Embedded Power for
Business-Critical Continuity
LPQ170 Series
175 Watts
Total Power:
Input Voltage:
# of Outputs:
110 - 175 Watts
85-264 Vac
120-300 Vdc
Quad
Rev. 07.01.08
LPQ170 Series
1 of 4
Electrical Specifications
Special Features
• Active power factor correction
• IEC EN61000-3-2 compliance
• Adjustable outputs on 1, 3 & 4
Remote sense on main output
• Single wire current sharing
• Power fail and remote inhibit
• Built-in EMI filter
• Low output ripple
• Overvoltage protection
• Overload protection
• Thermal overload protection
• DC power good
• 5 V standby output
• Adjustable floating 4th output
• Optional cover (-C suffix)
Input
Input range:
Frequency:
Inrush current:
Efficiency:
EMI filter:
85-264 VAC; 120-300 VDC
47-67 Hz
38 A max, cold start @ 25°C
75% typical at full load
Meets FCC Class B conducted
CISPR 22 Class B conducted
EN55022 Class B conducted
VDE 0878 PT3 Class B conducted
0.99 typical
1.0 mA @ 50/60 Hz, 264 VAC input
Power Factor:
Safety ground
leakage current:
Output
Maximum power:
110 W convection (75 W with cover)
85 W convection - LPQ173
175 W with 30 CFM forced air
(130 W with cover - LPQ172)
3.3 - 5.5V on main; -12 - 15V on 3rd output
3.3 - 25 V on 4th output - LPQ172
3.3 - 5.5 V on 4th output - LPQ173
20 ms @175 W load at nominal line
Short circuit protection on all outputs. Case overload protected
@ 110-145% above peak rating
5 V @ 200 mA regulated ±5%
Adjustment range:
Safety
VDE
UL
CB
CSA
CE
NEMKO
0805/EN60950
(IEC950)
UL60950
Certificate and report
CSA 22.2-234 Level 3
Mark (LVD)
EN 60950/EMKO-TUE
Hold-up time:
Overload protection:
Overvoltage protection: Tracks outputs 1, 3 & 4; 15 to 35%
Standby output:
Embedded Power for
Business-Critical Continuity
Logic Control
AC power failure
Remote inhibit
Remote sense
DC - OK
TTL logic signal goes high 100 - 500 msec after V1 output; It
goes low at least 4 msec before loss of regulation
Requires contact closure to inhibit outputs
Compensates for 0.5 V lead drop min. Will operate without
remote sense connected. Reverse connection protected.
TTL logic signal goes high after main output is in regulation. It
goes low when there is a loss of regulation.
Rev. 07.01.08
LPQ170 Series
2 of 4
Environmental Specifications
Operating temperature: 0° to 50 °C ambient. Derate each output 2.5% per degree from
50° to 70 °C (except for -C version).
Storage temperature:
-40°C to +85°C
Temperature coefficient: ±0.4% per °C
Electromagnetic
Designed to meet IE61000-4, -2, -3, -4, -5, -6, -8, -11, Level 3
susceptibility:
Humidity:
Operating; non-condensing 5% to 95%
Vibration:
MTBF demonstrated:
Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at
four major resonances 0.75G peak 5Hz to 500Hz, operational
>550,000 hours at full load and 25°C ambient conditions
Ordering Information
Model
Number
LPQ172
Output
Voltage
5 V (3.3 - 5.5 V)
12 V
±3.3-25 V
LPQ173
5 V (3.3 - 5.5 V)
12 V
-12V (-12 -15 V)
5 V (3.3 - 5.5 V)
Maximum
Load with
Minimum Convection
Load
Cooling
0A
15 A
0A
0.5 A*
0A
0A
0A
0A
6A
1.5 A
2A
10 A
6A
.2 A
10 A
Maximum
Load with
30CFM
forced Air
30 A
8A
3A
5A
24 A
8A
3A
24 A
Ripple P/P
1 Regulation 2 (PARD)3
Peak Load
32 A
±2%
50 mV
10 A
3.5 A
5.5 A
26 A
10 A
3.5 A
26 A
±3%
±3%
±3%
±2%
±3%
±3%
±2%
120 mV
<1%
<50mV or 1%
50 mV
120 mV
<1%
50 mV
-12 V (-12 -15 V) 0 A
1. Peak current lasting <30 seconds with a maximum 10% duty cycle.
2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 μF in parallel with a 0.1 μF capacitor at rated line voltage and
load ranges.
