Premium protection for essential network workstations, telecom systems, point-of-sale equipment and audio/video systems, the ISOBAR6 Isobar® 6-Outlet
Surge Protector features a network-grade surge protection rating of 3300 joules to defend your sensitive electronics against even the strongest surges and
spikes. In fact, Tripp Lite will repair or replace any connected equipment damaged by surges, including direct lightning strikes, up to $50,000 for life (valid in the
U.S., Canada and Puerto Rico only).
The ISOBAR6 features six NEMA 5-15R outlets, which are arranged in three exclusive isolated filter banks that prevent equipment connected to one bank
from interacting with equipment connected to the other. These internal barriers also prevent disruptive line noise from causing A/V distortion, computer
lock-ups, data errors and similar problems. Large toroidal chokes, ferrite rod-core inductors, HF/VHF capacitors and multiple layers of metal oxide varistors
remove EMI/RFI interference and prevent system crashes, reboots and performance problems.
Because residential power outlets have three wires—hot line (H), neutral (N) and ground (G)—the ISOBAR6 protects all three, covering two protection modes:
full normal mode (H-N) and common mode (N-G/H-G).
Included safety covers protect against dust while blocking accidental contact with unused outlets. An integrated 12A circuit breaker protects all outlets and
shuts down connected equipment in the event of an overload. A lighted on/off switch provides one-touch control over connected component. Diagnostic LEDs
show power, protection and line fault status at a glance. A six-foot AC power cord with right-angle 5-15P plug reaches nearby outlets and allows furniture to be
placed flush against the wall. An all-metal stands up to rugged environments.
Features
Network-Grade 3300-Joule Surge Protection for Home or Office Electronics
Protects your essential network workstations, telecom systems, point-of-sale equipment, audio/video systems and other expensive electronics against
surges and spikes
Recommended for home, corporate, retail, telecom and industrial applications requiring AC line protection
Full normal mode (H-N) and common mode (N-G/H-G) line surge suppression
1/4
Exceeds IEEE 587 Category A and B surge suppression specifications
6 Outlets Accept Wide Range of Electronic Devices
6 NEMA 5-15R AC outlets accept most computer equipment, electronics, appliances and power tools
Outlets accommodate up to 3 bulky transformers without blocking other outlets
Included safety covers block accidental contact with unused outlets
Isolated Filter Banks Provide Extra Protection
Outlets arranged in 3 exclusive isolated filter banks to limit noise interaction among connected equipment
Block disruptive EMI/RFI line noise up to 80 dB that can cause equipment damage or data loss
Combine large toroidal chokes, ferrite rod-core inductors, HF/VHF capacitors and metal oxide varistors to block interference
Premium Safety Features
Lighted on/off switch provides one-touch control over connected equipment
Automatic shutoff cuts power to outlets when protection circuit has been compromised
Diagnostic LEDs confirm power, protection and line fault status at a glance
Conforms to current UL 1449 3rd Edition safety standards
Fits Effortlessly Into Your Workstation
6 ft. AC power cord reaches nearby outlets
Space-saving right-angle NEMA 5-15P plug allows furniture and equipment to move flush against the wall
Keyhole slots on bottom panel provide convenient wall or desk mounting options
Metal housing designed for long life
Backed by Tripp Lite’s Ultimate Lifetime Insurance
$50,000 Ultimate Lifetime Insurance covers any connected components damaged by power surge (U.S., Canada and Puerto Rico only)
Specifications
OUTPUT
Frequency Compatibility
Output Receptacles
Output (Watts)
Circuit Breaker (amps)
Transformer Accommodation
Right-Angle Outlets
50 / 60 Hz
(6) 5-15R
1440
12
Supports up to 4 large transformer plug accessories without covering remaining outlets
No
INPUT
Nominal Input Voltage(s) Supported
Recommended Electrical Service
Input Connection Type
120V AC
120V (110-125V)
NEMA 5-15P input plug
2/4
Input Plug Features
Input Cord Length (ft.)
Input Cord Length (m)
Voltage Compatibility (VAC)
Maximum Surge Amps
Right-Angle Plug
Space-saving right angle input plug
6
1.83
120
135000
Yes
USER INTERFACE, ALERTS & CONTROLS
Switches
Combination AC circuit breaker and two position red illuminated on/off power switch
SURGE / NOISE SUPPRESSION
AC Suppression Joule Rating
AC Suppression Response Time
Protection Modes
Clamping Voltage (RMS)
AC Suppression Surge Current
Rating
AC Suppression Components Used
Safe Thermal Fusing
UL1449 Let Through Rating
IEEE587 Cat. A Ringwave
Let-Through
EMI / RFI Filtering
Isolated Filter Banks
Immunity
3330
NM = 0 ns. CM = <1 ns
Includes full normal mode (H-N) and common mode (N-G / H-G) line surge suppression
140
97,000 amps (36,000 NM / 61,000 CM)
Metal oxide varistors, toroidal balanced chokes, ferrite rod-core inductors and VHF capacitors.
Prevents unsafe conditions during extreme extended over-voltages and catastrophic occurrences
330V
Less than 35 volts
40-80 dB
Unique isolated filter bank design offers additional filtering between each duplex pair of outlets on the strip to
prevent electrical noise interference between connected loads. Includes 3 filter banks.
Conforms to IEE 587 / ANSI C62.41
DATALINE SURGE SUPPRESSION
Telephone/DSL Protection
Cable (Coax) Protection
Network (Ethernet) Protection
No
No
No
PHYSICAL
Shipping Dimensions (hwd / in.)
Shipping Dimensions (hwd / cm)
Shipping Weight (lbs.)
Shipping Weight (kg)
Unit Dimensions (hwd / in.)
11.5 x 7 x 3
29.21 x 17.78 x 7.62
2.9
1.32
2.5 x 6 x 3.5
3/4
Unit Dimensions (hwd / cm)
Unit Weight (lbs.)
Unit Weight (kg)
Material of Construction
Integrated Keyhole Mounting Tabs
Housing Color
Receptacle Color
Color (AC Line Cord)
Outlets Measurement (Center to
Center)
Keyhole Slot Mounting
Measurement (Center to Center)
6.35 x 15.24 x 8.89
2.4
1.09
Metal
Metal end caps are fitted with keyhole mounting tabs for wallmount installation
Light Gray
Black
Light Gray
Distance between horizontal outlets = 39.45mm; Distance between vertical outlets = 39.30mm
Distance between horizontal tabs = 171.34mm; Distance between vertical tabs = 58.17mm
not imply any affiliation with or endorsement by them. Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice.
Tripp Lite uses primary and third-party agencies to test its products for compliance with standards. See a list of Tripp Lite's testing agencies:
Logic analyzers are widely used tools in digital design verification and debugging. They can verify the proper functioning of digital circuits and help users identify and troubleshoot faults. They ...[详细]