Description
stat-A-REST™ Foot Grounders provide contact with ESD
United States of America
flooring providing a more continuous and reliable path-to-ground to remove
electrostatic charges. stat-A-REST™ are easier to install than most foot grounders,
designed to be used on standard shoes placing the grounding tab in the shoe under the
foot. It is a suitable ESD footwear component in a Footwear / Flooring System meeting
the ANSI/ESD S20.20 required limits < 1 x 10
9
ohms (footwear) per ESD SP9.2 and ESD
TR53 and Footwear / Flooring requirements of < 3.5 x 10
7
ohms per ANSI/ESD STM97.1
and < 100 volts per ANSI/ESD STM97.2.
Made in the
Components
A. Non-Marring Thermoplastic Elastomer (TPE)
B. 30 Inch Conductive 8-Strand Nylon Polyester Grounding Tab
C. Size molded on bottom of unit
Electrical Properties
Property
Point to Groundable
Point Resistance:
Test Method
ANSI/ESD STM97.1, ESD SP9.2, ESD TR53
Value
< 1 x 10
9
ohms
C
See independent test lab report
here.
Specifications
B
Side View
A
Bottom View
Item
Size
Length
Width
Shoe Size Women
Shoe Size Men
Shoe Size EU
Sold in pairs
SAR-S
Small
9.5"
3.25"
5-8
4-6
35-38
SAR-M
Medium
10.25"
3.75"
8.5-10.5
6.5-8.5
39-43
SAR-L
Large
11"
4.375"
11-13.5
9-12
44-46
SAR-XL
XLarge
11.75"
4.625"
13.5+
12.5-14.5
46-48
RoHS 2, REACH, and Conflict Minerals Statement
None of the RoHS 2 restricted materials or REACH substances of very high concern as
of 2014/12/17, or Conflict Minerals are intentionally added in manufacturing this product.
Ref: European Union Directive 2011/65/EU and Regulation (EC) No. 1907/2006/CE.
See
SCS Warranty, Limitation of Liability and Remedies
“All personnel shall be bonded or electrically connected to the grounding / equipotential
bonding system when handling ESDS [ESD sensitive] items. …For standing operations,
personnel shall be grounded via a wrist strap or by a footwear/flooring system.” [ANSI/ESD
S20.20 section 8.2 Personnel Grounding]
“If the contact area between the bottom of the foot and the floor is not continuous, charge
generation may occur; especially when a person is walking. Heel straps must be worn on
both feet to minimize the amount of time that the body of the person is isolated from ground
while walking.” [ESD Handbook ESD TR20.20 section 5.2.3 Flooring-Footwear System]
*Patent US008189318B2
Unless otherwise noted, tolerance +/- 10%
Specifications and procedures subject to change without notice.
stat-A-REST™ FOOT GROUNDERS
926 JR Industrial Drive, Sanford, NC 27332
WEB SITE:
StaticControl.com
PHONE (919) 718-0000
DRAWING
NUMBER
SAR-S
DATE
July
2015
©
2015 DESCO INDUSTRIES INC.
Employee Owned