SmartPro 120V 1.5kVA 1.35kW Line-Interactive
Sine Wave UPS, 2U, Network Card Options, LCD,
USB, DB9, 8 Outlets
MODEL NUMBER:
SMART1500RM2U
Highlights
q
Corrects under- and
overvoltages from 83V to 147V
q
8 NEMA 5-15R outlets—4
switchable via network interface
q
Network power management
and control capability
q
Interactive LCD monitoring
screen
q
13 min. runtime at half load; 4.5
min. at full load
Package Includes
q
SMART1500RM2U SmartPro
120V 1.5kVA 1.35kW Line-
Interactive Sine Wave UPS
q
USB cable
DB9 cable
EPO cable
Mounting hardware
Owner’s manual
Description
The SMART1500RM2U SmartPro 120V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS provides battery
backup and AC power protection against blackouts, brownouts, power surges and line noise that can
damage electronics or destroy data. Ideal for backing up servers and network storage devices, the
SMART1500RM2U switches to battery mode in milliseconds to keep your connected equipment running
long enough to save files and shut down safely with no data loss.
q
q
q
q
Featuring eight NEMA 5-15R outlets (four switchable) and a 10-foot power cord with 120V NEMA 5-15P
input, the SMART1500RM2U has an internal battery that provides 13 minutes of support at half load and
4.5 minutes at full load. A front-panel LCD screen lets you monitor important data, such as load level,
voltage, battery charge and estimated runtimes.
Automatic voltage regulation (AVR) maintains 120V nominal output over an input range of 83V to 147V
without using battery power. EMI/RFI noise filtering improves your equipment’s performance and prevents
damage. A 570-joule surge suppression rating protects your equipment from harmful power surges. With
Tripp Lite’s PowerAlert® software (available via free download), the SMART1500RM2U enables safe
unattended system shutdown and file saves in case of a prolonged power failure.
Features
Protects Mission-Critical Rack-Mounted Equipment
q
Provides fully regulated sine wave AC output for servers, network storage devices and telecom
hardware
q
Audible alarm signals loss of utility power, overload, low battery and fault conditions
8 NEMA 5-15R outlets
q
1/6
q
10 ft. power cord with 120V NEMA 5-15P input
0.9 power factor rating
570-joule surge suppression rating
q
q
Reliable Battery Backup
q
Supports half load up to 13 min. and full load up to 4.5 min.
Internal batteries designed for hot-swap field replacement
95% line-power efficiency rating saves money in energy costs
q
q
2 Load Banks with Switchable Outlets
q
Can control 4 outlets remotely to reboot equipment or shed nonessential loads
Automatic Voltage Regulation (AVR)
q
Maintains 120V nominal output over input range of 83V–147V without using battery power
EMI/RFI Line Noise Filtering
q
Removes electromagnetic and radio frequency interference that can disrupt or damage equipment’s
performance
Interactive LCD Screen
q
Front-panel LCD signals operating mode, load level, voltage, battery charge and estimated runtimes
Rotates for easy viewing in rack-mount or tower configurations
q
Network Management Cards
q
Compatible with Tripp Lite UPS management card options TLNETCARD, WEBCARDLX,
SNMPWEBCARD and RELAYIOCARD
Communications Ports
q
USB & Serial ports enable data-saving unattended shutdown when used with Tripp Lite's PowerAlert
software, available via FREE download from www.tripplite.com/poweralert
q
EPO port supports emergency shutdown in large facilities
Versatile Installation Options
q
Hardware included for 4-post mounting in 2U of EIA-standard 19 in. rack
Mounts on wall or 2-post rack with optional 2POSTRMKITWM accessory
Mounts in upright tower position with optional 2-9USTAND accessory
q
q
Specifications
2/6
MODEL TEXT
Key Benefit
Protects connected mission-critical equipment against damage, downtime and data loss due to blackouts,
brownouts, power surges and line noise. Ideal solution for data centers, VoIP systems and network closets.
