Sensor/Actuator cable, 5-position, PVC, black RAL 9005, Plug straight M12, A-coded, on Socket straight M12,
A-coded, Cable length: 5 m
Key Commercial Data
Packing unit
Minimum order quantity
GTIN
GTIN
Custom tariff number
Note
4046356672467
85444290
Made to Order (non-returnable)
1 STK
50 STK
Technical data
Dimensions
Length of cable
5m
Ambient conditions
Degree of protection
IP65
IP67
IP68
General
Rated current at 40°C
Rated voltage
Number of positions
Insulation resistance
Coding
Status display
Overvoltage category
Degree of pollution
4A
60 V
5
≥ 100 MΩ
A - standard
No
II
3
11/13/2016 Page 1 / 3
https://www.phoenixcontact.com/hq/products/1403886
Sensor/Actuator cable - SAC-5P-M12MS/ 5,0-PVC/M12FS - 1403886
Technical data
General
Insertion/withdrawal cycles
≥ 100
Material
Flammability rating according to UL 94
Contact material
Contact surface material
Contact carrier material
Material of grip body
Material, knurls
Sealing material
HB
CuSn
Ni/Au
TPU GF
TPU, hardly inflammable, self-extinguishing
Zinc die-cast, nickel-plated
NBR
Standards and Regulations
Resistance to oil
Flame resistance
Flammability rating according to UL 94
in accordance with DIN EN 60811-2-1
As per UL-Style 2464
HB
Cable
Cable type
Cable type (abbreviation)
Cable abbreviation
UL AWM style
Conductor cross section
AWG signal line
Conductor structure signal line
Core diameter including insulation
Thickness, insulation
Wire colors
Overall twist
External sheath, color
Outer sheath thickness
External cable diameter D
Minimum bending radius, fixed installation
Minimum bending radius, flexible installation
Cable weight
Outer sheath, material
Material conductor insulation
Conductor material
Insulation resistance
Conductor resistance
Nominal voltage, cable
Test voltage, cable
Flame resistance
PVC black
PVC
LiYY
2464 / 1729 (80°C/300 V)
5x 0.34 mm² (Signal line)
22
19x 0.15 mm
1.26 mm ±0.05 mm
≥ 0.23 mm (Core insulation)
brown, white, blue, black, green-yellow
5 wires around filler to the core
black RAL 9005
≥ 0.76 mm
5 mm ±0.15 mm
5xD
10 x D
51 kg/km
PVC
PVC
Bare Cu litz wires
≥ 200 MΩ*km (at 20 °C)
max. 57 Ω/km (at 20 °C)
≤ 300 V
≥ 3000 V
As per UL-Style 2464
11/13/2016 Page 2 / 3
https://www.phoenixcontact.com/hq/products/1403886
Sensor/Actuator cable - SAC-5P-M12MS/ 5,0-PVC/M12FS - 1403886
Technical data
Cable
Ambient temperature (operation)
-40 °C ... 80 °C (cable, fixed installation)
-25 °C ... 80 °C (cable, flexible installation)
Drawings
Schematic diagram
4
5
3
Schematic diagram
3
5
4
1
2
2
1
Pin assignment M12 male connector, 5-pos., A-coded, male side
Pin assignment M12 socket, 5-pos., A-coded, socket side view
Cable cross section
Dimensional drawing
46,8
Ø14,8
PVC black [PVC]
M12 x 1 plug, straight
Dimensional drawing
1
44
2
M12
Circuit diagram
Ø11
1
2
4
3
5
Ø14,8
Ø11
M12
4
3
5
M12 x 1 socket, straight
Contact assignment of the M12 plug and the M12 socket