产品描述Industrial Pressure Sensors Pressure sensor 160 bar, 0.5-4.5 VDC, fluorocarbon FKM (Viton), G1/4"A DIN 3852-E, compatible with DIN 175301-803 A (18mm) with matting connector
Industrial Pressure Sensors Pressure sensor 160 bar, 0.5-4.5 VDC, fluorocarbon FKM (Viton), G1/4"A DIN 3852-E, compatible with DIN 175301-803 A (18mm) with matting connector
Packard Electric Metri-Pack 150 Series, M12 - 4 Pole *
G1/4A DIN 3852-E, G1/4A DIN 3852-A *
304 Stainless Steel (1.4301)
4 - 20 mA, 0.5 - 4.5 VDC, 0 - 5 VDC, 0 - 10 VDC
Attributes
Hermetically Sealed
Rugged & Durable
Compact & Light-weight
Resistant to Chemical Attack
Superior Long-Term Stability & Repeatability
Outstanding Shock & Vibration Performance
Typical Applications
Compressors
Hydraulic Systems
Agricultural Equipment
Construction Equipment
Heat Pumps
Wind Energy
HVAC Systems
Chemical Industry
Description
The PTE5000 utilizes Kavlico’s thin film strain gauge sensing technology, incorporating an hermetically
sealed design with no internal sealing required. Designed for harsh environments, a rugged 304 stainless
steel housing surrounds the PTE5000 transducer.
The PTE5000’s small, compact design as well as its low overall weight makes it ideal
for applications with spacing and weight limitations. This easy-to-use sensor is media
resistant, which allows it to be used for a broad range of liquid and gaseous media. It
can be used at high operating temperatures and has internal temperature compensation.
Highly reliable, the PTE5000 provides accurate, high pressure measurements every time.
www.kavlico.com
Technical Specifications
Pressure Ranges
from 0 to …
Proof pressure
Burst pressure
bar (gage)
bar (gage)
bar (gage)
6
12
60
10
20
100
16
32
160
25
50
200
40
80
320
60
120
480
100
200
600
160
320
960
250
500
1000
400
800
1600
600
1200
2400
Physical
Operating Life Cycle
Vibration Resistance
Shock Resistance
Drop Test
Weight
Ingress Protection
Medium Temperature
Storage Temperature
Media
*4
min. 10 million full pressure cycles over the full range
IEC 60068-2-64 (RANDOM) 20 PSD
25 g minimum according to DIN EN 60068-2-27
1 meter drop on concrete as per SAE J1455 / DIN EN 60068-2-3-1
≤
50 grams (without mating connector)
IP 65 or IP67 - depending on electrical connector
-30°C to + 120°C (others on request)
-30°C to + 100°C (dep. on electrical connector & external seal ring capability)
*4
All class II fluids and gases compatible with stainless steel 304 (1.4301)
Environmental Temperature
-30°C to + 100°C (dep. on electrical connector & external seal ring capability)
*4
For more details see How to Order
Performance
Accuracy
*1
Non-linearity
*2
Non-repeatability
1-year stability
Temp. Coefficients - Zero
Temp. Coefficients - Span
*1
*2
≤
0.5 % of span
*3
0.2 % of span
*3
0.1 % of span
*3
0.2 % of span
*3
0.2 % of span / 10 K within temperature range 0°C to + 80°C.2 %
0.2 % of span / 10 K within temperature range 0°C to + 80°C.2 %
Including non-linearity, hysteresis, non-repeatability, zero point and full scale error (corresponds to error of measurement per IEC 61298-2). Adjusted in vertical mounting position with pressure port down.