OUTPUT
Output Volt Amp Capacity (VA)
Output kVA Capacity (kVA)
Output Watt Capacity (Watts)
Output kW Capacity (kW)
Power Factor
Nominal Output Voltage(s)
Supported
Nominal Voltage Details
Frequency Compatibility
Output Voltage Regulation (Line
Mode)
Output Voltage Regulation (Battery
Mode)
Output Receptacles
Load Management Receptacles
Output AC Waveform (AC Mode)
Output AC Waveform (Battery
Mode)
1500
1.5
1350
1.35
0.9
110V; 115V; 120V
120v nominal output in battery mode
60 Hz
-21%, +8%
+/- 5%
(8) 5-15R
Two switchable two-outlet 5-15R load banks
Sine wave
Pure Sine wave
INPUT
Rated input current (Maximum Load)
Nominal Input Voltage(s) Supported
UPS Input Connection Type
Input Circuit Breakers
UPS Input Cord Length (ft.)
UPS Input Cord Length (m)
Recommended Electrical Service
Input Phase
12A
120V AC
5-15P
15A
10
3.0
15A 120V
Single-Phase
BATTERY
Full Load Runtime (min.)
Half Load Runtime (min.)
4.5 min. (1350w)
13 min. (675w)
3/6
DC System Voltage (VDC)
Battery Recharge Rate (Included
Batteries)
Internal UPS Replacement Battery
Cartridge
Battery Access
Battery Replacement Description
Expandable Runtime
36
Less than 4.5 hours from 10% to 90% (typical, full load discharge)
RBC93-2U
Front panel battery access door
Hot-swappable, user replaceable batteries
No
VOLTAGE REGULATION
Voltage Regulation Description
Overvoltage Correction
Undervoltage Correction
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 147
Input voltages between 128 and 147 are reduced by 12%
Input voltages between 83 and 107 are boosted by 14%
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display
Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data,
plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for
detailed LCD configuration and monitoring options)
3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions
Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option
available
Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown
conditions
Switches
Alarm Cancel Operation
Audible Alarm
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating
UPS AC Suppression Response
Time
EMI / RFI AC Noise Suppression
570
Instantaneous
Yes
PHYSICAL
Included Mounting Accessory
Description
Installation Form Factors Supported
with Optional Accessories
Primary Form Factor
UPS Power Module Dimensions
(hwd, in.)
UPS Power Module Dimensions
(hwd, cm)
Rack Height (U Spaces)
4 post rackmount installation accessories included
2 post rackmount (2POSTRMKITWM); Wallmount (2POSTRMKITWM); Tower (2-9USTAND)
Rackmount
3.45 x 17.3 x 13.45
8.76 x 43.94 x 34.16
2
4/6
Minimum Required Rack Depth
(inches)
Minimum Required Rack Depth (cm)
UPS Power Module Weight (lbs.)
UPS Power Module Weight (kg)
UPS Shipping Dimensions (hwd /
in.)
UPS Shipping Dimensions (hwd /
cm)
Shipping Weight (lbs.)
Shipping Weight (kg)
Cooling Method
UPS Housing Material
Minimum Required Rack Depth
(mm)
Primary UPS Height (mm)
Primary UPS Width (mm)
Primary UPS Depth (mm)
Shipping Height (mm)
Shipping Width (mm)
Shipping Depth (mm)
16.5
41.91
46.5
21.09
8.5 x 23.4 x 19.9
21.59 x 59.44 x 50.55
57.6
26.2
Fan
Steel
419
88
439
342
216
594
505
ENVIRONMENTAL
Operating Temperature Range
Storage Temperature Range
Relative Humidity
AC Mode BTU / Hr. (Full Load)
Battery Mode BTU / Hr. (Full Load)
AC Mode Efficiency Rating (100%
Load)
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
0 to 95%, non-condensing
267
1012
95%
COMMUNICATIONS
Communications Interface
Network Management Cards
Network Monitoring Port Description
PowerAlert Software
Communications Cable
USB; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface
SNMPWEBCARD; TLNETCARD; WEBCARDLX; RELAYIOCARD
Supports detailed monitoring of UPS and site power conditions
For local monitoring via the UPS’s built-in communication ports , download PowerAlert Local software at
http://www.tripplite.com/poweralert
USB and DB9 cabling included
5/6