1000V UL Flex Motor VFD, (3) 3/0 AWG (19x7x19) TC+Grd, XLPE/PVC, Dual
Cu Tape Shld, TC-ER
Product Description
Three 3/0 AWG stranded (19x7x19) tinned copper circuit conductors plus three symmetrical ground wires, cross-linked polyethylene insulation, two helical
copper tape shields (100% Coverage), PVC jacket.
Technical Specifications
Product Overview
Suitable Applications:
AC Motor drives, VFD, Variable Frequency drives
Physical Characteristics (Overall)
Conductor
Element
AWG Stranding
3/0
Ground Wire 4
Conductor Count:
Conductor Size:
Insulation
Material
Nominal Wall Thickness
7x19x19
7x19x25
Material
No. of Conductors
TC - Tinned Copper 3
BC - Bare Copper
3
3/0
1
XLP - Cross Linked Polyolefin 0.057 in
Color Chart
Number
1
2
3
Color
Black and Numbered 1
Black and Numbered 2
Black and Numbered 3
Outer Shield Material
Type Description Layer
Tape .002"
Tape .002"
1
2
Material
Coverage [%]
Spiral Copper 100 %
Spiral Copper 100 %
Outer Jacket Material
Material
Nominal Diameter Nominal Wall Thickness
0.083 in
PVC - Polyvinyl Chloride 1.516 in
Construction and Dimensions
Stranding
Lay Length
Y mm
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR
0.063 Ohm/1000ft
Capacitance
Nom. Capacitance Conductor to Conductor Nom. Capacitance Conductor to Other Conductor to Shield
48 pF/ft
Shielding:
Inductance
Nominal Inductance
0.138 µH/ft
Current
Max. Recommended Current [A]
225 Amps per conductor @ 30°C
Voltage
Description
UL Voltage Rating Voltage Rating [V]
1000 V RMS
86 pF/ft
Foil(s) or Copper Tape(s)
CSA AWM I/II A/B 1000 V RMS
600 V RMS
Temperature Range
UL Temp Rating:
Operating Temp Range:
Wet Temp Range:
Dry Temp Range:
90°C
-40°C To +90°C
-40°C To +90 °C
-40°C To +90 °C
Mechanical Characteristics
Oil Resistance:
Bulk Cable Weight:
Max Recommended Pulling Tension:
Min Bend Radius/Minor Axis:
Yes
2538 lbs/1000ft
5025 lbs
15.2 in
Standards
NEC Articles:
NEC/(UL) Specification:
CEC/C(UL) Specification:
CSA AWM Specification:
PMSHA Specification:
Other Specification:
336 - ER
TC-ER, WTTC, XHHW-2
TC
AWM I/II A/B
P-07-KA070003
1000V UL Flexible Motor Supply Cable
Applicable Environmental and Other Programs
EU Directive 2000/53/EC (ELV):
EU Directive 2003/96/EC (BFR):
EU Directive 2011/65/EU (ROHS II):
EU Directive 2012/19/EU (WEEE):
EU Directive 2015/863/EU:
EU Directive Compliance:
EU CE Mark:
Yes
Yes
Yes
Yes
Yes
EU Directive 2003/11/EC (BFR)
Yes
EU RoHS Compliance Date (yyyy-mm-dd): 2005-11-09
CA Prop 65 (CJ for Wire & Cable):
MII Order #39 (China RoHS):
Yes
Yes
Suitability
Suitability - Burial:
Suitability - Indoor:
Suitability - Oil Resistance:
Suitability - Outdoor:
Suitability - Sunlight Resistance:
Yes
Yes
Yes
Yes
Yes
Flammability, LS0H, Toxicity Testing
C(UL) Flammability:
UL Flammability:
RW90, FT4
UL1685 UL Loading
CSA Flammability:
IEEE Flammability:
UL Voltage Rating:
FT4
1202, 383
1000V RMS
Plenum/Non-Plenum
Plenum (Y/N):
No
Part Number
Variants
Item #
Color
Footnote
29531 0101000 BLACK C 9
29531 0102000 BLACK C Z
Footnote:
Footnote:
Footnote:
C - CRATE REEL PUT-UP.
9 - FINAL PUT-UP LENGTH MAY VARY (+ OR -) 5% FROM LENGTH SHOWN.
Z - FINAL PUT-UP MAY VARY (= OR -) 10% FOR SPOOLS OR REELS AND (+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without
notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages
(including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief
at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product
Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and
regulations based on their individual usage of the product.
2008年7月9日,欧司朗光电半导体率先推出发光二极管光线数据文件的互联网访问平台,是全球第一家提供该类互联网资源的 LED 制造商。这些光线文件不仅描述 LED 光线的发射模式,而且还包含发射点坐标、发射方向、光线强度和波长等信息。欧司朗的互联网信息资源涵盖包括红外发光二极管 (IRED) 在内的几乎所有 LED 产品组合。透过这平台,客户们不论白天或黑夜,随时都可以获取最新的数据,这无疑为他...[详细]