Safety Light Curtains
F3SJ-B
Safety Light Curtains
•
•
•
•
•
•
•
•
Fast and easy installation
Resolution: 25 mm (1.01 in.)
Range: 7 m (23 ft.)
Protected heights: 185 to 2065 mm (7.28 to 81.26 in.)
Very compact size: 30 x 30 mm (1.18 x 1.18 in.)
Cascaded designs possible – 3 segments
Simple muting
Cross-talk prevention
Description
In addition to the simple functions inherited from the EASY type, such as global support, easy-to-view indicators, the BASIC type
includes series connection and simple muting functions . This enables the BASIC type to satisfy installations that require multiple safety
light curtains.
Up to three sets connected in a series
It is possible to con-
nect up to three sets of
safety light curtains in se-
ries. These sensors can
be placed in a U-shaped
or L-shaped pattern with
a single power line, thus
requiring less wiring.
Series
Connection
Functions inherited from the EASY type
Simple functions such as universal power voltage specifica-
tion, easy-to-view diagnostics, a fixed response time have been
inherited from the EASY type, As a result, expect reduced
work-hours at each stage of use, from design and installation to
operation.
Global
Support
Easy-to-View
Diagnostics
Instant visibility of process trouble during muting
The BASIC type includes a muting function which temporar-
ily disables the safety light curtain when a workpiece passes
through. In the event of
any trouble occur-
ring, the error can be
instantly recognized
from the pattern of the
LED indicators, allow-
ing for a fast solution.
Simple
Muting
1
D-27
F3SJ-B
Safety Light Curtains
Specifications
Main Units
F3SJ-B
££££
P25
Sensor type
Setting tool connection *1
Safety category
Detection capability
Beam gap (P)
Number of beams (n)
Protective height (PH)
Lens diameter
Operating range *2
Response time
(under stable light
incident condition)
Startup waiting time
Power supply voltage (Vs)
Consumption current
(no load)
Emitter
Receiver
ON to OFF
OFF to ON
Type 4 safety light curtain
Parameter settings: Not available
Safety purpose of category 4, 3, 2, 1, or B
Opaque objects 25 mm in diameter
20 mm
8 to 102
185 to 2,065 mm
Diameter 5 mm
0.2 to 7 m
15 ms max. (response time at 1 set connection, series connection of 2 sets or 3 sets)
70 ms max. (response time at 1 set connection, series connection of 2 sets or 3 sets)
2 s max.
SELV/PELV 24 VDC±20% (ripple p-p 10% max.)
Up to 22 beams: 52 mA max., 26 to 42 beams: 68 mA max., 46 to 62 beams: 75 mA max.,
66 to 82 beams: 88 mA max., 86 to 102 beams: 101 mA max.
Up to 22 beams: 45 mA max., 26 to 42 beams: 50 mA max., 46 to 62 beams: 46 mA max.,
66 to 82 beams: 61 mA max., 86 to 102 beams: 67 mA max.
Infrared LED (870 nm)
Based on IEC 61496-2. Within ±2.5° for both emitter and receiver when the detection distance is 3 m or over
Two PNP transistor outputs, load current 200 mA max., residual voltage 2 V max. (except for voltage drop due
to cable extension), Leakage current 1 mA max., load inductance 2.2 H max. *3
Maximum capacity load 1 µF *4
Two PNP transistor outputs, load current 100 mA max., residual voltage 2 V max. (except for voltage drop due
to cable extension), leak current 1 mA max.
Safety output: On when receiving light
Auxiliary output:
– Reverse output of safety output for a basic system
– ON when muting/override for a muting system
ON voltage: Vs-3 V to Vs *5
OFF voltage: 0 V to 1/2 Vs or open
Mutual interference prevention algorithm prevents interference in up to 3 sets.
Time division emission by series connection
• Number of connections: up to 3 sets (between F3SJ-Bs only) Other models cannot be connected.
• Total number of beams: up to 192 beams
• Maximum cable length for 2 sets: no longer than 7 m
• Self test (at power-ON and at power distribution)
• External test (emission stop function by test input)
• Interlock (basic system)
• External device monitoring (basic system)
• Muting (muting system)
• Override (muting system)
Connector method (M12, 8-pin)
Output short-circuit protection, and power supply reverse polarity protection
Operating: -10 to 55°C (non-freezing), Storage: -25 to 70°C
Operating: 35% to 85% (no condensation), Storage: 35% to 95% RH
Incandescent lamp: 3,000 lx max., Sunlight: 10,000 lx max.