4. 4th output adjustable 3.3-25 V factory set at 5 V.
5. *Minimum loads are required when output set below 5 Volts
6. Remote inhibit resets OVP latch
7. LPQ173-C has no convection rating.
Note: -C suffix added to the model number indicates cover option and is limited to 50 °C operation.
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±0.02”.
3. Specifications are for convection rating at factory settings unless
otherwise stated.
4. Mounting screw maximum insertion depth is 0.12”.
5. Warranty: 2 year
6. Weight: 2 lb / 0.91 kg
Embedded Power for
Business-Critical Continuity
Rev. 07.01.08
LPQ170 Series
3 of 4
Mechanical Drawing
LPQ172
TB2
1 2 3 4 5 6 7 8 9
1
5
Pin Assignments
Connector
LPQ172
N/C
5V Standby
N/C
V1 SWP
Common
+V1 sense
Sense common
Remote inhibit
DC power good
POK
+12 V
Common
-12 V
POK
Common (Float)
COMMON
+5 V (3.3V to 5.5V)
N/C
GROUND
LINE
NEUTRAL
LPQ173
V4 SWP
5 V Standby
+V4 Sense
V1 SWP
Common
+V1 sense
Sense common
Remote inhibit
DC power good
POK
+12V
Common
-12V
POK
N/C
COMMON
+5V (3.3V to 5.5V)
+5V (3.3V to 5.5V)
GROUND
LINE
NEUTRAL
LPQ173
SK2
SK3
TB1
SK1 PIN 1
V4
V1
P251
SK1
TB4 TB2
SK3
P252
PIN 2
PIN 3
PIN 4
PIN 5
PIN 6
PIN 7
1.50
(38.1)
0.75
(19.0)
0.95
(24.0)
0.55
(14.0)
6
10
SK2
SK1
V2
V2
COM
COM
N/C
N/C
POK
V3
TB3 TB1
PIN 8
PIN 9
PIN 10
SK2 PIN 1,2
PIN 3,4,5
PIN 6
PIN 7
PIN 8
PIN 9
SK3 TB-1, 3
TB-2
TB-4
SK4 PIN 1
6.61
(168.0)
7.4
(188.0)
8.5
(216.0)
SK4
1
3
5
COM
+3.3 V to +25 V (Float) N/C
PIN 3
PIN 5
V4 (3V3-25V)
V1 (3V3-5V7)
Mating Connectors
(SK4) AC Input:
V3 O/P ADJ.
V3 (-12V TO -15V7)
Molex 09-50-8051 (USA)
Molex 09-91-0500 (UK)
PINS: 08-58-0111
Molex series 19141-0058/0063
V1 O/P ADJ.
V4 O/P ADJ.
F
C
(SK3) Main output:
SK2
SK1
4.25
(108.0)
SK3
(SK2) Aux DC Output/Power fail:
Molex 09-50-8091 (USA)
Molex 09-91-0900 (UK)
PINS: 08-58-0111
0.88
(22.2)
(SK1) Control Signals:
Molex 90142-0010 (USA)
PINS: 90119-2110 or
Amp: 87977-3
PINS: 87309-8
Astec connector kit #70-841-015, includes all of above
1.07
(27.2)
2.11
(53.5)
M3(8 PLACES)
2.50
(63.5)
#6-32(8 PLACES)
Embedded Power for
Business-Critical Continuity
Americas
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 (760) 930 4600
Facsimile: +1 (760) 930 0698
Rev. 07.01.08
LPQ170 Series
4 of 4
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Asia (HK)
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
www.powerconversion.com
techsupport.embeddedpower
@emerson.com
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
Embedded Computing
Embedded Power
Monitoring
Outside Plant
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
EmersonNetworkPower. com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2008 Emerson Electric Co.