power, low-dropout voltage references offer high initial
accuracy and very low temperature coefficient through
a proprietary curvature-correction circuit and laser-
trimmed precision thin-film resistors.
These series-mode bandgap references draw a maxi-
mum of only 35µA quiescent supply current, making
them ideal for battery-powered instruments. They offer
a supply current that is virtually immune to input volt-
age variations. Load-regulation specifications are
guaranteed for source and sink currents up to 500µA.
These devices are internally compensated, making
them ideal for applications that require fast settling,
and are stable with capacitive loads up to 2.2nF.
♦
±2mV (max) Initial Accuracy
♦
5ppm/°C (max) Temperature Coefficient
♦
35µA (max) Supply Current
♦
100mV Dropout at 500µA Load Current
♦
0.12µV/µA Load Regulation
♦
8µV/V Line Regulation
Features
Applications
Hand-Held Instruments
Analog-to-Digital and Digital-to-Analog Converters
Industrial Process Control
Precision 3V/5V Systems
Hard-Disk Drives
Selector Guide
PART
MAX6190A
MAX6190B
MAX6190C
MAX6191A
MAX6191B
MAX6191C
MAX6192A
MAX6192B
MAX6192C
MAX6193A
MAX6193B
MAX6193C
MAX6198A
MAX6198B
MAX6198C
MAX6194A
MAX6194B
MAX6194C
MAX6195A
MAX6195B
MAX6195C
OUTPUT
VOLTAGE
(V)
1.250
1.250
1.250
2.048
2.048
2.048
2.500
2.500
2.500
3.000
3.000
3.000
4.096
4.096
4.096
4.500
4.500
4.500
5.000
5.000
5.000
INITIAL
ACCURACY
(mV)
±2
±4
±6
±2
±5
±10
±2
±5
±10
±2
±5
±10
±2
±5
±10
±2
±5
±10
±2
±5
±10
TEMPERATURE
COEFFICIENT
(ppm/°C)
<5
<10
<25
<5
<10
<25
<5
<10
<25
<5
<10
<25
<5
<10
<25
<5
<10
<25
<5
<10
<25
Ordering Information
PART
MAX6190AESA+
MAX6190BESA+
MAX6190CESA+
MAX6191AESA+
MAX6191BESA+
MAX6191CESA+
MAX6192AESA+
MAX6192BESA+
TEMP RANGE
-40°C to +85°C
-40°C to +85°C
-40°C to +85°C
-40°C to +85°C
-40°C to +85°C
-40°C to +85°C
-40°C to +85°C
-40°C to +85°C
PIN-PACKAGE
8 SO
8 SO
8 SO
8 SO
8 SO
8 SO
8 SO
8 SO
MAX6192CESA+
-40°C to +85°C
8 SO
Ordering Information continued at end of data sheet.
+Denotes
a lead(Pb)-free /RoHS-compliant package.
Pin Configuration
TOP VIEW
+
N.C. 1
IN 2
N.C.
3
8
N.C.
N.C.
OUT
N.C.
MAX6190–
MAX6195
MAX6198
7
6
5
GND 4
Typical Operating Circuit appears at end of data sheet.
SO
For pricing, delivery, and ordering information, please contact Maxim Direct
at 1-888-629-4642, or visit Maxim’s website at www.maximintegrated.com.
19-1408; Rev 3; 4/10
MAX6190–MAX6195/MAX6198
Precision, Micropower,
Low-Dropout Voltage References
ABSOLUTE MAXIMUM RATINGS
Voltages Referenced to GND
IN ......................................................................-0.3V to +13.5V
OUT ..........................................................-0.3V to (V
IN
+ 0.3V)
Output Short Circuit to GND or IN (V
IN
< 6V) ............Continuous
Output Short Circuit to GND or IN (V
IN
≥
6V) .........................60s
Continuous Power Dissipation (T
A
= +70°C)
8-Pin SO (derate 5.88mW/°C above +70°C)................471mW
Operating Temperature Range ...........................-40°C to +85°C
Junction Temperature ......................................................+150°C
Storage Temperature Range .............................-65°C to +150°C
Lead Temperature (soldering, 10s) .................................+300°C
Soldering Temperature (reflow) .......................................+260°C
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
For healthcare professionals, accurate diagnosis and treatment are crucial for a clear picture of a person's health. However, healthcare professionals often rely on tests at medical facilities, cli...[详细]
1. 内容简介 在2015年,苹果新一代的MacBook和Apple Watch皆搭载压力触控感应技术,它被Apple称为Force Touch,用户每次按下触控板之后除了可以在萤幕看见视觉回馈,它同时能够分辨出用户点按的力度强弱来做出一系列的相关操控与应用。而本文将介绍以HY16F184内建高精密Sigma-delta 24 Bit ADC搭配Uneo Force Sensor来实现一...[详细]