20 MΩ min. (at 500 VDC)
1,000 VAC 50/60 Hz, 1 min
IP65 (IEC 60529)
Malfunction: 10 to 55 Hz, Multiple amplitude of 0.7 mm, 20 sweeps in X, Y, and Z directions
Malfunction: 100 m/s2, 1,000 times each in X, Y, and Z directions
Pollution degree 3 (IEC 60664-1)
(Continued on next page)
*1. Do not use the Support Software and Setting Console for F3SJ-A.
Operation cannot be guaranteed.
*2. Use of the Spatter Protection Cover causes a 10% maximum sensing
distance attenuation.
*3. The load inductance is the maximum value when the safety output
frequently repeats ON and OFF. When you use the safety output at 4 Hz
or less, the usable load inductance becomes larger.
*4. These values must be taken into consideration when connecting
elements including a capacitive load such as capacitor.
*5. The Vs indicates a voltage value in your environment.
*7. Mounting brackets are sold separately.
Light source (emitted wavelength)
Effective aperture angle (EAA)
Safety outputs (OSSD)
Auxiliary output 1
Output operation mode
Input voltage
Mutual interference prevention function
Series connection
Test function
Safety-related functions
Connection type
Protection circuit
Ambient temperature
Ambient humidity
Operating ambient light intensity
Insulation resistance
Dielectric strength
Degree of protection
Vibration resistance
Shock resistance
Pollution degree
D-28
2
F3SJ-B
Safety Light Curtains
Specifications (continued)
Main Units
F3SJ-B
££££
P25 (continued)
Connection method: Prewired connector cable,
cable length 0.3 m, connector type (M12, 8-pin),
connector: IP67 rated (when mated)
Number of wires: Emitter: 8 wires
Cable diameter: Dia. 6 mm
Allowable bending radius: R5 mm
30 m max.
Case: Aluminum
Cap: ABS resin, PBT
Optical cover: PMMA resin (acrylic)
Cable: Oil resistant PVC
Weight (g) = (protective height) x 2.7 + 500
Test rod, User’s Manual (CD-ROM) *7
IEC 61496-1, EN 61496-1 UL 61496-1, Type 4
ESPE (Electro-Sensitive Protective Equipment)
IEC 61496-2, CLC/TS 61496-2, UL 61496-2,
Type 4 AOPD (Active Opto-electronic Protective
Devices)
IEC 61508-1 to -3, EN 61508-1 to -3 SIL3
IEC 13849-1: 2006, EN ISO 13849-1: 2008 (PLe,
Cat.4)
UL 508, UL 1998, CAN/CSA C22.2 No.14, CAN/
CSA C22.2 No.0.8
Accessories
Control Unit
F3SP-B1P
Applicable sensor
Power supply voltage
Power supply consumption
Operation time
Response time
Number of
contacts
Rated load
Rated current
Connection Between sensors
type
Others
Weight (packed state)
Accessories
F3SJ-B/A (Only for PNP output type)*
24 VDC ±10%
DC1.7 W max. (not including sensor’s
current consumption)
100 ms max. (not including sensor’s
response time)
100 ms max. (not including sensor’s
response time)
3NO + 1NC
250 VAC 5 A (cos = 1), 30 VDC 5 A L/R
= 0 ms
5A
M12 connector (8-pin)
Terminal block
Approx. 280 g
Instruction manual
Power cable
Extension cable
Material
Weight (packed state)
Accessories
Relay
output
Applicable standards
*NPN output type cannot be connected. Also, the system cannot be used
as a muting system.
Applications
Selecting the Best Configuration
Space Efficient and Low Cost
The built-in external device monitoring function
eliminates the need for a safety relay unit.
No Safety Relay Unit
F39-JD®A
G7SA
Contactor
Motor
Reduced Wiring and Easy Maintenance
Cables with connectors on both ends simplify
connections and prevent wiring errors.
