86081-6020

产品描述Fiber Optic Connector, 9/125um, Single Mode, Simplex
产品类别连接器   
文件大小152KB,共8页
制造商Molex
官网地址https://www.molex.com/molex/home
下载文档 详细参数 全文预览

86081-6020概述

Fiber Optic Connector, 9/125um, Single Mode, Simplex

86081-6020规格参数

参数名称属性值
是否无铅含铅
是否Rohs认证不符合
厂商名称Molex
Reach Compliance Codeunknown
ECCN代码EAR99
Is SamacsysN
连接类型SIMPLEX
连接器类型FIBER OPTIC CONNECTOR
联系完成配合NOT SPECIFIED
触点材料NOT SPECIFIED
耦合类型SNAP
DIN 符合性NO
光纤尺寸9/125um
IEC 符合性NO
插入损耗0.5 dB
MIL 符合性NO
制造商序列号86081
模式SINGLE
安装类型CABLE
选件GENERAL PURPOSE
Base Number Matches1

文档预览

下载PDF文档
FEATURES AND SPECIFICATIONS
Features and Benefits
Precision alignment pins improve insertion loss
performance
Fanouts to simplex fiber connectors require no splicing
resulting in cost reduction
MTP to HBMT and BMTP cable assemblies provide a
transition from the board to the backplane
Color coded housings ensure singlemode and multimode
assemblies are easily distinguished
Push-pull mating of MTP* for quick connections
Variety of MTP adapters facilitate multiple mounting
options for flexible board and panel layouts
*MTP is a registered trademark of US Conec Ltd.
Applications
Dense interconnect for datacommunication and
telecommunication systems
Chassis-to-chassis connections
Miniature interconnenction for optoelectronic modules
Reference Information
Connector Body Material: Polymer
Housing: UL V-0
MTP/MPO sold as terminations only
MTP*/MPO
Connectors and Adapters
MTP/MPO connectorized ribbon fiber cable assemblies provide
reliable high performance interconnects of up to 24 fibers in a
small footprint. The MTP/MPO connectors utilize the precision
molded NTT compatible ferrule which connects four to 24
fibers using bare ribbon or ruggedized ribbon cable.
Alignment between mating ferrules is accomplished using two
precision guide pins that are pre-installed into the designated
male connector.
MTP/MPO assemblies utilize a push-pull connector housing
for a quick and reliable connection. For optical device
interconnections, MTP/MPO assemblies interface on the
daughter card to Molex’s HBMT and BMTP adapters on the
backplane.
Multiple transitions between ribbon cable to individual fibers
are available to meet a variety of fiber routing requirements.
Fanouts to single fiber leads connectorized with Molex
industry standard LC, MU, FC, SC and ST connectors are
available to interconnect with the current installed base of
transmitters, receivers and patch panels.
A singlemode low loss version of the MTP/MPO connector is
achieved by using more precise MT 8-fiber ferrules and guide
pins. The superior precision of the singlemode low loss MT
ferrule yields comparable insertion loss values of the single
fiber ceramic ferrules.
MTP/MPO connectors meet IEC 1754-7 and TIA/EIA 604-5
standards.
Mating of the MTP/MPO connectors can be achieved by using
a variety of MTP/MPO adapters. For applications where EMI is
a concern, Molex has developed a series of shuttered die cast
adapters that are designed to shield and isolate EMI
emissions.
ORDERING INFORMATION
MTP Connectors
Part No.
86081-3030
86081-3020
86081-5020
86081-6020
86082-3030
86082-3020
86082-5020
86082-6020
Body
Male, Black
Male, Beige
Male, Green
Male, Yellow
Female, Black
Female, Beige
Female, Green
Female, Yellow
Mode
Multimode
Multimode
Singlemode
Singlemode
Multimode
Multimode
Singlemode
Singlemode
Insertion Loss At Test
.5dB
.5dB
.75dB
.5dB
.5dB
.5dB
.75dB
.5dB
Ferrule Hole Size
50/125lm
62.5/125lm
9/125lm
9/125lm
50/125lm
62.5/125lm
9/125lm
9/125lm
Ferrule Port
4, 8,12 or 24
4, 8,12 or 24
4, 8,12 or 24
8
4, 8,12 or 24
4, 8,12 or 24
4, 8,12 or 24
8
APC
Cable Type
Bare Ribbon / Jacketed
Bare Ribbon / Jacketed
Bare Ribbon / Jacketed
Bare Ribbon / Jacketed
Bare Ribbon / Jacketed
Bare Ribbon / Jacketed
Bare Ribbon / Jacketed
