed installation
Minimum bending radius, flexible installation
Cable weight
Outer sheath, material
Material, inner sheath
PROFINET PVC stranded CAT5
93B
2YY(ST)CY
21694
1x4xAWG22/7; SF/TQ
4x 0.34 mm²
22
7x 0.25 mm
1.55 mm
White, yellow, blue, orange
Star quad
Aluminum-coated foil, tinned copper braided shield
85 %
green RAL 6018
approx. 0.9 mm
6.5 mm ±0.2 mm
3xD
7xD
67 kg/km
PVC
PVC
04/15/2016 Page 2 / 4
https://www.phoenixcontact.com/us/products/1524310
Bus system cable - SAC-4P-M12MSD/ 5,0-933 - 1524310
Technical data
Cable
Material conductor insulation
Conductor material
Insulation resistance
Loop resistance
Wave impedance
Signal speed
Signal runtime
Coupling resistance
Nominal voltage, cable
Test voltage Core/Core
Test voltage Core/Shield
Flame resistance
Resistance to oil
Other resistance
Ambient temperature (operation)
PE
Tin-plated Cu litz wires
≥ 500 MΩ*km
≤ 120 Ω (per kilometer)
100 Ω ±15 Ω (at 100 MHz)
0.66 c
5.3 ns/m
≤ 20.00 mΩ/m (At 10 MHz)
600 V
2000 V (50 Hz, 1 min.)
2000 V (50 Hz, 1 min.)
According to UL 1685 (CSA FT 4)
Resistant to oil to a limited extent
UV resistant According to UL 1581, Section 1200
-40 °C ... 70 °C (cable, fixed installation)
-40 °C ... 70 °C (cable, flexible installation)
Classifications
eCl@ss
eCl@ss 4.0
eCl@ss 4.1
eCl@ss 5.0
eCl@ss 5.1
eCl@ss 6.0
eCl@ss 7.0
eCl@ss 8.0
eCl@ss 9.0
27060306
27060306
27061801
27061801
27061801
27061801
27279218
27060311
ETIM
ETIM 2.0
ETIM 3.0
ETIM 4.0
ETIM 5.0
EC000830
EC001855
EC001855
EC001855
UNSPSC
UNSPSC 6.01
UNSPSC 7.0901
31251501
31251501
04/15/2016 Page 3 / 4
https://www.phoenixcontact.com/us/products/1524310
Bus system cable - SAC-4P-M12MSD/ 5,0-933 - 1524310
Classifications
UNSPSC
UNSPSC 11
UNSPSC 12.01
UNSPSC 13.2
31251501
31251501
31251501
Drawings
Schematic diagram
Cable cross section
Pin assignment M12 male connector, 4-pos., D-coded, male side
PROFINET PVC stranded CAT5 [93B]
Circuit diagram
Dimensional drawing
1
2
3
4
YE
WH
47,3
Ø14,8
M12
OG
BU
Contact assignment of the M12 connector
Plug, M12 x 1, straight, shielded
Phoenix Contact 2016 © - all rights reserved
http://www.phoenixcontact.com
04/15/2016 Page 4 / 4
Ø12