500W True Sine Wave DC-AC Inverter with MPPT Solar Charger
ISI-501
series
■
Features
True sine wave output (THD<3%)
High surge power up to 1000W
High efficiency up to 88%
High frequency design
Thermostatically controlled cooling fan
Protections: Bat. low alarm / Bat. low shutdown / Over voltage
/ Over temp. / Output short / Input polarity reverse / Overload
Built-in 500W MPPT solar charger, MPPT efficiency:98%(Typ.)
Built-in remote ON-OFF control
Built-in battery low relay contact
LED indicator for operation status and battery capacity
3 years warranty
■
Applications
Home appliance
Power tools
Portable equipment
Yacht
Vehicle
■
Description
ISI-501 series integrates a DC/AC True Sine Wave Inverter and a MPPT charger. This series is a high
performance true sine wave DC/AC inverter which converts the DC electricity from a system consisting
of batteries and solar panels. ISI-501 is not only a high frequency designed inverter but also fully digitally
controlled by an advanced microprocessor. With true sine wave output, ISI-501 series can provide 500W
continuously, 550W for 60 seconds, and 1000W for 30 AC-cycles. This series incorporates a MPPT solar
charger, including the constant current and constant voltage charging
characteristics.
■
Model Encoding
ISI - 501 - 112 - A
12:12VDC
Bat. Voltage 24:24VDC
48:48VDC
1:110VAC
AC Output Voltage
2:230VAC
Output Wattage
Series Name
{
AC Output
Receptacle
{
{
A :TYPE A
B :TYPE B
C :TYPE C
D :TYPE D
E :TYPE E
F :TYPE F
U :TYPE U
OUTLET
OUTLET
OUTLET
OUTLET
OUTLET
OUTLET
OUTLET
File Name:ISI-501-SPEC 2018-01-15
500W True Sine Wave DC-AC Inverter with MPPT Solar Charger
AC Output Receptacles(Optional)
ISI-501
series
Receptacle type
TYPE-A
Standard
TYPE-B
Standard
EUROPE
TYPE-C
Optional
AUSTRALIA
TYPE-D
Optional
U.K
TYPE-E
Optional
JAPAN
TYPE-F
Optional
GFCI
TYPE-U
Optional
Country
Certificate
USA
UNIVERSAL
Non
SPECIFICATION
MODEL
RATED POWER
ISI-501-112□
450W
ISI-501-124□
500W
ISI-501-148□
ISI-501-212□
450W
ISI-501-224□
500W
ISI-501-248□
MAXIMUM OUTPUT POWER (Typ.)
550W for 60 sec. / surge power 1000W for 30 cycles (112, 212 models : 495W for 60 sec. / surge power 900W for 30 cycles)
AC VOLTAGE
OUTPUT
FREQUENCY
Factory setting set at 110VAC
100 / 110 / 115 / 120VAC selectable by setting button S.W
Factory setting set at 110VAC
Factory setting set at 230VAC
200 / 220 / 230 / 240VAC selectable by setting button S.W
Factory setting set at 230VAC
60
±
0.1Hz
50/60Hz selectable by setting button S.W
50
±
0.1Hz
50/60Hz selectable by setting button S.W
INVERTER
SECTION
INPUT
WAVEFORM
Note.1
True sine wave (THD<3%)
AC REGULATION (Typ.)
±
3%
FRONT PANEL INDICATOR
Fault and operation status, Charger status, Battery capacity
12V
24V
48V
BAT. VOLTAGE
VOLTAGE RANGE
Note.3,5
10.5 ~ 15VDC
DC CURRENT (Typ.)
Note.7
50A
NO LOAD CURRENT DRAW (Typ.)
1.25A
12V
10.5 ~ 15VDC
50A
1.25A
86%
24V
21 ~ 30VDC
30A
0.63A
88%
48V
42 ~ 60VDC
15A
0.32A
88%
21 ~ 30VDC
30A
0.63A
42 ~ 60VDC
15A
0.32A
OFF MODE CURRENT DRAW (Typ.)
≦1mA
87%
87%
Note.2
85%
EFFICIENCY (Typ.)
Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
OUTPUT SHORT
Shut down o/p voltage, re-power on to recover
OUTPUT
110% load for 60 sec.
PROTECTION OVER LOAD (Typ.)
Protection type : Shut down o/p voltage, re-power on to recover
CHARGER CURRENT (Typ.)
30A
17A
8.5A
Open & sealed Lead Acid
BATTERY TYPE
BATTERY SECTION
FUSE
30A
40A*2
11.3V
10.5V
17A
40A*1
22.5V
21V
8.5A
20A*2
45V
42V
40A*2
40A*1
22.5V
BAT. LOW ALARM
Note.3
11.3V
10.5V
21V
BAT. LOW SHUTDOWN
Note.3
By internal fuse open
REVERSE POLARITY
MPPT CHARGER EFFICIENCY (
Typ.
)
98%
OPEN CIRCUIT VOLTAGE RANGE
35 ~ 50V
25 ~ 50V
MPPT RANGE
SOLAR INPUT CURRENT (Typ.)
11A
20A*1
45V
42V
MPPT / SOLAR
SECTION
45 ~ 90V
35 ~ 90V
7A
90 ~ 160V
70 ~ 160V
4.5A
35 ~ 50V
25 ~ 50V
11A
45 ~ 90V
35 ~ 90V
7A
90 ~ 160V
70 ~ 160V
4.5A
SOLAR INPUT POWER (Typ.)
WORKING TEMP.
500W
20% ~ 90% RH non-condensing
-30 ~ +70
℃
/ -22 ~ +158 F, 10 ~ 95% RH non-condensing
o
Note.4
-20 ~ +40
℃
@ 100% load ; 60
℃
@ 50% load
ENVIRONMENT
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
VIBRATION
SAFETY STANDARDS
GENERAL
SECTION
10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
EAC TP TC 004 approved
None
Bat I/P - AC O/P:3.0KVAC
EN60950-1 (LVD)
AC O/P - FG:1.5KVAC
Compliance to EN55032 class B,
EAC TP TC 020
Compliance to EN61000-4-2,3,8,
EAC TP TC 020
SAFETY
&
EMC
LVD
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
MTBF
DIMENSION
PACKING
Bat I/P - AC O/P, Bat I/P - FG, AC O/P - FG: 100M ohms / 500VDC / 25
℃
/ 70% RH
Compliance to FCC part 15 class B,
EAC TP TC 020
Compliance to
EAC TP TC 020
57.8K hrs min.
MIL-HDBK-217F (25
℃
)
205*158*67mm (L*W*H)
2.35Kg; 6pcs/15.1Kg/1.55CUFT
OTHERS
NOTE
1.THD is tested by rated power, linear load at 13V,26V,52V input voltage.
2.Efficiency is tested by 350W, linear load at 13V,26V,52V input voltage.
3.The tolerance of each voltage value by models
is : 112/212
→±
0.5V ; 124/224
→±
1V ; 148/248
→±
2V.
4.Output derating capacity referenced by curve 1.
5.Input derating capacity referenced by curve 2.
6.All parameters not specified above are measured at rated load, 25
℃
of ambient temperature and set to factory setting.
7.DC current is tested by 500W, linear load at 12V,24V,48V input voltage.
8.The ambient temperature derating of 3.5
℃
/1000m with fanless models and of 5
℃
/1000m with fan models for operating altitude higher than
2000m(6500ft).
File Name:ISI-501-SPEC 2018-01-15