Bare Ribbon / Jacketed
Bare Ribbon / Jacketed
Boot
Black
Black
Black
Black
Black
Black
Black
Black
Black
Mates With
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP / BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
Yes
Yes
Yes
Yes
MPO Connectors
Part No.
86083-3093
86083-3090
86083-5090
86083-6094
86084-3093
86084-3090
86084-5090
86084-6094
86083-3095
86083-3092
86083-3096
86083-6099
86084-3095
86084-3092
86084-5096
86084-6099
86083-3094
86083-3091
86083-5002
86083-6098
86084-3094
86084-3091
86084-5097
86084-6098
Body
Male, Black
Male, Beige
Male, Green
Male, Yellow
Female, Black
Female, Beige
Female, Green
Female, Yellow
Male, Black
Male, Beige
Male, Green
Male, Yellow
Female, Black
Female, Beige
Female, Green
Female, Yellow
Male, Black
Male, Beige
Male, Green
Male, Yellow
Female, Black
Female, Beige
Female, Green
Female, Yellow
Mode
Multimode
Multimode
Singlemode
Singlemode
Multimode
Multimode
Singlemode
Singlemode
Multimode
Multimode
Multimode
Multimode
Multimode
Multimode
Singlemode
Singlemode
Multimode
Multimode
Multimode
Multimode
Multimode
Multimode
Singlemode
Singlemode
Insertion Loss At Test
.5dB
.5dB
.75dB
.5dB
.5dB
.5dB
.75dB
.5dB
.5dB
.5dB
.75dB
.5dB
.5dB
.5dB
.75dB
.5dB
.5dB
.5dB
.75dB
.5dB
.5dB
.5dB
.75dB
.5dB
Ferrule Hole Size
50/125lm
62.5/125lm
9/125lm
9/125lm
50/125lm
62.5/125lm
9/125lm
9/125lm
50/125lm
62.5/125lm
9/125lm
9/125lm
50/125lm
62.5/125lm
9/125lm
9/125lm
50/125lm
62.5/125lm
9/125lm
9/125lm
50/125lm
62.5/125lm
9/125lm
9/125lm
Ferrule Port
4, 8,12 or 24
4, 8,12 or 24
4, 8,12 or 24
8
4, 8,12 or 24
4, 8,12 or 24
4, 8,12 or 24
8
4, 8,12 or 24
4, 8,12 or 24
4, 8,12 or 24
8
4, 8,12 or 24
4, 8,12 or 24
4, 8,12 or 24
8
4, 8,12 or 24
4, 8,12 or 24
4, 8,12 or 24
8
4, 8,12 or 24
4, 8,12 or 24
4, 8,12 or 24
8
APC
Cable Type
Jacketed
Jacketed
Jacketed
Jacketed
Jacketed
Jacketed
Jacketed
Jacketed
Jacketed
Bare
Bare
Bare
Bare
Bare
Bare
Bare
Bare
Bare
Bare
Bare
Bare
Bare
Bare
Bare
Bare
Bare
Boot
Standard, Black
Standard, Black
Standard, Black
Standard, Black
Standard, Black
Standard, Black
Standard, Black
Standard, Black
Standard, Black
Long, Black
Long, Black
Long, Black
Long, Black
Long, Black
Long, Black
Long, Black
Long, Black
Long, Black
Short, Black
Short, Black
Short, Black
Short, Black
Short, Black
Short, Black
Short, Black
Short, Black
Short, Black
Mates With
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP / BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
MTP/BMTP Adapters
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Molex reserves the right to make any changes to the product(s) or information contained herein without notice. No liability is assumed as a result of their use or application.
1
MOLEX FIBER OPTICS DIVISION
5224 Katrine Avenue, Downers Grove, IL 60515 / Tel: 800-A1-FIBER or (630) 512-8787 Web: www.molex.com/fiber
电子电学计算软件
电子电学计算软件,有电阻电容电感电压电流频率计算267444 ...
yjtyjt 下载中心专版
ARM9学习
我觉得ARM太难入门了,资料很多,可是难以理解。:Cry:...
225489720 ARM技术
关于ucweb for wince如何调用输入法的问题
在ucweb中点击输入框时会自动弹出系统自带的输入面板,有没有什么方法使ucweb显示自己开发的输入法?...
sinoxia 嵌入式系统
RT_THREAD定时器与系统时钟
定时器,是指在指定的时刻开始,经过一指定的时间后出发一个事件。定时器有硬件定时器和软件定时器之分: • 硬件定时器是芯片本身提供的定时功能。一般是由外部晶振提供给芯片输入时钟, ......
shilaike 嵌入式系统
计算机组成原理 DRAM问题 提问。
题目:说明1M×1位DRAM片子的刷新方法,刷新周期定为8ms。 解答:如果选择一个行地址进行刷新,刷新地址为A0——A8,因此这一行上的2048个存储元同时进行刷新,即在8ms内进行512个周期的刷新 ......
volcanohp 嵌入式系统
三极管保护电路分析!
430584有没有大佬可以帮忙分析一下,当SW和地短路时,这部分电路的工作原理 ...
CcKk 模拟电子

 
EEWorld订阅号

 
EEWorld服务号

 
汽车开发圈

 
机器人开发圈

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程 索引文件: 1150  902  1472  2408  516  23  38  44  37  52 

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区中关村大街18号B座15层1530室 电话:(010)82350740 邮编:100190

电子工程世界版权所有 京B2-20211791 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号 Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved