UBBP01
Technical Datasheet
Technical Specifications
Part No.
Voltage Range
Average Voltage
Capacity
Max. Discharge
PTC
Energy
Energy Density
Weight
Cycle Life
Memory
Operating Temperature
Storage Temperature
Self-Discharge
Exterior/Housing
Terminals/Connector
UBBP01
3.0 to 4.2V
3.7V
1.8Ah @ C/5 Rate @ 23°C±2°C
1.8A continuous
Rated for 2.1A Hold Current @ 25°C
6.7Wh
146Wh/kg, 317Wh/l
46g
> 500 cycles @ C/5 to 80% of inital capacity
No Memory Effect
-20°C to 60°C
-20°C to 45°C
< 10% per month
PVC Shrink Wrap
24 AWG Wire with:
JST Connector PHR02: Red (+), Black (-)
Contact for housing is JST SPH-002T-P0.5
UL Recognized Component
IEC62133 Certified
Material Safety Datasheet - MSDS041
Safety Guide UBM-5112
DK-25033-UL
Excepted from regulations for packages with
gross mass of 10kg or less (see note)
Over Voltage Limit: 4.275±0.03V
Under Voltage Limit: 2.3±0.03V
Over Current Protection: 1.8 - 3.0A
Recommended charge rate is 900mA to 4.2V
in a temperature range of 0°C to 45°C. Hold at
4.2V until current declines to 180mA. Maximum
charge rate is 1.8A @ 20°C±5°C.
Store at 50% capacity. Every 4-6 months, cycle
(full charge / full discharge) and charge the
battery back to 50% before placing it back into
storage.
To prevent injury or burns, do not disassemble,
crush, short circuit, overheat or dispose of in fire.
A complete description of transportation
regulations, lithium weights and transportation
classifications is available on the Ultralife website.
Features
•
•
•
•
•
•
Common sizes
Thin
High energy density
Wide operating temperature range
Lightweight
Can be assembled into packs
Safety
Applications
•
Portable electronics
•
Medical equipment
•
Tracking applications
CB ID
Transportation
Protection
Optional Accessories
•
UCH0036-S: Wall Wart charger (U.S.)
•
UCH0036-I: Wall Wart charger
(International)
Charging
Storage
Warning
Note
UBBP01
Newark, New York | 315-332-7100 | Fax: 315-331-7800
©2014 Ultralife Corporation • www.ultralifecorp.com • All information is subject to change without notice.
The information contained herein is for reference only and does not constitute a warranty of performance. •
30 OCT 14 UBM-5154 Rev: K
Dimensions
5.8
Performance Graphs
Charge Characteristics @ 23˚C
4.2V Constant Voltage Charge with 0.9A Current Limit
4.4
4.2
Voltage (V)
Constant Current Discharge to 3V @ -20˚C
4.2
2.5
Load Voltage (V)
Voltage
Capacity
4.0
Capacity (Ah)
4.0
3.8
3.6
3.4
3.2
3.0
0.0
0.5
1.0
1.5
Time (Hours)
2.0
2.5
3.0
Current
2.0
1.5
1.0
0.5
0.0
3.8
3.6
3.4
3.2
3.0
0
1
2
3
Load Time (Hours)
4
0.2C
0.5C
1.0C
5
Constant Current Discharge to 3V @ 23˚C
Constant Current Discharge to 3V @ 60˚C
0.2C
0.5C
1.0C
4.2
4.0
Load Voltage (V)
4.2
Load Voltage (V)
4.0
3.8
3.6
3.4
3.2
3.0
0
1
2
3
4
5
3.8
3.6
3.4
3.2
0.2C
0.5C
1.0C
6
3.0
0
1
2
3
4
5
6
Load Time (Hours)
Load Time (Hours)
UBBP01
Newark, New York | 315-332-7100 | Fax: 315-331-7800
©2014 Ultralife Corporation • www.ultralifecorp.com • All information is subject to change without notice.
The information contained herein is for reference only and does not constitute a warranty of performance. •
30 OCT 14 UBM-5154 Rev: K