Connector Type
F39-JD®B
F3SP-B1P
Dedicated controller
Contactor
Motor
3
D-29
F3SJ-B
Safety Light Curtains
Wiring
Basic Wiring Diagram
Wiring when using manual reset mode, external device monitoring
Receiver
F39-JD@A-D
(Gray) Communication line (+)
(Pink)
Communication line (−)
External device
monitoring input (Red)
Not Used (Red)
0 V (Blue)
0 V (Blue)
Shield
Interlock select input (White)
+24 V (Brown)
+24 V (Brown)
Auxiliary output (Yellow)
Safety output 2 (White)
Safety output 1 (Black)
Test input (Black)
Reset input (Yellow)
Shield
KM1
K1
KM2
+24 VDC
Power
supply
0V
Emitter
F39-JD@A-L
S1
S2
KM1
KM2
S1
S2
KM1, KM2
K1
: External test switch (connect to 0 V if a switch is not required)
: Interlock/lockout reset switch
: Safety relay with force-guided contact (G7SA) or magnetic contactor
: Load or PLC, etc. (for monitoring)
Wiring for auto reset mode and deactivated external device monitoring
Receiver
F39-JD@A-D
(Gray) Communication line (+)
(Pink)
Communication line (−)
External device
monitoring input (Red)
Shield
0 V (Blue)
0 V (Blue)
Not Used (Red)
Interlock select input (White)
+24 V (Brown)
+24 V (Brown)
Safety output 2 (White)
Safety output 1 (Black)
Test input (Black)
Reset input (Yellow)
Auxiliary
output (Yellow)
Shield
K1
Emitter
F39-JD@A-L
S1
S2
KM1
KM2
+24 VDC
Power
supply
0V
S1
S2
KM1, KM2
K1
: External test switch (connect to 0 V if a switch is not required)
: Lockout reset switch
: Safety relay with force-guided contact (G7SA) or magnetic contactor
: Load or PLC, etc. (for monitoring)
D-30
4
F3SJ-B
Safety Light Curtains
Dimensions
F3SJ-B/F3SJ-E Dimensions
The dimensions of the F3SJ-B and F3SJ-E are the same except for connector cables and cable leads.
(mm)
Main Units
Mounting Top/Bottom and Intermediate Brackets
Backside mounting
7.5
Top/Bottom Bracket
(F39-LJB1)
43
18.3
2
13
6.5
30
19
dia.9
4-M5
19
5.9
2-M8
Mounting screw holes
C (protective height): 4-digit number in the table
A = C + 69, B = C + 42.2
D = C - 45, E = See table below, P = 20
Protective
height
Number of
intermediate
brackets
0
1
2
E
—
C/2 max.
C/3 max.
30
30
22
7
C (Protective height)
D
53
42
5.5
P (beam gap)
30
185 to 1,105
1,185 to 1,345
22
22
Intermediate
Bracket
(F39-LJB2)
1,425 to 2,065
C
B
C
42
B
A
B
2-M5
E
E
2-M5
E
Top/Bottom
Bracket
(F39-LJB1)
34.5
22.5
42
13.4
<M5 screw fixed>
45
<M8 screw fixed>
Side mounting
6.5
7.5
Top/Bottom dia.9
Bracket
(F39-LJB1)
18.3
30
19
46
30
34.5
19
4-M5
5.9
Mounting screw holes
5.9
2-M8
C (protective height): 4-digit number in the table
A = C + 69, B = C + 42.2
D = C - 45, E = See table below, P = 20
Protective
height
185 to 1,105
1,185 to 1,345
Number of
intermediate
brackets
0
1
2
E
—
C/2 max.
C/3 max.
30
Intermediate
Bracket
(F39-LJB2)
7
22
C (Protective height)
22
1,425 to 2,065
C
B
C
53
42
5.5
B
A
B
2-M5
E
42
2-M5
E
5.9
34
42
Top/Bottom
Bracket
(F39-LJB1)
E
16
22.5
12
13.4
42
D
<M5 screw fixed>
<M8 screw fixed>
Dimensions of top/bottom bracket
for F39-LJB1
45
34.5
18.3
dia.9
7.5
4.3
19
6.5
16
30
2
Material : Stainless
43
5
D-31