BFSL according to IEC 61298-2 reference conditions to EN 61298-1
Others on request
*3
www.kavlico.com
Data Sheet PTE5000
2
Electrical
0.5…4.5 VDC
ratiometric
5 VDC ± 5%
≤
25 mW
min. 6 VDC
Yes
*5
500 VDC
Yes
*6
Output Signal
Operating Supply Signal
Power Consumption
Overvoltage Protection
Short-circuit Proofness
Insulation Voltage
Load
Response Time
*5
4…20 mA
8-30 VDC
≤
600 mW
min. 33 VDC
not applicable
500 VDC
0…5 VDC
8-30 VDC
≤
600 mW
min. 33 VDC
Yes
*5
500 VDC
Yes
*6
≥
4.7 kΩ
0…10 VDC
14-30 VDC
≤
600 mW
min. 33 VDC
Yes
*5
500 VDC
Yes
*6
≥
4.7 kΩ
Reverse Polarity Protection
Yes
*6
≤
(Vsup-8 VDC)/(0.02 A) [Ω]
≥
4.7 kΩ
≤
5 ms max. to 63% of full scale pressure with step change on input
for min. 3 intervals at 5 minutes each
for min. 10 seconds on assigned pins
*6
Approvals & Certificates
Pressure equipment directive 97/23/EC
EMC directive 2004/108/EEC, EN 61 326 Emission (Group 1, Class B)
and Immunity (industrial locations), EMI, ESD protected
Standard(s) for Safety: Electrical Equipment for Measurement, Control and
Laboratory Use - UL 61010-1
2011/65/EU ROHS Directive
CE Compliance
UL
ROHS
www.kavlico.com
Data Sheet PTE5000
3
Dimensions
Pressure Sensor with Electrical Connection
Dimensions in mm [Inch]
M12 Pin Call Outs
Output
4-20 mA
0.5-4.5 VDC ratiometric
0-5 VDC
0-10 VDC
Pin 1
Vsup
Vsup
Vsup
Vsup
Pin 2
...
...
...
...
Pin 3
lout
Vout
Vout
Vout
Pin 4
...
GND
GND
GND
18 mm Pin Call Outs
Output
4-20 mA
0.5-4.5 VDC ratiometric
0-5 VDC
0-10 VDC
Pin 1
Vsup
Vsup
Vsup
Vsup
Pin 2
lout
Vout
Vout
Vout
Pin 3
...
GND
GND
GND
Pin 4
...
...
...
...
Packard (metri-pack 150) Pin Call Outs
Output
4-20 mA
0.5-4.5 VDC ratiometric
0-5 VDC
0-10 VDC
Pin 1
lout
GND
GND
GND
Pin 2
Vsup
Vsup
Vsup
Vsup
Pin 3
...
Vout
Vout
Vout
9.4 mm Pin Call Outs
Output
4-20 mA
0.5-4.5 VDC ratiometric
0-5 VDC
0-10 VDC
Pin 1
Vsup
Vsup
Vsup
Vsup
Pin 2
lout
Vout
Vout
Vout
Pin 3
...
GND
GND
GND
Pin 4
...
...
...
...
www.kavlico.com
Data Sheet PTE5000
4
Pressure Connections and Recommended Installation Torque
SMT贴片机是表面贴装技术(Surface Mount Technology)中的重要设备,它的性能状态对电子制造的质量和效率有着决定性的影响。因此,对SMT贴片机的主要指标性能进行定期检测非常重要。以下是一些主要的检测项目: 定位精度:定位精度是SMT贴片机的核心性能指标,它直接影响到贴片的准确性。通常,我们通过重复测量贴片机在X、Y轴上的移动误差来检测其定位精度。 贴片速度:贴片速度...[详细]
与云数据库相比,小型计算机是专门为网络边缘的去中心化坚固计算而构建的。通过将应用程序、分析和处理服务移动到更靠近数据生成源的位置,业务运营可以获得改进的实时计算应用程序性能。 l 从奔腾到酷睿i5的可扩展CPU性能 l 智能电源点火管理和CAN总线网络支持 l 无线局域网和广域网LTE连接 l 丰富的I/O可扩展性,包括PoE、PCI、PCIe、COM l 适用于宽工作温度和宽电压输入的坚固...[详细]
我最近在《华尔街日报》看到一篇题为“我们需要能维修自己的电子小玩意儿的权利(We need the right to repair our gadgets)”的文章(参考原文:),作者对于众多电子产品看来是“有计画的废弃(planned obsolescence)”之现象非常愤怒,认为大众应该要求电子产品可以被维修。 但实际的情况是,举例来说,家家都有的电视机如果故障了,修理费用可能...[详细]